SKYRC SK-500037 Infrared Thermometer Instruction Manual
- June 7, 2024
- SKYRC
Table of Contents
INSTRUCTION MANUAL
Infrared Thermometer
SK-500037
INTRODUCTION
The SkyRC 380P Infrared Thermometer is a must-have for RC hobbyists to track
the temperatures of the RC vehicle’s motor, engines, motors, ESC, battery
packs, battery chargers, etc.
The ultra-compact design lets you slip it in your pocket and have it handy for
quick, precise temperature readings at any time.
As an added value upgrades to its predecessor, the VA invert display uses an
advanced multi-domain vertical alignment technology that gives you super-high
static contrast ratios for impressive stunning visioning.
Wherever you are indoor or outdoor, you will get clear data reading from any
angle.
This thermometer is intended for RC hobbyists only with its customized
structure and sensitivity.
It is not recommended to be used as a medical thermometer (also called
clinical thermometer) to measure human or animal bodies.
FEATURES
- High accuracy and high-speed infrared sensor
- D:S ratio: 6:1
- Wide range of temperature from -40°C(-40°F) to 380°C(716°F)
- NIST traceable calibration
- Easily selectable between °F and °C
- Low-battery indication
- Auto-power off after inactivity of one minute
- Compact design
- Four modes for temperature records: Quick Mode / Scan Mode / Max. Value / Min. Value
- Adjustable emissivity coefficient
- Low power consumption and powered by 2 x AAA batteries (Battery Excluded).
- Data at a glimpse
- VA display with backlight: impressive contrast and wider vision from every angle
- Beep signals for every operation and can be silenced
MEASURING TEMPERATURES
There are four methods to measure temperatures. Point the aluminum cup located on the top end of the gauge directly at the object to measure, and do one of the following:
-
Quick Mode
Press the MEASURE button once for an instantaneous temperature reading to show on-screen. -
Scan Mode
Move the aluminum cup as close as possible to the target.
Press and hold the MEASURE button to read temperatures continually. The temperature on-screen will be updated continuously. Releasing the MEASURE button will cause the last reading to display onscreen. This thermometer can temporarily store maximum or minimum temperatures. Turn the unit on by pressing the MEASURE button. Then, press the MODE button once for the maximum or twice for the minimum. The respective MAX or MIN icon will display on on- screen. -
Maximum/Minimum Temperature Modes
To check the MAX or MIN temperature, click the MODE button to choose the right mode, point the cup to the object, press and hold the MEASURE button to observe the respective value.
MEASUREMENT TIPS
Distance-to-spot ratio: 6:1
Every infrared thermometer has a “distance-to-spot” (D:S) ratio that tells you
the diameter of the area being measured compared to the distance from the
target.
The 380P thermometer has a distance-to-spot ratio of 6:1.
That means it measures an approximately one-inch diameter spot when it’s 6
inches from the target (about 2.5 cm at 30 cm). If you try to use that
thermometer to measure a two-inch (5-cm) area from even just a few feet (1 m)
away, you will not get an accurate result because the meter will also measure
the temperature outside the area you are targeting.
The Distance-to-spot ratio is crucial to measuring! So be sure to measure at
this D:S ratio.
Measuring Metallic Target
In general, infrared thermometers can easily measure non-metallic surfaces
because they emit most of the potential heat. On the other hand, metallic
surfaces are poor emitters requiring special treatment before measuring.
Fortunately, that special treatment is simple and can be easily accomplished
by marking the metallic surface you wish to measure with a non-metallic
substance such as a solid paint marker.
When operating in MAX or SCAN modes, mark the appropriate target area and
measure at the D:S ratio of 6:1.
Measuring Transparent Materials
Although transparent materials pass visible light, many visibly transparent
materials are opaque in the infrared and can be directly measured by the 380P
thermometer.
To test infrared transparency, touch the 380P to the target’s surface and pass
a heat source such as your hand or a penlight through the sensor’s field of
view on the other side of the material.
