HEATIT Z-TEMP2 Thermostat For Water Heating
INTRODUCTION
Heatit Z-Temp2 is a battery-operated thermostat designed for use with water
based heating systems. Used in combination with the Heatit Z-Water regulator
you can control your heating system with a Z-Wave primary controller/gateway
with the use of Heatit Z-Water in combination with one or several Heatit
Z-Temp2.
INSTALLATION
Fix the unit to the wall by double-sided tape, screws or installed on top of a
Euro wallbox. Make sure the mounting surface is clean and
dry.
ADD/REMOVE
- During this process it is recommended to have the thermostat as close to the primary controller/gateway as possible.
- Please refer to your primary controller/gateway manual on how to enter add/remove mode.
- The device can only be added or removed from the network if the primary controller is in add/remove mode.
- When the primary controller/gateway is set to add/remove modus press the link button on the thermostat 3 times in a rapid sequence.
- When the device successfully has entered learning mode, the thermostat will show “circling LEDs” in the display.
This is done by using association groups from the thermostat’s root device (EP0) with Group 3 (GR3) towards your actuator device (using Multichannel or Singlechannel, based on the controlled device type. To set associations in your primary controller/gateway, please refer to your gateway’s user manual.
ADD
If the thermostat is successfully added to a Z-Wave network, the thermostat
will display “INC”.
REMOVE
If the thermostat is REMOVED from the Z-Wave network, the device will display
“ECL”.
ERROR
The thermostat is already added in a Z-Wave network or the inclusion process
is timed out the thermostat displays “Err”. Follow the removing process before
adding it into your network. Otherwise, the adding of this device will fail.
When the device is removed from the network, the device will revert to factory
settings. PS! The learning mode will timeout after 90 seconds if the
thermostat does not register the gateway.
SETTING ASSOCIATIONS
After the device is added to your Z-Wave gateway you will need to link the
thermostat to the device that is going to control the heating.
TECHNICAL DATA
- Protocol Z-Wave
- Chip Z-Wave 700 chip
- Rated voltage 3 x AA batteries (1,5V)
- Ambient temperature 0°C to 60°C
- Humidity Max 85% RH
- Range RF Min. 40 meters
- Hysteresis 0,3°C to 3,0°C (default 0,5°C)
- IP Code IP 21
- Approvals Z-Wave Plus V2
CE, RED 2014/53/EU, ETSI EN 301 489-1 V2.2.3 (2019-11), ETSI EN 301 489-3 V2.1.1 (2019-03), ETSI EN 300 220-1 V3.1.1 (2017-02), ETSI EN 300 220-2 V3.2.1 (2018-06), EN 62479:2010, EN 62368-1:2014+A11:2017, RoHS 2011/65/EU
Heatit Controls AB can not be held liable for typographical errors, other errors or omittances in our information. Product specifications may change without further notice. All electrical installations must be carried out by a licensed electrician. The product must be installed in accordance with national building codes and our installers manual.
Heatit Controls AB l Läkarvägen 4, 454 31 BRASTAD, SWEDEN
Phone: +47 61 18 77 77 l post@heatit.com –
www.heatit.com