Milesight UR32L Lite Industrial Cellular Router User Guide

June 6, 2024
Milesight

Milesight UR32L Lite Industrial Cellular Router User Guide

Welcome

Thank you for choosing Milesight UR32L industrial cellular router. This guide describes how to install the UR32L and how to log in the Web GUI to configure the device. Once you complete the installation, refer to the Milesight UR32L User Guide for instructions on how to perform configurations on the device.

Packing List

Before you begin to install the UR32L router, please check the package contents to verify that you have received the items below.

  • 1 × UR32L
    Packing List

  • 1 × Ethernet Cable
    Packing List

  • 1 × Power Adapter
    Packing List

  • 1 × Magnetic Cellular Antenna
    Packing List

  • 1 × DIN Rail Kit
    Packing List

  • Setscrews
    Packing List

  • 1 × Warranty Card
    Packing List

  • 1 × Quick Start Guide
    Packing List

  • 1 × Stubby Cellular Antenna (Optional)
    Packing List

If any of the above items is missing or damaged, please contact your sales representative.

Hardware Introduction

Overview

Product Overview

  1. Cellular Antenna Connector
  2. LED Indicator Area
  3. POWER: Power Indicator
  4. SYSTEM: Status Indicator
  5. SIM : Status Indicator
  6. : Signal Strength Indicator
  7. Ethernet LAN1/WAN Port
  8. Ethernet LAN2 Port
  9. Power Connector
  10. SIM and Reset Button Holder
Dimensions (mm)

Dimensions

LED Indicators
LED Indication Status Description
POWER Power Status Off The power is switched off
On The power is switched on
SYSTEM System Status Green Light Static: Start-up

Blinking slowly: the system is running properly
Red Light| The system goes wrong
SIM| SIM Card Status| Off| SIM is registering or fails to register (or there are no SIM cards inserted)
Green Light| Blinking slowly: SIM has been registered and is ready for dial-up
Blinking rapidly: SIM has been registered and is dialing up now
Static:    SIM    has    been   registered   and    dialed   up successfully
Signal Strength| Signal 1/2/3| Off| No signal
Green Light| Static/Off/Off: weak signals with 1-10 ASU (please check if the antenna is installed correctly, or move the antenna to a suitable location to get better signal)
Static/Static/Off:   normal    signals    with   11-20    ASU (average signal strength)
Static/Static/Static: strong signals with 21-31 ASU (signal is good)

Reset Button

Reset button is under the SIM slot.

Function

| Description
---|---
SYSTEM LED|

Action

Reset

| Blinking| Press and hold the reset button for more than 5 seconds.
Static Green → Rapidly Blinking| Release the button and wait.
Off → Blinking| The router is now reset to factory defaults.

Ethernet Port Indicator

Indicator

| Status|

Description

---|---|---

Link Indicator (Orange)

| On| Connected

Blinking

|

Transmitting data

Off|

Disconnected

Hardware Installation

SIM Card Installation
  1. Unscrew the cover of the SIM card then take it off.

  2. Put SIM card into the slot and screw it up.
    SIM Card Installation

Antenna Installation

Rotate the antenna into the antenna connector accordingly.The external antenna should be installed vertically always on a site with a good signal.

Antenna Installation

Router Installation

The router can be placed on a desktop or mounted to a wall or a DIN rail.

Wall Mounting (Measured in mm)

Use 4 pcs of M3 × 6 flat head Phillips screws to fix the router on the wall.

Recommended torque for mounting is 1.0 N·m, and the maximum allowed is 1.2 N·m.

Wall Mounting

DIN Rail Mounting (Measured in mm)

Use 2 pcs of M3 × 6 flat head Phillips screws to fix the mount clip to the router, and then hang the device to the DIN rail. The width of DIN rail is 3.5cm.

Recommended torque for mounting is 1.0 N·m, and the maximum allowed is 1.2 N·m.

Log in the Web GUI of Router

PC Configuration

Please connect PC to LAN port of UR32L router. PC can obtain an IP address, or you can configure a static IP address manually. The following steps are based on Windows 10 operating system for your reference.

