AcuRite 06096 Display for 5-in-1 Weather Sensor Instruction Manual
- June 7, 2024
- Acurite
Table of Contents
Instruction Manual
Display for 5-in-1 Weather Sensor
model 06096
Package Contents
- Display with Tabletop Stand
- Power Adapter
- Instruction Manual
This product requires an AcuRite 5-in-1 Weather Sensor (sold separately) to be operational.
Questions? Contact Customer Support at
www.AcuRite.com/support or email support
@chaney-inst.com
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Features & Benefits
Display
-
5-in-1 Sensor Signal Strength
-
Current Outdoor Humidity
The arrow icon indicates direction humidity is trending. -
High/Low Humidity Records
Highest and lowest outdoor humidity recorded since midnight. -
Average Wind Speed
Average wind speed over the past 2 minutes. -
Peak Wind Speed
Highest speed from the last 60 minutes. -
Icon
Indicates an alarm has been activated. -
Rainfall History
Displays historical rainfall totals (see page 9). -
Current Indoor Temperature
The arrow icon indicates direction temperature is trending. -
Humidity Level Indicator
Indicates a high, low, or ideal humidity comfort level. -
Current Indoor Humidity
The arrow icon indicates direction humidity is trending. -
Date
-
Clock
-
Button
For setup preferences. -
Button
For momentary backlight and dimmer settings. -
Button
For setup preferences and to cycle through rainfall history. -
Button
For setup preferences and to view all-time records. -
Button
For alarm setup preferences. -
Icon
Indicates display is in auto-dimming brightness mode (see page 6). -
Moon Phase
-
Barometric Pressure
Arrow icon indicates direction pressure is trending. -
12 to 24 Hour Weather Forecast
Self-Calibrating Forecasting pulls data from your 5-in-1 sensor to generate your personal forecast. -
Month/Week/Today Rainfall
-
Current Wind Speed
-
Current Wind Direction
-
Seasonal Display
Heat Index calculation displays when the temperature is 80°F (27°C) or higher.
Dew Point calculation displays when the temperature is 79°F (26°C) or below.
Wind chill calculation displays when the temperature is 40°F (4°C) or lower. -
High/Low-Temperature Records
The highest and lowest outdoor temperature was recorded since midnight. -
Previous 2 Wind Directions
-
Current Outdoor Temperature
Arrow icon indicates direction temperature is trending.
Back of Display
BACK OF DISPLAY
-
Integrated Hang Hole
For easy wall mounting. -
Backup Battery Compartment
-
Plug-in for Power Adapter
-
A-B-C Switch
ID code that must match 5-in-1 sensorʼs A-B-C switch to ensure units synchronize. -
RESET BUTTON
Press and release to clear data.
Press and HOLD for the full reset to factory defaults. -
Power Adapter
-
Battery Compartment Cover
(not shown)
SETUP
Display Setup
-
Set the A-B-C Switch
Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B, or C.
You must select the same letter choices for both the display and the sensor in order for the units to synchronize. -
Install or Replace Backup Batteries (optional)
1. Remove the battery compartment cover.
2. Insert 3 x AAA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/–) diagram in the battery compartment.
3. Replace the battery cover. -
Plug-in Power Adapter
For the best performance, plug in the power adapter as the main power source for this product.
IMPORTANT: Batteries are a backup power source to preserve records in the event of a power outage. The power adapter is recommended as the primary power source to enjoy the full functionality of this product.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY
AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior
to battery installation. Remove batteries from equipment that will not be used
for an extended period of time. Follow the polarity (+/-) diagram in the
battery compartment. Promptly remove dead batteries from the device. Dispose
of used batteries properly. Only batteries of the same or equivalent type as
recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose
of batteries in fire, as batteries may explode or leak. DO NOT mix old and new
batteries or types of batteries (alkaline/standard). DO NOT use rechargeable
batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit
the supply terminals.
Set the Time, Date & Units
The display will automatically enter SET MODE after the unit has powered on.
Once in set mode, the preference you are currently setting will blink on the
display.
To adjust the currently selected (flashing} item, press and release the “ “ or
“ “ buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the “set ” button again to adjust
the next preference. The preference set order is as follows:
AUTO DST CHANGE (YES, NO)
CLOCK HOUR
CLOCK MINUTE
CALENDAR MONTH
CALENDAR DATE
CALENDAR YEAR
TEMPERATURE UNITS (°F or °C)
WIND SPEED UNITS (mph, km/h, knots)
RAINFALL UNITS (inches or mm)
PRESSURE UNITS (inHg or hPa)
If you live in an area that observes Daylight Saving Time, DST should be set to YES, even if it is not currently Daylight Saving Time.
