Introduction:
ENFORCER IR Proximity Sensors are compact and can be programmed to unlock an electronic door lock when an object (such as a hand) is passed in front of the sensor or trigger an alarm when an object (such as a valuable possession) is removed from the sensing area. This flexibility makes the sensors ideal for both anti-theft and access control applications.
- Access control: Mount the sensor to a wall or plate in a protected area. A user can wave a hand in front of the sensor to unlock an electric lock for no-touch, protected egress.
- Anti-theft: Place the sensor under or behind a painting or other valuable object. If the object is removed, the sensor will trigger an alarm to alert the owner
Parts List:
- 1x IR proximity sensor
- 1x Wiring harness
- 1x Hex nut
- 1x O-ring
- 1x Manual
Installation:
NOTES:
- Only the front is IP65 rated. For weatherproof installation, the O ring must be used as shown and the area behind the mounting surface must be protected from moisture incursion.
- To ensure proper operation, make sure no objects sit or come within 113 /4″ (30cm) (60° to the left and right) of the front of the IR proximity sensor to avoid interference.
Overview:
-
CS-PD419-PQ
-
CS-PD115-PAQ
-
CS-PD115-PAQ
-
CS-PD422-PQ
-
CS-PD438-PQ
-
CS-PD419-PQ
CS-PD422-PQ
CS-PD438-PQ
IR Range and Trigger Time Settings:
- CS-PD115-PAQ
Toggle mode:
Set the trigger time to maximum.
Sample Wiring:
Wiring to an Alarm for Anti-Theft
*Sensor covered (relay active) in normal state
Wiring to an N.O. Door Strike for Wave-to-Open Egress
†Suggest connecting a metal oxide varistor (MOV) and diode (both not included)
as close as possible and in parallel with the controlled output
device. This absorbs possible electromagnetic interference to prevent damaging
the IR proximity sensor.
ENFORCER Infrared Proximity Sensors
Sample Applications:
-
Anti-Theft
-
Place the sensor under or behind a valuable object. If the object is removed from the sensor, the sensor will trigger an alarm to alert the owner that the item is out of place.
-
Access Control
-
Mount the sensor to a wall or plate in a protected area. A user can wave his or her hand in front of the sensor to unlock an electronic door lock, allowing germ-free, protected egress
Available Models:
-
CS-PD115-PAQ
-
CS-PD419-PQ
-
CS-PD422-PQ
-
CS-PD438-PQ
Model | Size | Material |
---|---|---|
CS-PD115-PAQ | ø3/4″ (ø19mm) | Polycarbonate |
CS-PD419-PQ | ø3/4″ (ø19mm) | Stainless steel and polycarbonate |
CS-PD422-PQ | ø7/8″ (ø22mm) | Stainless steel and polycarbonate |
CS-PD438-PQ | ø11/2″ (ø38mm) | Stainless steel and polycarbonate |
- No-touch operation reduces the risk of spread of germs, viruses, etc., through cross-contamination
- Triggers a warning or locking device when the sensor is triggered
- Form C relay output (1A@30VDC)
- Adjustable output time (0.5~30 s) or toggle
- Adjustable sensor range up to 6″ (15cm)
- Selectable LED colors (turns from red to green or green to red on activation)
- 12~24 VDC Operation
- Variety of sizes allow for a wide range of applications
- Filters out interference from other infrared sources
- Weatherproof front panel (IP65)*
Specifications:
Model| CS-PD438-PQ| CS-PD422-PQ| CS-PD419-PQ| CS-
PD115-PAQ
---|---|---|---|---
Diameter| ø11/2″ (ø38mm)| ø7/8″ (ø22mm)| ø3/4″ (ø19mm)
Case material| Stainless steel and polycarbonate| Polycarbonate
Operating voltage| 12~24 VDC
Power consumption| 12VDC| 35mA@12VDC| 30mA@12VDC
24VDC| 45mA@24VDC| 35mA@24VDC| 30mA@12VDC
Relay type| Form C dry contact, NO/NC/COM, 1A@24VDC, 0.5A@12VAC
Connectors| Wire terminals
Response time| 10ms
Output time| 0.5~30 s or Toggle
Sensing range| 19/16″~6″ (4~15 cm)
LED Status indicator| Selectable red/green or green/red
Operating life| Relay| 1,000,000 cycles
Sensor| 100,000 Hours
IP Rating| IP65 (front panel only)
Operating temperature| 4°~131° F (-20°~55° C)
Troubleshooting:
The indicator light is continuously green| Check that there are no objects in
front of the sensor
---|---
Adjust the sensor’s range to be shorter (see IR Range and Trigger Time
Settings )
Check that the power supply’s voltage is 12~24 VDC
Adjust the trigger time setting – a long delay or enabling toggle mode could
affect the sensor’s operation
The indicator light will not turn green| Adjust the sensor’s range to be
longer (see IR Range and Trigger Time Settings )
Check that the power supply’s voltage is 12~24 VDC
IMPORTANT: Users and installers of this product are responsible for ensuring that the installation and configuration of this product complies with all national, state, and local laws and codes related to locking and egress devices. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.
WARRANTY:
This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO- ARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2020 SECO-LARM U.S.A., Inc. All rights reserved.
SECO-LARM® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Website: www.seco-larm.com
Phone: 949-261-2999 |
800-662-0800
Email: sales@seco-larm.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>