AcuRite 13024 Atomic Dual Alarm Clock Instruction Manual
- June 7, 2024
- Acurite
Table of Contents
Instruction Manual
Atomic Dual Alarm Clock
model 13024
Questions? Contact Customer Support at 877-221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.
Unpacking Instructions
Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel it off to remove it.
Package Contents
- Alarm clock
- Power adapter
- Instruction Manual
Features & Benefits
FRONT OF CLOCK
-
Snooze Button/Night Light
-
Alarm #1 ON/OFF Switch
-
Alarm #1 Setup Button
-
UP, DOWN & SET Buttons
for setup preferences. -
Alarm #2 Setup Button
-
Alarm #2 ON/OFF Switch** BACK OF CLOCK + Brightness Button**
-
Increases display brightness.
-
+/— Alarm Volume
Adjusts alarm volume. -
— Brightness Button
Decreases display brightness. -
USB Charging
for compatible smartphones. -
DC 5v Power Input BOTTOM OF CLOCK (inside the battery compartment)
-
RCC ON/OFF Switch
Controls synchronization with the atomic signal. -
ºF/ºC Temperature Units
-
Zone Button
Press to select a time zone.
Features & Benefits
-
Date
-
Atomic Clock
Sets itself to the correct time and automatically updates for Daylight Saving Time. -
Atomic Signal Strength
-
Alarm #1 Time
-
Alarm #1 Days Active
Indicates weekday, weekend, or everyday alarm. -
Alarm #2 Time
-
Alarm #2 Days Active
Indicates weekday, weekend, or everyday alarm. -
Alarm Volume
-
Indoor Temperature
Clock Setup
-
Plug-in Power Adapter
For the best performance, plug in the power adapter as the main power source for this product. -
Install or Replace Backup Batteries
1. Remove the battery compartment cover.
2. Insert 3 x AA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
3. Replace the battery cover. -
Plug-in Power Adapter
(on back of unit) -
Install or Replace Backup Batteries
3 AA alkaline batteries
IMPORTANT: Batteries are a backup power source to preserve records in the event of a power outage. Power adapter recommended as the primary power source to enjoy the full functionality of the product.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fre, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.
Atomic Clock (RCC)
AcuRite atomic clocks use a radio-controlled signal (RCC) to synchronize to
the correct time broadcast by the National Institute of Standards and
Technology (NIST) Radio Station WWVB, located near Fort Collins, Colorado.
WWVB broadcasts the current time and date with split-second accuracy.
The atomic clock and calendar will maintain the correct time and date, and
automatically update for daylight saving time to provide the most accurate
timekeeping standard possible.
When the RCC button, located under the battery compartment cover, is set to
ON, the clock will automatically search for the atomic clock signal.
To manually search for the atomic signal, make sure the RCC button is set to
ON, then press AND HOLD the “ “ button.
Please note: Signal reception is normally better at night and when the weather
is clear. The atomic signal generally takes a few hours to synchronize, so it
is important to manually set the time and date after powering on the clock.
Set the Time & Date
Press and hold the “ ” button, located on the front of the clock, to enter SET
MODE. Once in SET MODE the preference you are currently setting will blink on
the clock.
To adjust the currently selected (flashing) item, press and release the “ ” or
“ “ buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the “ ” button to adjust the next
preference. The preference set order is as follows:
TIME ZONE (PST MST CST EST AST HAST AKST)
AUTO DST ON/OFF
CLOCK HOUR
CLOCK MINUTE
CALENDAR MONTH
CALENDAR DATE
CALENDAR YEAR
You will automatically exit SET MODE if no buttons are pressed for 5 seconds.
Enter SET MODE at any time by pressing the “ ” button.
If you live in an area that observes daylight saving time, DST should be set to ON, even if it is not currently Daylight Saving Time.
Alarm Clock Placement
Place alarm clock in a dry area free of dirt and dust. To help ensure an accurate indoor temperature measurement, be sure to place the clock away from heat sources or vents.
Important Placement Guidelines
- To ensure accurate temperature measurement, place out of direct sunlight and away from any heat sources or vents.
- To maximize atomic signal reception, place the unit away from large metallic items, thick walls, metal surfaces, or other objects that may limit radio communication.
- To prevent wireless interference, place the unit at least 3 ft (.9 m) away from electronic devices (TV, computer, microwave, radio, etc.).
OPERATION
Using the Clock
Set the Alarm Time
Slide Alarm #1 and/or Alarm #2 switch ON (alarm time cannot be adjusted if the
alarm is OFF).
Press and release the or the button to enter ALARM SET MODE.
To adjust the currently selected (flashing) item, press and release the “ ” or
“ “ buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the or button to adjust the next
preference. The preference set order is as follows:
ALARM CLOCK HOUR
ALARM CLOCK MINUTE
ALARM EVERY DAY or WEEKDAY ONLY or WEEKEND ONLY
You will automatically exit ALARM SET MODE if no buttons are pressed for 5 seconds. Enter ALARM SET MODE at any time by pressing the or button.
Backlight
During power adapter use, press the Snooze button for momentary backlight at
100% brightness. During battery-powered use, press any button for a momentary
backlight.