(Note: As remote access is disabled by default, you can’t access to the router’s Web GUI if you connect PC to WAN port of the router. But it will function properly if you enable it on Web GUI.)

  1. Click “Search Box” to search “Control Panel” on the Windows 10 taskbar.
    PC Configuration

  2. Click “Control Panel” to open it, and then click “View network status and tasks”.
    PC Configuration

  3. Click “Ethernet” (May have different names).
    PC Configuration

  4. Click “Properties”.
    PC Configuration

  5. Double Click “Internet Protocol Version 4 (TCP/IPv4)” to configure IP address and DNS server.

  6. Method 1: click “Obtain an IP address automatically”;

  7. Method 2: click “Use the following IP address” to assign a static IP manually within the same subnet of the router.

(Note: Remember to click “OK” to finish configuration.)

Log in the Router

If this is the first time you configure the router, please use the default settings below:

IP Address: 192.168.1.1
Username: admin
Password: password

  1. Start a Web browser on your PC (Chrome is recommended), type in the IP address, and press Enter on
    your keyboard.

  2. Enter the username and password, click “Login”.
    Log in the Router
    If you enter the username or password incorrectly more than 5 times, the login page will be locked for 10 minutes.

  3. When you log in with the default username and password, you will be asked to modify the password. It’s suggested that you change the password for the sake of security. Click “Cancel” button if you want to modify it later.
    Changing Password Interface

  4. After you log in the Web GUI, you can view system information and perform configuration on the router.
    Milesight Web GUI

Network Configuration

This chapter explains how to connect UR32L to network via WAN connection or cellular.

Ethernet WAN Configuration
  1. Go to “Network > Interface > Port” to change LAN1 to WAN port.
    Ethernet WAN Configuration

  2. Go to “Network > Interface > WAN” to configure WAN parameters. Take static IP configuration as an example. DHCP client and PPPoE type are optional according to your requirements.
    Ethernet WAN Configuration
    Click “Save & Apply” button to make the changes take effect.

  3. Connect WAN port to another router or modem.

  4. Log in UR32L web GUI via WAN port IP address and go to “Status > Network” to check if status is “up”.
    Ethernet WAN Configuration

  5. Go to “Network > Interface > Link Failover” to rise the WAN priority to 1.
    Ethernet WAN Configuration

  6. Open your preferred browser on PC, then type any available web address into address bar and see if it is able to visit Internet via UR32L router.

Cellular Connection Configuration
  1. Click “Network > Interface > Cellular > Cellular Setting” to configure the cellular info, like APN and network type.

  2. Click “Save” and “Apply” for configuration to take effect.
    Cellular Connection Configuration
    If you select “Auto”, the router will obtain ISP information from SIM card to set APN, Username, and Password automatically. This option will only be taken effect when the SIM card is issued from a well-known ISP.

  3. Go to “Network > Interface > Link Failover” to enable SIM and rise link priority.
    Cellular Connection Configuration

  4. Click  to configure ICMP ping detection information.
    Cellular Connection Configuration

  5. Click “Status > Cellular” to view the status of the cellular connection. If it shows “Connected”, it means SIM has dialed up successfully.
    On the other hand, you can check the status of SIM indicator. If it keeps on green light statically, it means SIM has dialed up successfully.
    Cellular Connection Configuration

  6. Open your preferred browser on PC, then type any available web address into address bar and see if it is able to visit Internet via UR32L router.

Related Documents

Document

|

Description

---|---
UR32L Datasheet| Datasheet for UR32L industrial cellular router.
UR32L User Guide| Instruction on how to log in the web GUI, and how to configure all the settings.

Declaration of Conformity

UR32L are in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS

Icons

Copyright © 2011-2021 Milesight.All rights reserved. All information in this guide is protected by copyright law. Whereby, no organization or individual shall copy or reproduce the whole or part of this user guide by any means without written authorization from Xiamen Milesight IoT Co., Ltd.

Getting Help IconFor assistance, please contact Milesight technical support:
Email: iot.support@milesight.com
Tel: 86-592-5085280
Fax: 86-592-5023065

Revision History

Date

| Doc Version| Description
---|---|---
Apr. 13, 2021| V 1.0|

Initial version

www.milesight-iot.com

Milesight logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals