albinus BL10CM Series DC Driven Circulation Pumps with Brushless Motor Instruction Manual

June 4, 2024
albinus

Albinus BL10CM Series DC Driven Circulation Pumps with Brushless Motor

albinus-BL10CM-Series-DC-Driven-Circulation-Pumps-with-Brushless-Motor-
product

IEC 60335-1 EN 55014
EN/IEC 61000 RoHS Directive 2002/95/EG

Albin Group’s series of Albinus DC-driven Circulation Pumps are designed for circulation of water/antifreeze (max 60% glycol for a water/glycol mixture) in heating or cooling systems on boats, buses, motorhomes, and commercial vehicles. All-round pump with exceptionally long service lifetime, where self- priming is not essential.

  • Small size with high efficiency, maintenance-free
  • Ceramic Shaft and Carbon fibre sleeve
  • Completely waterproof (IP68)
  • Brushless DC control, long service life

Installation

Albinus’ DC-driven Circulation Pumps with Brushless Motor are normal-priming centrifugal pumps and as such must be installed so that they are always flooded, or must be primed before use. Install the pump at a low point – horizontally or vertically on a flat surface – to ensure a free flow of water to the pump. The pump may even be installed fully submerged.

  • In the case of vertical installation, avoid having the water inlet pointing upwards.
  • In the case of horizontal installation, avoid air-locks by turning the body in such a way that the outlet is directed upwards or placed on the upper side of the pump body (see drawing below).
  • The outlet hose from the pump must be horizontal or directed upwards to evacuate air.

Wiring dimensions
(Based on 3% voltage drop)

Wire size **Max wire length***
  13.6V
1.5 mm²
2.5 mm² 6.3 m
3 mm² 8 m
4 mm² 10m

Electrical Installation

Before connecting the pump to the power supply, make sure that the working voltage is correct for the pump in question; 12V or 24V.
Note! Before installation with electrical control systems, check that the equipment to be used is of sufficient rated capacity to accept the ampere draw of the motor.

  • Connect the Red lead to the Positive (+) terminal. Connect the Black lead to the Negative (–) terminal.
  • Ignition-protected fuse, switches, circuit breakers, etc must be installed between the pump and the Positive (+) terminal of the battery, on the Red lead.
  • For installation on a boat, all electrical connections must be placed above the highest water level. All wire connections should be sealed with a marine sealant, e.g. Vaseline, silicon rubber or grease.
  • Refer to the table above for wire sizes, depending on total wire length.

BL10CM-12 V, Part no. 13-01-005

 | Port Size| Capacity at 0.1 bar| Capacity at

0.25 bar

| Max. load current| Max Power consumption
---|---|---|---|---|---
BL10CM-12V| 14 mm (5/8″)| 19 l/min| 16 l/min| 2 A| 25 W
BL10CM-24V| 14 mm (5/8″)| 21 l/min| 18 l/min| 1.7 A| 40 W

Dimensions See Drawing
Ports Size Dia 14 mm (5/8″)
Weight 0.2 kg
Motor Brushless magnetic isolated design
Duty Continuous Duty
Life span 20 000 hours
Materials of the pump housing ABS, PES/SPS/PA66
Motor IP Classification IP 68
Noise class 35 dB
Max. Liquid Temp. Continuous Duty + 80 °C Intermitent + 100 °C.

albinus-BL10CM-Series-DC-Driven-Circulation-Pumps-with-Brushless-Motor-fig-
\(3\)

BL30CM-12 V, Part no. 13-01-001

albinus-BL10CM-Series-DC-Driven-Circulation-Pumps-with-Brushless-Motor-
fig-12

albinus-BL10CM-Series-DC-Driven-Circulation-Pumps-with-Brushless-Motor-fig-
\(4\)

Dimensions See Drawing
Ports Size Dia 20 mm (3/4″)
Weight 0.48 kg
Motor Brushless magnetic isolated design
Duty Continuous Duty
Life span 20 000 hours
Materials of the pump housing ABS, PES/SPS/PA66
Motor IP Classification IP 68
Noise class 35 dB
Max. Liquid Temp. Continuous Duty + 80 °C Intermitent + 100 °C.

BL90CM-12 V, Part no. 13-01-003

albinus-BL10CM-Series-DC-Driven-Circulation-Pumps-with-Brushless-Motor-
fig-13

Dimensions See Drawing
Ports Size Dia 20 mm (3/4″)
Weight 0.89 kg
Motor Brushless magnetic isolated design
Duty Continuous Duty
Life span 20 000 hours
Materials of the pump housing ABS, PES/SPS/PA66
Motor IP Classification IP 68
Noise class 35 dB
Max. Liquid Temp. Continuous Duty + 80 °C Intermitent + 100 °C.

BL110CM-12 V, Part no. 13-01-007

 | Port Size| Capacity at

0.1 bar

| Capacity at

0.25 bar

| Max. load current| Max Power consumption
---|---|---|---|---|---
BL110CM-12V| 38 mm (11/2″)| 97.5 l/min| 77.5 l/min| 5.4 A| 80 W
BL110CM-24V| 38 mm (11/2″)| 124.5 l/min| 110.5 l/min| 5.4 A| 150 W

Dimensions See Drawing
Ports Size Dia 38 mm (11/2″)
Weight 2.1 kg
Motor Brushless magnetic isolated design
Duty Continuous Duty
Life span 20 000 hours
Materials of the pump housing ABS, PES, SPS, PPS, PA66+30%GF(Optional)
Motor IP Classification IP 68
Noise class 35 dB
Max. Liquid Temp. Continuous Duty + 80 °C Intermittent + 100 °C

BL130CM-12 V, Part no. 13-01-009

albinus-BL10CM-Series-DC-Driven-Circulation-Pumps-with-Brushless-Motor-
fig-14

Dimensions See Drawing
Ports Size Dia 38 mm (11/2″)
Weight 3.2 kg
Motor Brushless magnetic isolated design
Duty Continuous Duty
Life span 20 000 hours
Materials of the pump housing ABS, PES, SPS, PPS, PA66+30%GF(Optional)
Motor IP Classification IP 68
Noise class 35 dB
Max. Liquid Temp. Continuous Duty + 80 °C Intermitent + 100 °C.

Cautionary Notes

  • Do not pump gasoline, solvents, thinner, seawater or other liquids with large suspended particles.
  • The pump should not be run dry, even if it withstands a shorter time of dry running. Max. dry running for 30 minutes. If it runs dry, noise may occur. Avoid dry running because it will always cause increased wear.
  • Use full hose diameter at the inlet. Reduced hose diameter at the inlet gives reduced performance and risk of cavitations which can cause damage to the pump. For Winter storage, disconnect the pump from the power supply and drain any remaining liquid in the pump

Separate Order Speed Control configurations
Albinus’ DC-driven Circulation Pumps with Brushless Motor come with a wiring harness and DC-controller, in standard configuration. The pumps can also be ordered in the following, optional, Speed Regulation configurations; with wiring harness and integrated DC/ Speed controller.

Waste handling & material recycling
At the product’s end of life, please dispose of the product according to applicable law. Where applicable, please disassemble the product and recycle the parts according to the material.

Albin Group Marine AB
Kämpevägen 17
55302 Jönköping, Sweden
info@albin.group
www.albin.group

Read User Manual Online (PDF format)