Quickstart
This is a secure Wall Controller for XXXQFrequencyName. To run this device please insert fresh *1 CR2450** batteries. To run this device please make sure the internal battery is fully charged.
- Turn on your Push Button.
- Activate adding mode on your Z-Wave controller.
- Activate adding mode of your Push Button by pressing and holding down both I and O of Group 2 for 3 seconds.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor, and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Product Description
The remote control is a Z-Wave device that can both control other Z-Wave devices and activate scenes in Gateways. Although it is controlling other devices, the device cannot act as a Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be added into the aZ-Wave network. The remote control has the following functions:
- Control of groups of other Z-Wave devices using ON, OFF, and Dim commands.
- Activation of scenes in Gateway mode.
Product Usage
Operation the device
– Push any button once or press and hold down any button to send scene
activation command to association Group 1 using Command Class Central Scene
Notification V3
- Push I-/O-button of Group 2 once, to send ON/OFF command to all associated
devices of Association Group 2.
– Press and hold down I-/O-button of Group 2, to send light intensity
increase/decrease command to all associated devices of Association Group 2.
– Push I-/O-button of Group 3 once, to send ON/OFF command to all associated
devices of Association Group 3.
– Press and hold down I-/O-button of Group 3, to send light intensity
increase/decrease command to all associated devices of Association Group 3.
– Push I-/O-button of Group 4 once, to send ON/OFF command to all associated
devices of Association Group 4.
– Press and hold down I-/O-button of Group 4, to send light intensity
increase/decrease command to all associated devices of Association Group 4.
– Push I-/O-button of Group 5 once, to send ON/OFF command to all associated
devices of Association Group 5.
– Press and hold down I-/O-button of Group 5, to send light intensity
increase/decrease command to all associated devices of Association Group 5
http://manuals- backend.z-wave.info/make.php?lang=en&sku=HEAE4512581&cert=ZC10-19086706&type=mini
How to check if the push button has already been added to a network
Press any button once. If the LED indicator does not turn on, the Push Button
does not belong to any network. If the LED indicator turns on, it means that
the Push Button has already been added to a network. You must then run the
removal process (see Removing from a Z-Wave network in this guide) before
adding
the device to your network.
Set association using the Push Button and the devices that are to be
controlled.
To control a Z-Wave device from the Push Button, the node ID of this device
needs to be assigned to one of the two association groups. This is a three-
step process:
a. Press and hold down both buttons I and O of Group 2 for 3 seconds until the
LED indicator turns on.
b. Push the I-button of any group once within 7s to associate the device to
this group. Push the O-button of any group once within 7s to remove the
association of the device from this group.
c. Operate the device to be controlled to send Node Information Frame (please
refer to the device manual) within 10 seconds, or set the device to exclusion
mode within 10 seconds, since it will send Node Information Frame in exclusion
mode, LED indications are as follows:
– LED blinks twice to indicate that the remote control failed to add the
associated device (the association group has already added the maximum
quantity of associated devices that it supports ).
– LED blinks 5 times to indicate that the remote control added the associated
device successfully.
– LED blinks 8 times to indicate that the remote control removed the
associated device successfully.
To remove all associated devices in an association group in the push button
directly
- Press and hold down both buttons I and O of Group 2 over 3 seconds, LED indicator turns on.
- Click the OFF button of any group on the Push Button 5 times continuously within 7 seconds to remove all associated devices of this group, LED indicator blinks 8 times to indicate that the associated devices are removed successfully.
Reset to factory default| Press and hold down both buttons I and 0 of Group 2
for a minimum of 10 seconds until the LED indicator turns on and then blinks 4
times quickly to indicate a successful factory reset.
---|---
Inclusion| Press and hold down both buttons I and 0 of Group 2 for 3 seconds.
The LED indicator turns on. the Push Button will be set to adding mode. and
stand by to be added to the network.
After 10s the LED indicator blinks 6 times quickly to indicate that the
addition has been successful.
Exclusion| Press and hold down both buttons I and 0 of Group 2 for 3 seconds.
LED indicator turns on. the Push Button MI be set to removing mode. and stand
by to be removed. After 7s the LED indicator blinks 4 times quickly to
indicate successful removal.
NIF| Press and hold down both I- and 0-buttons of Group 2 for 3 seconds.
Wakeup| Push any button once to activate the Push Button for 3s. and press and
hold down both the I- and 0-buttons of Group 2 for 1 second to activate the
Push Button for 7s.
Protection| XXXProtection
Firmware Update| XXXFirmwareUpdate
SetAssociation| XXXSetAssociation
Association Groups:
Group Number | MaximNodes | Description |
---|---|---|
1 | 5 | Lifeline 1. Send Command Class Device Reset Locally Notification V1 to |
associated devices of this group to report factory reset information when
factory reset the Push Button. 2. When Push Button battery power value
changes, send Command Class Battery Report V1 to associated devices of this
group to report power value information. 3. Short press or press and hold any
button to send scene activation command to the associated devices of this
group using Command Class Central Scene Notification V3
2| 5| Short press the I /O button of Group 2 to send the ON/OFF command to
associated devices of this group using Command Class Basic Set V2. Press and
hold down the I / O button of Group 2 to send light intensity
increase/decrease command to associated devices of this group using Command
Class Multilevel V4.
3| 5| Short press the I /O button of Group 3 to send the ON/OFF command to
associated devices of this group using Command Class Basic Set V2. Press and
hold down the I / O button of Group 3 to send light intensity
increase/decrease command to associated devices of this group using Command
Class Multilevel V4.
4| 5| Short press the I /O button of Group 4 to send the ON/OFF command to
associated devices of this group using Command Class Basic Set V2. Press and
hold down the I / O button of Group 4 to send light intensity
increase/decrease command to associated devices of this group using Command
Class Multilevel V4.
5| 5| Short press the I /O button of Group 5 to send the ON/OFF command to
associated devices of this group using Command Class Basic Set V2. Press and
hold down the I / O button of Group 5 to send light intensity
increase/decrease command to associated devices of this group using Command
Class Multilevel V4.
Configuration Parameters
Parameter 1: Factory Reset
Value=0x55AA, other values are invalid,factory reset the Remote Control
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
21930 | Factory Reset |
Technical Data
Dimensions | 71,2 x 71,2 x 13,6 mm |
---|---|
Weight | 66 gr |
Hardware Platform | ZM5101 |
IAN | 7071236014706 |
IP Class | IP 20 |
Voltage | 3V |
Battery Type | 1 * CR2450 |
Device Type | Wall Controller |
Network Operation | Portable Slave |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-19086706 |
Z-Wave Product Id | 0x019B.0x0300.0xa305 |
Z-Wave Scene Type | Central Scene |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
http://manuals- backend.z-wave.info/make.php?lang=en&sku=HEAE4512581&cert=ZC10-19086706&type=mini
References
- manuals-backend.z-wave.info/make.php?lang=en&sku=HEAE4512581&cert=ZC10-19086706&type=mini
- Smart Home Products - Aeotec
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>