You will automatically exit SET MODE if no buttons are pressed for 20 seconds.
Enter setup mode at any time by pressing the “ set ” button.
Display Backlight Settings
This weather stationʼs color display features three different lighting
settings:
High (100%) brightness, Medium (60%) brightness and Low (15%) brightness.
Using battery power alone, the backlight is available momentarily for 10
seconds by pressing the “ ” button.
When the display is powered with the power adapter, the backlight remains on
at 100% brightness. Press the “ ” button once to dim to 60% brightness. Press
again to dim to 15%. Press a 3rd time to enter “AUTO DIM” mode. The “ ” icon
appears to the left of the time to indicate that auto-dim mode is ON.
NOTE : Pressing and holding the “ ” button for 5 seconds will disable the
backlight. Once any button is pressed, the backlight will return to your
selected setting.
AUTO DIM MODE: Automatically adjusts display brightness based on time of day.
6:00 a.m. – 9:00 p.m. = 100% brightness
9:01 p.m. – 5:59 a.m.= 15% brightness
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper
placement of both the display and the sensor is critical to the accuracy and
performance of this unit.
Display Placement
Place the display in a dry area free of dirt and dust. The display stands
upright for tabletop use and is wall-mountable.
Important Placement Guidelines
- To ensure accurate temperature measurement, place units out of direct sunlight and away from any heat sources or vents.
- Display and sensor(s) must be within 330 feet (100 m) of each other.
- To maximize wireless range, place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.
- To prevent wireless interference, place units at least 3 feet (.9 m) away from electronic devices (TV, computer, microwave, radio, etc.).
OPERATION
Using the Professional Weather Center
Learning Mode
Self-Calibrating Forecasting use a unique algorithm to analyze changes in
pressure over a time period (called Learning Mode) to determine your altitude.
After 14 days, the “LEARNING” icon disappears from the display screen. At this
point, the self-calibrated pressure is tuned in to your location and the unit
is ready for superior weather prediction.
Weather Forecast
AcuRiteʼs patented Self-Calibrating Forecasting provides your personal
forecast of weather conditions for the next 12 to 24 hours by collecting data
from the sensor in your backyard.
It generates a forecast with pinpoint accuracy – personalized for your exact
location.
View the complete list of icons atwww.AcuRite.com/acurite-icons
Barometric Pressure
Subtle variations in barometric pressure greatly affect the weather. This
weather center displays the current pressure with an arrow icon to indicate
the direction the pressure is trending (FALLING, STEADY, or RISING).
Moon Phase
Track the phases of the moon, conveyed through simple lunar phase icons:
Rainfall Tracking
This weather station features enhanced tracking of historical rainfall data.
Rain accumulation data is displayed for the current day, week, or month (most
recent rainfall total). Press the “ ” button to review historical rainfall
records.
Records are shown in the following order: TODAY RAIN TOTAL
THIS WEEK RAIN TOTAL
THIS MONTH RAIN TOTAL
PREVIOUS MONTHLY TOTALS WITH RAIN (up to 12 months prior)
CURRENT YEAR TOTAL
PREVIOUS YEAR TOTAL
ALL-TIME TOTAL
Rainfall Data
TODAY
Displays rainfall recorded TODAY since 2:00 am, if applicable.| WEEK
If there hasnʼt been any rainfall today, the current weekʼs rainfall (Sunday
to Saturday) is displayed, if applicable.| MONTH
If there hasnʼt been any rainfall this week, the current monthʼs rainfall is
displayed.
Rainfall Records
Programmable Alarms
This display features programmable alarms that sound an alert to notify you
when a value (for outdoor temperature, humidity, wind speed, or rainfall) has
been reached or exceeded. When an alarm is triggered, the display emits an
audible beep and flashes data in the affected category. You can customize the
alarms by turning ON or OFF the alarms youʼd like activated or deactivated,
and by inputting your own
values to trigger the alarm.
Set up an Alarm
- Press and release the “ ” button until the reading for which you wish to set an alarm is shown on the display. “ ” will not be shown.
- Press and release the “ “ or “ “ buttons until “ ” appears.
- Press and release the “ set “ button. The current alarm value will flash on the display.
- Press and release the “ “ or “ “ buttons to adjust the alarmʼs value.
- Press and release the “ set ” button to save the alarm value.
- Press and release the “ ” button to cycle to the next reading.
