ACURITE 06004 5-in-1 Weather Sensor Instruction Manual
- June 7, 2024
- Acurite
Table of Contents
Instruction Manual
AcuRite Iris ™(5-in-1) Weather Sensor
(Single Solar Panel)
model 06004
IMPORTANT
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
PRODUCT REGISTRATION
Register online to receive 1-year warranty protection
www.acurite.com/product-registration
Questions? Visit www.acurite.com/support
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Features & Benefits
AcuRite Iris SENSOR
-
Rainfall Collector Funnel
-
Solar Cell Panel
Converts sunlight into power to run the internal aspirating fan.
Internal Aspirating Fan
(not shown)
Draws ambient air into the sensor to reduce solar radiation heating, resulting in more accurate temperature measurement. -
A-B-C Switch
ID code that must match display’s A-B-C switch to ensure units synchronize. -
Battery Compartment
-
Temperature & Humidity Sensors
(internal)
-
Mounting Point
-
Wind Speed Anemometer
-
Wind Direction Vane
-
Mounting Bracket
-
Mounting Hardware
Includes 5 anchors & the following screws:
Qty Diameter Length
5 #4 3/4”
1 #4 1/2”
1 #6 1/2”
-
Debris Filter
Pre-installed to prevent debris from entering the rain gauge.
SETUP
AcuRite Iris Sensor Setup
-
Set the A-B-C Switch
Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select the same letter choice for both the sensor and the companion unit (not included) in order for the units to synchronize. -
Install or Replace Batteries
Batteries MUST be installed for this product to operate. AcuRite recommends high-quality alkaline or lithium batteries for the best product performance. Heavy-duty or rechargeable batteries are not recommended. The AcuRite Iris sensor requires lithium batteries in low-temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the AcuRite Iris sensor for temperatures below -4ºF / -20ºC. -
Remove Rain Gauge Stabilizer
Locate and remove the rain gauge stabilizer (plastic tab) taped into the bottom of the sensor. The rain gauge will not function until this is removed.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE
WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior
to battery installation. Remove batteries from equipment that will not be used
for an extended period of time. Follow the polarity (+/-) diagram in the
battery compartment. Promptly remove dead batteries from the device. Dispose
of used batteries properly. Only batteries of the same or equivalent type as
recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose
of batteries in fire, as batteries may explode or leak. DO NOT mix old and new
batteries or types of batteries (alkaline/standard). DO NOT use rechargeable
batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit
the supply terminals.
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper
placement of the sensor is critical to the accuracy and performance of this
product.
AcuRite Iris Sensor Placement
The AcuRite Iris sensor is designed to remain outdoors all year long.
Choose an open location with no obstructions above or around the sensor for
the most accurate measurements.
Important Placement Guidelines
The sensor must be within 330 feet (100 m) of the companion unit (not
included).
MAXIMIZE WIRELESS RANGE
Place sensor away from large metallic items, thick walls, metal surfaces, or
other objects that may limit wireless communication.
LOCATE AWAY FROM HEAT SOURCES
Position sensor away from heaters, air conditioners, chimneys, exhaust vents,
asphalt and concrete (surfaces that radiate heat).
LOCATE AWAY FROM HUMIDITY SOURCES
Avoid installing the sensor near pools, spas, or other bodies of water. Water
sources may impact humidity accuracy.
LOCATE AWAY FROM SPRINKLER HEADS
DO NOT install the sensor where it will be sprayed by a sprinkler system. This
may force water inside the sensor.
LOCATE AWAY FROM WIND & RAIN OBSTRUCTIONS
DO NOT mount the sensor with obstructions around it. Consider a location that
is a wide-open area, with few structures around to ensure accurate wind
measurement.
AcuRite Iris Sensor Installation Guidelines
INSTALLATION HEIGH T Mount the sensor at least 5 feet (1.5 meters) off
the ground in an open area. Higher is better for wind measurement- the
National Weather Service recommends 33 feet (10 meters) high!
MOUNTING OPTIONS The included mounting bracket is designed to screw
directly onto wooden posts or surfaces that are 2”x 4” or larger. The sensor
can also be mounted directly to 3/4” steel pipe (available at hardware stores
and home centers).
LEVEL INSTALLATION Use the bubble level on the top of the sensor to
ensure a level installation for accurate wind and rain
measurement.
SOLAR CELL INSTALLATION Install the sensor with the solar cell facing
SOUTH. This ensures the cell receives as much sun as possible and orients wind
direction.
AcuRite Iris Sensor Installation
- Fasten mounting base (included) to a post or pole (not included) using the 4 longer screws included in the hardware bag.
- Insert the mounting base into the hole on the bottom of the sensor. (1.5 meters)
- Make sure the arrows on the top of the sensor are pointed in the proper direction and the a bubble level is centered. The solar cell should be facing south to properly orient the wind direction.
- Fasten the sensor into the mounting base using the 2 shorter screws included in the hardware bag.
The AcuRite Iris sensor is now ready to use.
Basic Setup is Complete
The AcuRite Iris sensor will now synchronize with the companion unit. It may take a few minutes for synchronization to complete.
Calibrate the Rain Gauge
The rain gauge on the AcuRite Iris sensor can be calibrated to improve
accuracy.
