Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT Instruction Manual

June 5, 2024
CHAMBERLAIN

Chamberlain logo RECEIVER LOGIC BOARD REPLACEMENT
Models 050DCTBFMC and 050DCTBFLKMC
Instruction Manual

NOTE: model 050DCTBFMC replaces WF/TB/TBMC and model 050DCTBLKMC replaces WFLK/TBLK/TBLKMC.

Installation

1. Before you begin
Your garage door opener has an internal gateway located on the receiver logic board. After installing the new receiver logic board, use the myQ® serial number found on the provided label to add your garage door opener to your myQ® account. The products illustrated in the instructions are for reference. Your product may look different. The logic board firmware has been updated. The update provides a new Obstruction Notification that signals when the opener senses resistance, such as an obstruction or other binding in the door and rail system. The door will stop or reverse to the open limit and the opener will beep and the lights flash 5 times.

Warning-icon.pngWARNING
To prevent possible SERIOUS INJURY or DEATH:

  • Disconnect ALL electric and battery power BEFORE performing ANY service or maintenance. 

Warning-icon.pngCAUTION
To prevent damage to the receiver/logic board, DO NOT touch the printed circuit board of the replacement receiver/logic board during installation.
ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment. 

WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer or birth defects, or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
1| 1.1 Remove the light lens by pulling the top side of the light lens and swinging the light lens down. Squeeze the light lens clips to remove the lens from the end panel.
---|---
Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
2| 1.2 To maintain your warranty, place the provided label over the existing label on the end panel of the garage door opener.
Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
3| 1.3 Disconnect electrical and battery power (if applicable) to the garage door opener.

2. Remove the receiver logic board

2.1 Disconnect the wires from the quick-connect terminals
(A). Disconnect any wires from the lock terminals.
Remove the receiver logic board end panel from the garage door opener.| 2.2 Unplug the wire harnesses from the receiver logic
board. You may need needle-nosed pliers, to remove the harnesses.| 2.3 Remove the receiver logic board from the
end panel by removing the 2 screws and releasing the 2 clips.
---|---|---
Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
4To insert or remove the wires from the terminal, push in the tab with a screwdriver tip.| Chamberlain 050DCTBFMC
CLOGIC BOARD REPLACEMENT - FIG 5|

3. Install a new receiver logic board
For garage door openers without a battery backup system:
remove the button pad from the logic board and replace it with the alternate button pad.

Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
7

3.1 Connect the wire harnesses to the
new receiver logic board. When
reconnecting the wire harness, be sure
the tabs on the wire harness are facing
the end panel, not the logic board.| 3.2 Insert the antenna wires through
the holes in the end panel. Snap the
receiver logic board into place on the
end panel and fasten it with screws.| 3.3 Reinsert the wires.
Door control wires:
• white wire into the white terminal.
• white/red wire into the red terminal.
Safety sensor wires:
• white wires into the white terminal.
• white/black wires into the grey terminal.
Reconnect any lock terminal wires.
---|---|---
Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
8| Chamberlain 050DCTBFMC CLOGIC BOARD
REPLACEMENT - FIG 9| Chamberlain
050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG 11
NOTE: If your logic board
has a wire clip, use the
wire clip to hold wires to
the logic board.| NOTE: Some models will require
the short antenna wire to be placed in the traps of the end panel. | 3.4 Install the light lens by aligning with the hinges and snapping it into place.
Reconnect power.
NOTE: When installing the light lens, ensure the
antenna wires are hanging straight down.

NOTE: A test of the safety reverse system is necessary for safe operation.

Programming

1. Program a remote using the learn button

1.1 Press and release the Learn button on the garage door opener. The Learn indicator light will glow steadily for 30 seconds.| 1.2 Within 30 seconds, press and hold the button on the remote control.| 1.3 Release the button when the garage door opener light blinks. It has learned the code. If light bulbs are not installed, two clicks will be heard.
---|---|---
Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
12| Chamberlain 050DCTBFMC CLOGIC BOARD
REPLACEMENT - FIG 13| Chamberlain
050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG 14

To program the Wi-Fi garage door opener to your network refer to your owner’s manual.

