Welcome
Thank you for choosing the Milesight UR32 industrial cellular router.
This guide describes how to install the UR32 and how to log in to the Web GUI to configure the device.
Once you complete the installation, refer to the Milesight UR32 User Guide for instructions on how to perform configurations on the device.
Related Documents
This Start Guide only explains the installation of the Milesight UR32 router. For more functionality and advanced settings, please refer to the relevant documents as below.

Document Description
UR32 Datasheet Datasheet for UR32 industrial cellular router.
UR32 User Guide Users could refer to the guide for instruction on how to log

in the web GUI, and how to configure all the settings.

The related documents are available on the Milesight website: https://www .milesight-iot.com
Declaration of Conformity
UR32 are in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS.

Milesight UR32 GPS MicroSD Dual SIM Industrial Router -
ce

© 2011-2021 Xiamen Milesight IoT Co., Ltd.
All rights reserved.
All information in this guide is protected by copyright law. Whereby, no organization or individual shall copy or reproduce the whole or part of this user guide by any means without written authorization from Xiamen Milesight IoT Co., Ltd.

Milesight UR32 GPS MicroSD Dual SIM Industrial Router - All rights
reservedFor assistance, please contact
Milesight technical support:
Email: iot.support@milesight.com
Tel: 86-592-5085280
Fax: 86-592-5023065
Revision History

Date Doc Version Description
Aug. 1, 2019 V 1.0 Initial version
Feb. 11, 2020 V 1.1 1. Replace serial port picture;

2. Delete reboot descriptions of reset button
Aug. 26, 2020| V 1.2| 1. Web GUI change; 2.Add -485 model
Nov. 20, 2020| V 2.0| Layout replace

Packing List

Before you begin to install the UR35 router, please check the package contents to verify that you have received the items below.

Milesight UR35 Dual SIM Industrial Router-Packing List

**** If any of the above items is missing or damaged, please contact your sales representative.

Hardware Introduction

Overview

A. Front PaneMilesight UR35 Dual SIM Industrial Router-Front
Panel

1. Wi-Fi Antenna Connector
2. AUX Antenna Cellular Connector
3. GPS Antenna Connector
4. MAIN Cellular Antenna Connector| 5. LED Indicator Area
POWER: Power Indicator
SYSTEM: Status Indicator
Wi-Fi: Wi-Fi Indicator
VPN: VPN Indicator
SIM: SIM Status Indicator
: Signal Strength Indicator
6. Ethernet Port & Indicator
---|---

B. Left Side PanelMilesight UR35 Dual SIM Industrial Router-Left Side
Panel7. Grounding Stud
8. SIM and Reset Button Holder
9. Power Connector
10. Serial Port & I/O

Dimensions (mm)

Milesight UR35 Dual SIM Industrial Router-Dimensions

Connectors
PIN RS232 RS485 DI DO Description
1 IN Digital Input
2 GND GND Ground
3 B Data –
4 TXD Transmit Data
5 COM Common Ground
6 OUT Digital Output
7 A Data +
8 RXD Receive Data

Note : For -RS485 model, RXD—>A, TXD—>B.

PIN Description
9 Positive
10 Negative
LED Indicators
LED Indication Status Description
POWER Power Status Off The power is switched off
On The power is switched on
SYSTEM System Status Green Light Static: Start-up

Blinking slowly: the system is running properly
Red Light| The system goes wrong
VPN| VPN Status| Off| VPN is disconnected
Green Light| VPN is connected
Wi-Fi| Wi-Fi Status| Off| Wi-Fi is disabled
Green Light| Static: Wi-Fi is enabled
SIM| SIM Card Status| Blinking slowly: sending or receiving data via Wi-Fi
Off| SIM1 or SIM2 is registering or fails to register (or there are no SIM cards inserted)
Green Light| Blinking slowly: SIM1 (as primary SIM) has been registered and is ready for dial-up
Blinking rapidly: SIM1(as primary SIM) has been registered and is dialing up now
Static: SIM1 (as primary SIM) has been registered and dialed up successfully
Orange Light| Blinking slowly: SIM2 (as primary SIM) has been registered and is ready for dial-up
Blinking rapidly: SIM2 (as primary SIM) has been registered and is dialing up now
Static: SIM2 (as primary SIM) has been registered and dialed up successfully
Signal Strength| Signal 1/2/3| Off| No signal
Green Light| Static/Off/Off: weak signals with 1-10 ASU (please check if the antenna is installed correctly, or move the antenna to a suitable location to get a better signal)
Static/Static/Off: normal signals with 11-20 ASU (average signal strength)
Static/Static/Static: strong signals with 21-31 ASU (signal is good)

Reset Button

Reset button is under the SIM slots.