The backlight MAY turn off at 2:00 AM and 3:00 AM to acquire the atomic clock
(RCC) signal.
USB Charging
Charge your mobile device by plugging your device’s USB power cord (not
included) into the USB charging port on the back of the clock.
USB charging is only available during power adapter use; USB charging is no
action when operating on battery power only.
Note: Follow the manufacturer’s instructions for your mobile device(s) to
determine compatibility with the USB charging feature on this product. Some
devices may not support USB charging or may require a higher power rating than
this product provides. Observe the charging status on your device. Ensure your
device is working properly before attempting to charge.
Troubleshooting
The clock is too dark, hard
to read or doesn’t
work| •The backlight may automatically turn off for 10 minutes at 2:00
am and 3:00 am to acquire the atomic clock signal.
• Verify power adapter is plugged in.
• Check that the batteries are installed correctly. Batteries may need to be
replaced.
• Increase brightness using +/– buttons, located on the back of the clock.
• The optimum viewing angle for this product is from slightly above it.
• Reset the unit by unplugging the power supply from the wall outlet and
remove any batteries that are installed. This will reset the alarm to the
original factory settings.
Time and date will need to be entered after a reset.
---|---
Inaccurate
temperature| • Make sure the clock is placed out of direct sunlight and
away from any heat sources or vents (see page 7).
Atomic signal or time
syncing problems| For additional troubleshooting, please visit:
http://www.nist.gov/pml/div688/grp40/radioclocks.cfm
If your AcuRite product does not operate properly after trying the troubleshooting steps, visitwww.AcuRite.com or call 877-221-1252 for assistance.
Care & Maintenance
Clock Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep
away from dust, dirt and moisture. Clean ventilation ports regularly with a
gentle puff of air.
Specifications
TEMPERATURE RANGE | 32ºF to 99ºF, 0ºC to 37ºC |
---|---|
POWER | 5v power adapter |
3 x AA alkaline batteries (for backup nly)
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
1- This device may NOT cause harmful interference, and
2- This device must accept any interference received, including interference
that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment. NOTE : This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equip- ment
generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference
to radio communications. However, There is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment.
Such modifications could void the user authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation of the device.
Customer Support
AcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any of the following ways:
24/7 support at www.AcuRite.com
► Installation Videos
► Register your Product
► Instruction Manuals
► Support User Forum
► Replacement Parts
► Submit Feedback & Ideas
Limited One Year Warranty
At AcuRite, we proudly uphold our commitment to quality technology. Chaney
Instrument Co. warrants that all products it manufactures to be of good
material and workmanship and to be free of defects when properly installed and
operated for a period of one year from the date of purchase.
We recommend that you visit us at www.AcuRite.com
for the fastest way to register your product. However, product registration
does not eliminate the need to retain your original proof of purchase in order
to obtain warranty benefits.
Chaney Instrument Co. warrants that all products it manufactures to be of good
material and workmanship and to be free of defects when properly installed and
operated for a period of one year from the date of purchase. Remedy for breach
of this warranty is limited to repair or replacement of the defective item(s).
Any product which, under normal use and service, is proven to breach the
warranty contained herein within ONE YEAR from the date of sale will, upon
examination by Chaney, and at its sole option, be repaired or replaced by
Chaney. Transportation costs and charges for returned goods shall be paid for
by the purchaser. Chaney hereby disclaims all responsibility for such
transportation costs and charges. This warranty will not be breached, and
Chaney will give no credit for products it manufactures which have received
normal wear and tear, been damaged (including by acts of nature), tampered,
abused, improperly installed, damaged in shipping, or repaired or altered by
others than authorized representatives of Chaney.
The above-described warranty is expressly in lieu of all other warranties,
express or implied, and all other warranties are hereby expressly disclaimed,
including without limitation the implied warranty of merchantability and the
implied warranty of fitness for a particular purpose. Chaney expressly
disclaims all liability for special, consequential or incidental damages,
whether arising in tort or by contract from any breach of this warranty. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you. Chaney
further disclaims all liability from personal injury relating to its products
to the extent permitted by law. By acceptance of any of Chaney’s products, the
purchaser assumes all liability for the consequences arising from their use or
misuse. No person, firm or corporation is authorized to assume for Chaney any
other liability in connection with the sale of its products. Furthermore, no
person, firm or corporation is authorized to modify or waive the terms of this
paragraph, and the preceding paragraph, unless done in writing and signed by a
duly authorized agent of Chaney. This warranty gives you specific legal
rights, and you may also have other rights which vary from state to state.
For in-warranty claims: Chaney Instrument Co.
965 Wells St., Lake Geneva, WI 53147
It’s more than accurate, it’s
AcuRite offers an extensive assortment of precision instruments, designed to
provide you with information you can depend on to plan your day with
confidence™.
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.
Printed in China
13024 INST 091713
Documents / Resources
|
AcuRite 13024 Atomic Dual Alarm
Clock
[pdf] Instruction Manual
13024, Atomic Dual Alarm Clock
---|---
References
- Home
- AcuRite Weather Monitoring | #1 Weather Station Brand in North America
- Help with WWVB Radio Controlled Clocks | NIST
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>