Milesight EM300 Series Temperature and Humidity Sensor User Guide
- June 6, 2024
- Milesight
Table of Contents
Milesight EM300 Series Temperature and Humidity Sensor
Applicability
This guide is applicable to EM300 series sensors shown as follows, except where otherwise indicated.
Model
|
Description
---|---
EM300-TH
| Temperature and Humidity Sensor
EM300-MCS
| Magnet Switch Sensor
EM300-SLD
| Spot Leak Detection Sensor
EM300-ZLD
| Zone Leak Detection Sensor
Safety Precautions
Milesight will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide.
- The device must not be remodeled in any way.
- The device is not intended to be used as a reference sensor, and Milesight will not should responsibility for any damage which may result from inaccurate readings.
- Do not place the device close to objects with naked flames.
- Do not place the device where the temperature is below/above the operating range.
- Make sure electronic components do not drop out of the enclosure while opening.
- When installing the battery, please install it accurately, and do not install the reverse or wrong model.
- Make sure both batteries are newest when install, or battery life will be reduced.
- The device must never be subjected to shocks or impacts.
Declaration of Conformity
EM300 series is in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS.
© 2011-2021 Xiamen Milesight IoT Co., Ltd.
All rights reserved.
All information in this guide is protected by copyright law. Whereby, no
organization or individual shall copy or reproduce the whole or part of this
user guide by any means without written authorization from Xiamen Milesight
IoT Co., Ltd.
For assistance, please contact Milesight technical support:
Email: iot.support@milesight.com
Tel: 86-592-5085280
Fax: 86-592-5023065
Revision History
Date
| Doc Version|
Description
---|---|---
October 14, 2020
|
V 1.0
| Initial version
October 21, 2020
|
V 1.1
| Model name change and pictures replace
November 19, 2020
|
V 2.0
| Layout replace
Product Introduction
Overview
EM300 series is a sensor mainly used for outdoor environment through wireless
LoRa network. EM300 device is battery powered and designed for multiple
mounting ways. It is equipped with NFC (Near Field Communication) and can
easily be configured by a smartphone or a PC software.
Sensor data are transmitted in real-time using standard LoRaWAN® protocol.
LoRaWAN® enables encrypted radio transmissions over long distance while
consuming very little power. The user can obtain sensor data and view the
trend of data change through Milesight IoT Cloud or through the user’s own
Network Server.
Features
- Up to 11km communication range
- Easy configuration via NFC
- Standard LoRaWAN® support
- Milesight IoT Cloud compliant
- Low power consumption with 4000mAh replaceable battery
Hardware Introduction
Packing List
-
1 × EM300 Sensor
-
Wall Mounting Kits
-
1 × Warranty Card
-
1 × Quick Guide
-
Double Sided Tape (for SLD or MCS sensor)
-
Mounting Screws (for SLD or MCS sensor)
-
1 × NFC Reader (Optional)
If any of the above items is missing or damaged, please contact your sales representative.
Product Overview
-
Front View:
① NFC Area
-
Bottom View:
② Vent
③ Waterproof Connectors
(For water leakage and magnet switch sensor)
-
Internal View:
④ LED
⑤ Power Button
⑥ USB Type-C
⑦ Expandable Battery Slot
⑧ Battery
Dimensions (mm)
Power Button
Note: The LED indicator and power button are inside the device. EM300 can also be turned on/off and reset via Mobile APP or Toolbox.
Function
| Action|
LED Indication
---|---|---
Turn On
| Press and hold the button for more than 3 seconds.|
Off → Static Green
Turn Off
| Press and hold the button for more than 3 seconds.|
Static Green -> Off
Reset
| Press and hold the button for more than 10 seconds.
Note: EM300 will automatically power on after reset.|
Blink 3 times.
Check On/Off Status
| Quickly press the power button.|
Light On: Device is on.
Light Off: Device is off.
Basic Configuration
EM300 sensor can be monitored and configured via one of the following methods:
- Mobile APP (NFC);
- Windows software (NFC or Type-C port).
In order to protect the security of sensor, password validation is required when configuring via unused phone . Default password is 123456.