Items Needed: AcuRite Iris sensor, companion unit, plastic cup, pin,
screwdriver
- First, ensure the AcuRite Iris sensor is perfectly level using a built-in bubble level.
- Use compatible companion unit or AcuRite software to monitor during calibration.
- Make a pinhole in the bottom of a plastic cup. Hold the cup over the rain gauge and fill it with exactly 1 cup (8oz) of water, allowing the water to drip into the rain gauge. You should hear the internal buckets tip and see water drain through the rain gauge.
- A few seconds after each bucket tip, the companion unit displays rainfall in approximately 0.01” or more increments.
- The cup of water should take more than 20 minutes to empty; a quicker period will result in an inaccurate calibration. Try to simulate a normal steady rainfall. When the cup is empty of water, the companion unit should register 1.06”
Tips
-
There should be nearly an equal number of water drops (about 25 water drops) between bucket tips. If not, adjust the calibration screws on the bottom of the AcuRite Iris sensor until an equal number of water drops are tipping the buckets.
Adjustment
If the rain gauge doesn’t register close to 1.06”, make an EQUAL adjustment to the two calibration screws on the bottom of the AcuRite Iris sensor. Turning screws clockwise increases rainfall; counterclockwise decreases rainfall. -
To adjust the rainfall reading by 2% turn both screws 1/8 of a turn.
-
To adjust the rainfall reading by 4% turn both screws 1/4 of a turn.
-
To adjust the rainfall reading by 8% turn both screws 1/2 of a turn.
Specifications
TEMPERATURE RANGE | Outdoor: -40°F to 158°F; -40°C to 70°C |
---|---|
HUMIDITY RANGE | Outdoor: 1% to 99% |
WIND SPEED | 0 to 99 mph; 0 to 159 kph; 0 to 86 knots |
WIND DIRECTION INDICATORS | 16 points |
RAINFALL | 0.01 inches (0.25 mm) and up |
WIRELESS RANGE | 330 ft / 100 m depending on home construction materials |
OPERATING FREQUENCY | 433 MHz |
POWER | 4 x AA alkaline or lithium batteries |
DATA REPORTING | Wind Speed: 18 second updates; Direction: 36 second updates |
Outdoor temperature & humidity: 36 second updates
Customer Support
AcuRite customer support is committed to providing you with best-in-class
service. For assistance, please have the model number of this product
available and contact us in any of the following ways:
Chat with our support team at www.acurite.com/support
Email us at support@chaney-inst.com
► Installation Videos
► Instruction Manuals
► Replacement Parts
Limited 1-Year Warranty
AcuRite is a wholly-owned subsidiary of Chaney Instrument Company. For
purchases of AcuRite products, AcuRite provides the benefits and services set
forth herein.
For purchases of Chaney products, Chaney provides the benefits and services
set forth herein. We warrant that all products we manufacture under this
warranty are of good material and workmanship and, when properly installed and
operated, will be free of defects for a period of one year from the date of
purchase.
Any product which, under normal use and service, is proven to breach the
warranty contained herein within ONE YEAR from date of sale will, upon
examination by us, and at our sole option, be repaired or replaced by us.
Transportation costs and charges for returned goods shall be paid for by the
purchaser. We hereby disclaim all responsibility for such transportation costs
and charges.
This warranty will not be breached, and we will give no credit for products
that have received normal wear and tear not affecting the functionality of the
product, been damaged (including by acts of nature), tampered, abused,
improperly installed, or repaired or altered by others than our authorized
representatives.
Remedy for breach of this warranty is limited to repair or replacement of the
defective item(s). If we determine that repair or replacement is not feasible,
we may, at our option, refund the amount of the original purchase price.
THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY FOR THE PRODUCTS AND IS
EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ALL OTHER
WARRANTIES OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN ARE HEREBY
EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF
MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
We expressly disclaim all liability for special, consequential, or incidental
damages, whether arising in tort or by contract from any breach of this
warranty. Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion may not apply
to you.
We further disclaim liability from personal injury relating to its products to
the extent permitted by law. By acceptance of any of our products, the
purchaser assumes all liability for the consequences arising from their use or
misuse. No person, firm or corporation is authorized to bind us to any other
obligation or liability in connection with the sale of our products.
Furthermore, no person, firm, or corporation is authorized to modify or waive
the terms of this warranty unless done in writing and signed by a duly
authorized agent of ours.
In no case shall our liability for any claim relating to our products, your
purchase or your use thereof, exceed the original purchase price paid for the
product.
Applicability of Policy
This Return, Refund, and Warranty Policy apply only to purchases made in the
United States and Canada. For purchases made in a country other than the
United States or Canada, please consult the policies applicable to the country
in which you made your purchase. Additionally, this Policy applies only to the
original purchaser of our products. We do cannot and do not offer any return,
refund, or warranty services if you buy products used or from resale sites
such as eBay or Craigslist.
Governing Law
This Return, Refund, and Warranty Policy is governed by the laws of the United
States and the State of Wisconsin. Any dispute relating to
this Policy shall be brought exclusively in the federal or state courts having
jurisdiction in Walworth County, Wisconsin; and purchaser
consents to jurisdiction within the State of Wisconsin.
Printed in China
06004RMA1 INST 080621
© Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology. Visit www.acurite.com/patents for details.