CHAMBERLAIN RTX8P 8 Channel Transmitter Instructions
- June 6, 2024
- CHAMBERLAIN
Table of Contents
CHAMBERLAIN RTX8P 8 Channel Transmitter
IMPORTANT SAFETY RULES – SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS FOR THE USER
Caution! Non-compliance can result in serious injury. Do not allow children to
play with the controls.
- Any work on the electrical installation including servicing may only be performed by a qualified electrician.
- Check shutter or sun-blind system regularly for signs of wear and damage. Damaged systems should not be used under any circumstances until such time as they have been repaired.
- Observe shutter or sun-blind system carefully whilst in operation.
- Only those spare parts, tools and other equipment as have been approved by Chamberlain may be used.
- Fit control facilities within sight of the product to be controlled at a height of at least 1.5 m.
CORRECT USE
The remote controls in this product are only suitable for use in conjunction
with shutter drives made by Chamberlain (ER-Series). Should your existing
remote control have a different design, it is not compatible with these
devices!
To ensure that these remote controls function properly, a radio-controlled
shutter drive (ER-Series) made by Chamberlain or a
universal receiver (Models: RRX1) is required.
Any other form of usage is deemed to be incorrect. Neither the manufacturer
nor the supplier assumes any liability for personal injury, damage to property
or consequential injury or damage occurring as a result of the use of the
control units and / or drives for purposes other than those mentioned above or
due to changes made to the equipment affecting the safety of the given system.
The details stipulated in the Operating Instructions in respect of the
operation and repair of the system require strict observance. Neither the
manufacturer nor the supplier assumes any liability for personal injury,
damage to property or consequential injury or damage occurring as a result of
non-compliant actions.
PROGRAMMING REMOTE CONTROL
The remote control is compatible with:
Chamberlain tubular motor: RPD10ER, RPD15ER, RPD25ER, RPD40ER
Chamberlain receiver: RRX1
Press the learn button on the master hand-held remote control (1) or the
already programmed remote control 8 x (motor bleep) and then press the learn
key of the new remote control (2). The motor confirms this with a short jerk
in each direction. New remote control has been successfully programmed. In the
case of individual operation, the channel can be changed using the „A“ – „C“
key.
For programming a master remote control / on receiver model RRX1 see
corresponding instructions!
CENTRAL CONTROL
-
Press the „B“ button to select between single and central control.
-
Press and hold the „B“ button for 2 seconds to set the remote control to central learn mode. The channel will start blinking.
-
Use the „A“ and „C“ buttons to select the desired channels and press the „B“ button to briefly confirm or
cancel each channel. The confirmed channel is displayed in a frame. -
Press the OPEN, STOP, CLOSE buttons simultaneously to confirm the desired channels for central control. The programming of one of the central controls is finished.
CHANGE / DELETE CENTRAL CONTROL
- Press the „B“ button to select between single and central control.
- Press and hold the „B“ button for 2 seconds to set the remote control to central learning mode. The channel will start flashing.
- Select the desired channels with the „A“ and „C“ buttons and confirm or cancel each channel briefly with the „B“ button. The deleted channels are displayed without a frame. The added channels are displayed in a frame.
- Press the OPEN, STOP, CLOSE buttons simultaneously to confirm the desired changes for the central control.
The change / deletion of the central control is finished.
TECHNICAL DATA
Battery type / QTY|
CR2430 / 1
---|---
Power supply|
3V DC
max. remote control power|
≤ 10mW
Frequency|
433,92 MHz
System|
Rolling code
Degree of protection|
IP30
Temperature|
-10°C – +50°C
DISPOSAL
The packaging must be disposed of in the local recyclable containers.
According to the European Directive 2002/96/EC on waste electrical equipment,
this device must be properly disposed of, after usage in order to ensure a
recycling of the materials used. Old accumulators and batteries may not be
disposed of in the household waste, since they contain pollutants and must be
properly disposed of in municipal collection points or in the containers of
the dealer provided. Country-specific regulations must be observed.
EU DECLARATION OF CONFORMITY
Hereby, Chamberlain GmbH declares that the radio equipment type RTX8P is in
compliance with Directive 2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet address:
https://chamberlain.de/Chamberlain/media/Chamberlain/CE/114ADoC-
RTX-D-2020.pdf
Chamberlain GmbH
Saar-Lor-Lux-Str. 19
66115 Saarbrücken, Germany
Tel. 0049 681 870 80 100
WEEE-Reg.Nr. DE66256568
www.chamberlain.eu
info@chamberlain.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>