Configuration via Smartphone APP
Preparation:
- Smartphone (NFC supported)
- Toolbox APP: download and install from Google Play or Apple Store.
Read/Write Configuration via NFC
-
Enable NFC on the smartphone and open “Toolbox” APP.
-
Attach the smartphone with NFC area to the device to read basic information.
Note: Ensure your smartphone NFC area and it is recommended to take off phone case before using NFC.
-
Change the on/off status or parameters, then attach the smartphone with NFC area to the device until the APP shows a successful prompt.
-
Go to “Device > Status” to tap “Read” and attach the smartphone with NFC area to the device to read real-time data of sensor.
Template Configuration
Template settings only work for easy and quick device configuration in bulk.
Note: Template function is allowed only for sensors with the same model
and LoRa frequency band.
-
Go to “Template” page on the APP and save current settings as a template.
-
Attach the smartphone with NFC area to another device.
-
Select the template file from Toolbox APP and tap “Write”, keep the two devices close until the APP shows a successful prompt.
-
Slide the template item to the left to edit or delete the template.
Configuration via PC
Preparation:
- Dedicated NFC Reader or Type-C USB cable
- PC (Windows 10 is recommended)
- Toolbox: https://www.milesight-iot.com/software-download/
Log in the Toolbox
Make sure “Toolbox” is downloaded on your computer. Select one of the
following methods to log in Toolbox.
Type-C Connection
-
Open the case of EM300 and connect the EM300 to computer via type-C port.
-
Select type as “General” and click password to log in Toolbox. (Default password: 123456)
NFC Connection
-
Connect the NFC reader to computer, then attach the EM300 to NFC area of the reader.
-
Select type as “NFC” and serial port as NFC reader port on Toolbox.
Basic Configuration
-
Click “Read” to read current data of the sensor.
-
When you perform one of the following operations, enter the password and wait a few seconds until toolbox shows a successful prompt. (Password is not need if you connect it via type-C port)
- Turn on/off the sensor
- Reset the sensor
- Click “Write” to change settings
- Upgrade
Template Settings
Note: Template function is allowed only for sensors with the same model
and LoRa frequency band.
- Go to “Maintenance -> Template and Reset” page in Toolbox.
- Click “Export” to save the current settings as a template.
- Click “Browse” to select the correct template from computer.
- Click “Import” to import the template to the device.
Upgrade
- Download firmware on your computer.
- Go to “Maintenance -> Upgrade” page in Toolbox.
- Click “Browse” and select the firmware from computer.
- Click “Upgrade” to upgrade the device.
Note: If NFC connection is selected, please keep the two devices close and don’t move them in order to get the best connectivity as possible when upgrading.
Configuration Examples
LoRa Channel Settings
The configuration of LoRaWAN® channel of EM300 must match the gateway’s. Refer
to Appendix to check default channel settings of EM300.
Mobile APP Configuration:
Open Toolbox APP and go to “Device ->Setting -> LoRaWAN Settings” to change
the frequency and channels.
Software Configuration:
Log in Toolbox and go to “LoRaWAN Settings -> Channel” to change frequency and
channels.
Note: If frequency is one of CN470/AU915/US915, you can enter the index
of the channel that you want to enable in the input box, making them separated
by commas.
Examples:
1, 40: Enabling Channel 1 and Channel 40
1-40: Enabling Channel 1 to Channel 40
1-40, 60: Enabling Channel 1 to Channel 40 and Channel 60 All: Enabling all
channels
Null: Indicates that all channels are disabled
Alarm Settings
When water leakage sensor or magnet switch sensor is triggered, it will send
alarm message once by default. Toolbox allows users to change the alarm
reporting interval and reporting times.
Mobile APP Configuration:
Open Toolbox APP and go to “Device -> Setting -> Threshold Settings” to enable
the threshold settings and input the threshold.
Software Configuration:
Log in Toolbox and go to “Device Settings -> Basic -> Threshold Settings” to
enable the calibration and input the calibration value.
Installation
-
Attach EM300 to the wall and mark the two holes on the wall. The connecting line of two holes must be a horizontal line.
-
Drill the holes according to the marks and screw the wall plugs into the wall.