If the 380P responds to the heat source, the material is transparent in the
infrared and requires marking the surface for proper measurement.
Mark the surface with an opaque non-metallic coating, such as paint or grease.
Alternatively, put a shiny metallic object, such as aluminum foil, behind the
transparent material.
Measuring Wet or Icy Surfaces
Wet or icy surfaces may interfere with the 380P’s readings. Water and other
liquids are good targets, but evaporation lowers their surface temperatures.
Frost forms on a surface at the freezing point of water. Frozen foods or
similar targets will form frost in some circumstances.
In the frost forms, the thermometer will measure the frost instead of the
object.
Melting ice will read slightly higher than 32 °F (0°C) because the meter
measures the air condensing on the ice, a reaction that generates a small
amount of heat. As long as the ice is not melting, the 380P will accurately
read its temperature.
To get an accurate measurement, remove any ice or moisture before aiming.
GENERAL OPERATION
-
Battery Installation
This thermometer is powered by 2 AAA batteries. With thumbs on the battery compartment cover, push down and slide.
-
Battery Replacement
It is necessary to replace the battery when it indicates low. Low power affects the accuracy of the measurement.
Open the battery compartment and replace them with two new AAA batteries.
-
Measure at this D:S ratio of 6:1
-
Beep Sound On or Off
There is a beep signaling each operation.
Press and hold the MODE button for 5 seconds to turn on or off as expected. -
Switch Measurement Unit
Turn on the device by pressing the MEASURE button. Pressing the UNIT button to switch the unit
between Celsius and Fahrenheit. -
Change the Emissivity Coefficient Value
The emissivity of a material (usually written ε) is the relative ability of its surface to emit energy by radiation.
The ratio of energy radiated by a particular material differs from the energy released by a black body at the same temperature.
Different types of materials have different emissivity values.
Emissivity Coefficients of some common Materials for RC products
SURFACE MATERIAL | EMISSIVITY COEFFICIENT |
---|---|
Aluminum Anodized | 0.77 |
Plastics | 0.91 |
Rubber, hard glossy plate | 0.94 |
Carbon pressed filled surface | 0.98 |
In general, if you are not comfortable changing emissivity value, it is best
NOT to change it. The factory default emissivity value is 0.95, which provides
accurate temperature measurements for most materials.
To change the emissivity setting, hold the MODE and UNIT buttons
simultaneously.
The emissivity value on the screen will be blinking:
To increase the value, press the MODE button;
To decrease the value, press the UNIT button.
SPECIFICATION
- Operation Voltage: AAA battery X 2
- Operation Current: ≤40ma@2.0V
- Operation Temperature: 0-40°C
- Current Drain: ≤25ua@3V
- Precision: -40°C-0°C ±1°C 0°C-60°C ±0.5°C 60°C-120°C ±1°C 120°C-180°C ±2°C 180°C-240°C ±3°C 240°C-360°C ±4°C
- Adjustable Range for Infrared Emission Frequency: 0.01-1
- Dimension: 121x40x39.6mm
- Weight: 75g
WARRANTY AND SERVICE
We guarantee this product to be free of manufacturing and assembly defects for
a period of one year from the time of purchase. The warranty only applies to
material or operational defects, which are present at the time of purchase.
During that period, we will repair or replace free of service charge for
products deemed defective due to those causes.
This warranty is not valid for any damage or subsequent damage arising as a
result of misuse, modification or as a result of failure to observe the
procedures outlined in this manual.
Note:
- The warranty service is valid in China only.
- If you need warranty service overseas, please contact your dealer in the first instance, who is responsible for processing guarantee claims overseas. Due to high shipping costs, complicated custom clearance procedures to send back to China. Please understand SkyRC can’t provide warranty service to the overseas end user directly.
- If you have any questions which are not mentioned in the manual, please feel free to send an email to info@skyrc.com
Manufactured by
SKYRC TECHNOLOGYFCO., LTD.
www.skyrc.com
7504-1441-02
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>