Disable an Alarm
- Press and release the “ ” button until the reading for which you wish to disable an alarm is shown on the display. “ ” will be shown.
- Press and release the “ ” or ” ” buttons until “ ” appears.
- Press and release the “ ” button to cycle to the next reading.
- Repeat steps 1-3, as needed.
NOTE: To disable ALL alarms at once, press and HOLD the “ ” button for 10
seconds.
You will automatically exit the alarm SET MODE if no buttons are pressed for
10 seconds. Enter alarm SET MODE at any time by pressing the “ ” button.
Troubleshooting
Problem | Possible Solution |
---|
No outdoor sensor reception
no bars
| •Relocate the display and/or the 54n-1 sensor. The units must be within 330
ft (100 m) of each other.
•Make sure both units are placed at least 3 feet (.9 m) away from electronics
that may interfere with the wireless communication (such as TVs, microwaves,
computers, etc).
•Use standard alkaline batteries (or lithium batteries in the sensor when the
temperature is below -4°F/20°C). Do not use heavy-duty or rechargeable
batteries. NOTE: It may take a few minutes for the display and sensor to
synchronize after batteries are replaced.
•Synchronize the units:
1. Bring both the sensor and display indoors and remove the power
adapter/batteries from each.
2. Reinstall batteries in the outdoor sensor.
3. Reinstall power adapter/batteries in the display.
4. Let the units sit within a couple of feet of each other for a few minutes
to gain a strong connection.
Outdoor temperature is flashing or
showing dashes| Flashing of the outdoor temperature may be an indication of
wireless interference.
•Make sure the A-B-C switch in the battery compartments of both the display
and sensor are switched to the same letter. You may choose A, B, or C; but
both units must match to sync up. Sometimes changing to a different channel
can help.
Inaccurate forecast| •Weather Forecast icon predicts conditions for the next
12 to 24 hours, not current conditions.
•Has the Learning Mode icon disappeared from the display? Learning Mode must
complete before forecast and pressure will be accurate.
•Allow the unit to run continuously for 33 days. Battery removal or resetting
the display will restart Learning Mode. After 14 days, the forecast should be
fairly accurate, however, Learning Mode calibrates for a total of 33 days.
Inaccurate temperature or humidity| • Make sure both the display and 5-in-1
sensor are placed away from any heat sources or vents (see page 7).
• Make sure both units are positioned away from moisture sources (see page 7).
• Make sure 5-in-1 sensor is mounted at least 1.5 m (5 ft) off of the ground.
• Calibrate indoor and outdoor temperature and humidity (see page 7).
Display screen not working| • Check that the power adapter is plugged into the
display and an electrical outlet.
• Check that the batteries are installed correctly.
Batteries may need to be replaced.
• Reset the display by pressing and holding the RESET button for 10 seconds,
located in the battery compartment of the display. The date and time will need
to be entered after a reset.
If your AcuRite product does not operate properly after trying the
troubleshooting steps, visitwww.AcuRite.com or email
support@chaney-inst.com for assistance.
Care & Maintenance
Display Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt, and moisture. Clean ventilation ports regularly with a gentle puff of air.
Calibration
The indoor and outdoor temperature and humidity readings, and barometric
pressure can be calibrated on the display to improve accuracy. Calibration can
improve accuracy when sensor placement or environmental factors impact the
data accuracy.
- To access calibration mode, press AND HOLD the “ “, “set”, and “ ” buttons simultaneously for at least 5 seconds.
- To adjust the currently selected (flashing) item, press and release the “ ” or “ ” buttons to calibrate the data value higher or lower from the actual reading.
- To save your adjustments, press and release the “set” button to adjust the next The “ ” icon will remain illuminated next to calibrated values.
The preference set order is as follows:
OUTDOOR TEMPERATURE
OUTDOOR HUMIDITY
INDOOR TEMPERATURE
INDOOR HUMIDITY
BAROMETRIC PRESSURE (must be set to MANUAL mode to calibrate)*
*To change from AUTO to MANUAL pressure mode and vice versa, press AND HOLD the “set” button for 5-7 seconds. The display indicates the current pressure mode selected, “AUTO” or “MANUAL”. Press and HOLD the “set” button for 5-7 seconds to return to AUTO mode.