-
Mount the EM300 to the wall via mounting screws.
-
Cover the mounting screws with screw caps.
-
For leak detection senor, install the probe/cable to the place where liquid may leak. For magnet switch sensor, install the magnet beside the door/window.
Note: For SLD sensor, please ensure the metal pins of the probe are flat on the floor; for ZLD sensor, the cable can’t be twined or accumulated together. The probe or cable of water leakage sensor should be placed in an area of concern where water from a leak would likely accumulate.
Milesight IoT Cloud Management
EM300 sensors can be managed by Milesight IoT Cloud platform. Milesight IoT
cloud is a comprehensive platform that provides multiple services including
device remote management and data visualization with the easiest operation
procedures. Please register a Milesight IoT Cloud account before operating
following steps.
Milesight IoT Cloud URL: cloud.milesight-iot.com
Add a Milesight Gateway
-
Enable “Milesight” type network server and “Milesight IoT Cloud” mode in gateway web GUI.
Note: Ensure gateway has accessed the Internet.
-
Go to “My Devices” page and click “+New Devices” to add gateway to Milesight IoT Cloud via SN. Gateway will be added under “Gateways” menu.
-
Check if gateway is online in Milesight IoT Cloud.
Add EM300 to Milesight IoT Cloud
-
Go to “My Devices” page and click “+New Devices”. Fill in the SN of EM300 and select associated gateway.
-
After EM300 is connected to Milesight IoT Cloud, you could check the device information and data and create dashboard for it.
Sensor Payload
All data are based on following format:
Channel 1
| Type 1| Data 1| Channel 2| Type 2| Data 2| Channel 3| …
---|---|---|---|---|---|---|---
1 Byte| 1 Byte| N Bytes| 1 Byte| 1 Byte| M Bytes| 1 Byte|
…
Uplink Packet(HEX)
Channel
| Type| Data Example|
Description
---|---|---|---
01
|
75(Battery Level)
|
64
|
64=>100
Battery level =100%
03
|
67 (Temperature)
|
10 01
|
10 01 => 01 10 = 272
Temp=272*0.1=27.2°C
04
|
**** 68 (Humidity)
|
71
|
71=>113
Hum=113*0.5=56.5%
05
|
00
|
00
|
Not water leakage
01
|
Water leakage
06
|
00
|
00
|
Magnet switch closed
01
|
Magnet switch open
ff
|
01 (Milesight Protocol Version)
|
01
|
V1
08 (Device SN)
|
64 10 90 82 43 75 00 01
|
Device SN is 6410908243750001
09 (Hardware Version)
|
01 40
|
V1.4
0a(Software Version)
|
01 14
|
V1.14
0f(Device Type)
|
00
|
Class A
Downlink Packet (HEX)
Channel
| Type| Data Example|
Description
---|---|---|---
ff
| 03(Set Reporting Interval)| b0 04|
b0 04 => 04 b0 = 1200s
Appendix
Default LoRaWAN Parameters
DevEUI
|
24E124 + 2nd to 11th digits of SN e.g. SN = 61 26 A1 01 84 96 00 41
Then Device EUI = 24E124126A101849
---|---
AppEUI
|
24E124C0002A0001
Appport
|
0x55
NetID
|
0x010203
DevAddr
|
The 5th to 12th digits of SN
e.g. SN = 61 26 A1 01 84 96 00 41
Then DevAddr = A1018496
AppKey
|
5572404C696E6B4C6F52613230313823
NwkSKey
|
5572404C696E6B4C6F52613230313823
AppSKey
|
5572404C696E6B4C6F52613230313823
Default Uplink Channels
Model
| Channel Plan|
Channel Settings/MHz
---|---|---
EM300-470M
| CN470|
470.3~489.3(All 95 channels)
EM300-868M
| EU868| 868.1, 868.3, 868.5
RU864|
868.9, 869.1
IN865
|
865.0625, 865.4025, 865.6025
EM300-915M
|
AU915
| 915.2~927.1 (All 72 channels)
US915|
902.3~914.2 (All 72 channels)
KR920
|
922.1, 922.3, 922.5
AS923|
923.2, 923.4
References
Read User Manual Online (PDF format)