Adjustment

1. Program the travel
Warning-icon.pngWARNING
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.

  • Incorrect adjustment of garage door travel limits will interfere with the proper operation of the safety reversal system.
  • After ANY adjustments are made, the safety reversal system MUST be tested. The door MUST reverse on contact with a 1-1/2″ (3.8 cm) high object (or 2×4 laid flat) on the floor

While programming the travel, the UP and DOWN buttons can be used to move the door as needed. The Safety Reversing Sensors will be disconnected during the Program the Travel process. During the Automatic Force Setup, the door will automatically open and close.

Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
15| 1.1 Press and hold the Adjustment Button until the UP Button begins to flash and/ or a beep is heard.
The Safety Reversing Sensors will be disconnected during the Program the Travel process.
---|---
Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
16| 1.2 Press and hold the UP Button until the door is in the desired UP position.
Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
17| 1.3 Once the door is in the desired UP position press and release the Adjustment Button. The garage door
opener lights will flash twice and the DOWN Button will begin to flash.
Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
18| 1.4 Press and hold the DOWN button until the door is in the desired DOWN position.
Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
19| 1.5 Once the door is in the desired DOWN position press and release the Adjustment Button. The garage door opener lights will flash twice. Program the Travel is now complete. If the garage door opener lights flash 5 times, then programming has timed out and the Travel Limits have not been set. Please restart the Program and the Travel process.
1.6 Add the Step Saver sticker under the yellow program button.

2. Automatic Force Set Up
Once both the up and down positions have been manually set, the Safety Reversing Sensors will reconnect and become operational. Then, the opener will enter a force-sensing operation by automatically moving the door open and close. The garage door opener will sound an audible and visual alert before automatically opening and closing the door. The garage door opener will beep three times, confirming that the Automatic Force Setup was completed successfully. Adjustment is complete.
If you hear one long beep after the door attempts to move, then the Automatic Force Set-Up has not been completed successfully. Please start over at step 1 of Program the Travel.

Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
20

3. Test the Safety Reversal System

Warning-icon.pngWARNING

Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.

  • The safety reversal system MUST be tested every month.
  • After ANY adjustments are made, the safety reversal system MUST be tested.

The door MUST reverse on contact with a 1-1/2″ high (3.8 cm) object (or 2×4 laid flat) on the floor.

Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
21| 3.1 With the door fully open, place a 1-1/2 inch (3.8 cm) board (or a 2×4 laid flat) on the floor, centered under the garage door.
---|---
Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
22| 3.2 Press the remote control push button to close the door. The door MUST reverse when it makes contact with the board.

If the door stops but does not reverse:

  1. Repeat Program the Travel (see Adjustment Step 1);
  2. Repeat the Safety Reversal test.

If the test continues to fail, call a trained door systems technician.

4. Test the Protector System®

WARNING
Without a properly installed safety reversing sensor, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.

Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
23| 4.1 Open the door. Place an obstruction in the path of the door.
---|---
Chamberlain 050DCTBFMC CLOGIC BOARD REPLACEMENT - FIG
24| 4.2 Press the remote control push button to close the door. The door will not move more than an inch (2.5 cm).

The garage door opener will not close from a remote control if the LED in either safety reversing sensor is off (alerting you to the fact that the sensor is misaligned or obstructed).
If the garage door opener closes the door when the safety reversing sensor is obstructed (and the sensors are no more than 6 inches [15 cm] above the floor), call for a trained door systems technician.

© 2022, The Chamberlain Group LLC.
All Rights Reserved
Todos los derechos reservados
114-5824-000

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

CHAMBERLAIN User Manuals

Related Manuals