After 5-10 seconds of inactivity, the display will save the adjustments and exit calibration mode. NOTE: Calibrations will be erased if the display is reset or if batteries
Watch the video at www.acurite.com/5in1
Specifications
TEMPERATURE RANGE | Indoor: 32°F to 122°F; 0°C to 50°C |
---|---|
HUMIDITY RANGE | Indoor: 1 % to 99% |
WIND SPEED | 0 to 99 mph; 0 to 159 km/h |
WIND DIRECTION INDICATORS | 16 points |
RAINFALL | 0.01 inches (0.25 mm) and up |
WIRELESS RANGE | 330ft / 100m depending on home construction materials |
OPERATING FREQUENCY | 433 MHz |
POWER | 5V AC, 250mA adapter |
3 x AAA alkaline batteries (optional)
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may NOT cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE : This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur n a particular installation. If his equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increasetheseparationbetween the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment.
Such modifications could void the user’s authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference received, including interference that may cause undesired operation of the device.
Customer Support
AcuRite customer support is committed to providing you with best-in-class
service. For assistance , please have the model number of this product
available and contact us in any of the following ways:
support@chaney-inst.com
Visit us at www.AcuRite.com
► Installation Videos
► Instruction Manuals
► Replacement Parts
► Register your Product
► Support User Forum
► Submit Feedback & Ideas
Limited 1-Year Warranty
AcuRite is a wholly-owned subsidiary of Chaney Instrument Company. For
purchases of AcuRite products, AcuRite provides the benefits and services set
forth herein. For purchases of Chaney products, Chaneprovides the benefits and
services set forth herein.
We warrant that all products we manufacture under this warranty are of good
material and workmanship and, when properly installed and operated, will be
free of defects for a period of one year from the date of purchase.
Any product which, under normal use and service, is proven to breach the
warranty contained herein within ONE YEAR from the date of sale will, upon
examination by us, and at ur sole option, be repaired or replaced by us.
Transportation costs and charges for returned goods shall be paid for by the
purchaser. We hereby disclaim all responsibility for such transportation costs
and charges. This warranty will not be breached, and we will give no credit
for products that have received normal wear and tear not affecting the
functionality of the product, been damaged (including by acts of nature),
tampered, abused, improperly installed, or repaired or altered by others than
our authorized representatives. Remedy for breach of this warranty is limited
to repair or replacement of the defective item(s). If we determine that repair
or replacement is not feasible, we may, at our option, refund the amount of
the original purchase price.
THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY FOR THE PRODUCTS AND IS
EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ALL OTHER
WARRANTIES OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN ARE HEREBY
EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF
MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
We expressly disclaim all liability for special, consequential, or incidental
damages, whether arising in tort or by contract from any breach of this
warranty. Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion may not apply
to you. We further disclaim liability from personal injury relating to our
products to the extent permitted by law. By acceptance of any of our products,
the purchaser assumes all liability for the consequences arising from their
use or misuse. No person, firm or corporation is authorized to bind us to any
other obligation or liability in connection with the sale of our products.
Furthermore, no person, firm, or corporation is authorized to modify or waive
the terms of this warranty unless done in writing and signed by a duly
authorized agent of ours. In no case shall our liability for any claim
relating to our products, your purchase or your use thereof, exceed the
original purchase price paid for the product.
Applicability of Policy
This Return, Refund, and Warranty Policy apply only to purchases made in the
United States and Canada. For purchases made in a country other than the
United States or Canada, please consult the policies applicable to the country
in which you made your purchase. Additionally, this Policy applies only to the
original purchaser of our products. We cannot and do not offer any return,
refund, or warranty services if you buy products used or from resale sites
such as eBay or Craigslist.
Governing Law
This Return, Refund, and Warranty Policy is governed by the laws of the United
States and the State of Wisconsin. Any dispute relating to this Policy shall
be brought exclusively n the federal or state courts having jurisdiction in
Walworth County, Wisconsin; and purchaser consents to jurisdiction within the
State of Wisconsin.
It’s more than accurate, it’s
AcuRite offers an extensive assortment of precision instruments,
designed to provide you with information you can depend on to
Plan your day with confidence™.
www.AcuRite.com
© Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark
of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and
copyrights are the property of their respective owners. AcuRite uses patented
technology.
Visit www.AcuRite.com/patents for details.
Printed in China
06096 INST 111919
Documents / Resources
|
AcuRite 06096 Display for 5-in-1 Weather
Sensor
[pdf] Instruction Manual
06096, Display for 5-in-1 Weather Sensor
---|---
References
- Home
- AcuRite Weather Monitoring | #1 Weather Station Brand in North America
- 5-in-1 Weather Sensor Installation | AcuRite
- Icon Definitions and Terminology | AcuRite
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>