Function Description
SYSTEM LED Action
Reset Blinking
Static Green → Rapidly Blinking Release the button and wait.
Off → Blinking The router is now reset to factory defaults.
Ethernet Port Indicator
Indicator Status Description
Link Indicator (Orange) On Connected
Blinking Transmitting data
Off Disconnected

Hardware Installation

Environmental Requirements
– Power Input: 9-48 VDC (48 VDC is needed for PoE output)
– Power Consumption: Typical 3.9W (Max 4.6 W)
– Operating Temperature: -40°C to 70°C (-40°F -158°F)
– Relative Humidity: 0% to 95% (non-condensing) at 25°C/77°F

SIM Card/Micro SD Card Installation

**** UR35 do not support hot-plug. Please cut off the power before insert or take off cards.

A. Unscrew the cover of the SIM card/Micro SD then insert the card then take it off.
B. Put SIM card/Micro SD card into the slot and screw it up.Milesight UR35
Dual SIM Industrial Router-SD Card Installation

Antenna Installation

Rotate the antenna into the antenna connector accordingly.
The external antenna should be installed vertically always on a site with a good signal.Milesight UR35 Dual SIM Industrial Router-SD Card Installation
2

Router Installation

The router can be placed on a desktop or mounted to a wall or a DIN rail.
3.4.1 Wall Mounting (Measured in mm)
Use 2 pcs of M3 × 6 flat head Phillips screws to fix the wall mounting kit to the router, and then use 2 pcs of M3 drywall screws to mount the router associated with the wall mounting kit on the wall.
Recommended torque for mounting is 1.0 N·m, and the maximum allowed is 1.2 N·m.Milesight UR35 Dual SIM Industrial Router-maximum
allowe 3.4.2 DIN Rail Mounting (Measured in mm)
Use 2 pcs of M3 × 6 flat head Phillips screws to fix the DIN rail to the router, and then hang the DIN rail on the mounting bracket. It is necessary to choose a standard bracket.
Recommended torque for mounting is 1.0 N·m, and the maximum allowed is 1.2 N·m.

**Protective Grounding Installation

**

A. Remove the grounding nut.
B. Connect the grounding ring of the cabinet’s grounding wire onto the grounding stud and screw up the grounding nut.Milesight UR35 Dual SIM
Industrial Router-Grounding Installation **** The router must be grounded when deployed. According to the operating environment, the ground wire should be connected with the grounding stud of the router.

Log in the Web GUI of Router

PC Configuration

Please connect PC to any port among LAN1-LAN4 of UR35 router. PC can obtain an IP address, or you can configure a static IP address manually. The following steps are based on Windows 10 operating system for your reference.
( Note : As remote access is disabled by default, you can’t access to the router’s Web GUI if you connect PC to the WAN port of the router. But it will function properly if you enable it on Web GUI.) ① Click “Search Box” to search “Control Panel” on the Windows 10 taskbar.
② Click “Control Panel” to open it, and then click “View network status and tasks”.Milesight UR35 Dual SIM Industrial Router-PC Configuration
2③ Click “Ethernet” (May have different names).
④ Click “Properties”.Milesight UR35 Dual SIM Industrial Router-PC
Configuration 3⑤ Double Click “Internet Protocol Version 4 (TCP/IPv4)” to configure IP address and DNS server.
⑥ Method 1: click “Obtain an IP address automatically”;
Method 2: Click “Use the following IP address” to assign a static IP manually within the same subnet of the router.
(Note: Remember to click “OK” to finish the configuration.)

Log in the Router

If this is the first time you configure the router, please use the default settings below:
IP Address: 192.168.1.1
Username: admin
Password: password
A. Start a Web browser on your PC (Chrome is recommended), type in the IP address, and press Enter on your keyboard.
B. Enter the username and password, click “Login”.Milesight UR35 Dual SIM
Industrial Router-username and password **** If you enter the username or password incorrectly more than 5 times, the login page will be locked for 10 minutes.
C. When you log in with the default username and password, you will be asked to modify the password.
It’s suggested that you change the password for the sake of security. Click the “Cancel” button if you want to modify it later.Milesight UR35 Dual SIM
Industrial Router-CancelD. After you log in the Web GUI, you can view system information and perform configuration on the router.Milesight UR35 Dual SIM Industrial Router-ystem
information

Network Configuration

This chapter explains how to connect UR35 to the network via WAN connection or cellular.

Ethernet WAN Configuration

A. Go to “Network > Interface > WAN” to configure WAN parameters. Take static IP configuration as an example. DHCP client and PPPoE type are optional according to your requirements.Milesight UR35 Dual SIM Industrial Router-WAN
Configuration

Click “Save & Apply” button to make the changes take effect.

B. Connect WAN port to another router or modem.

C. Log in UR35 web GUI via WAN port IP address and go to “Status > Network” to check if status is “up”.Milesight UR35 Dual SIM Industrial Router-outer or
modemD. Go to “Network > Interface

Link Failover” to rise the WAN priority to 1.Milesight UR35 Dual SIM
Industrial Router-priority of SIM1

E. Open your preferred browser on PC, then type any available web address into the address bar and see if it is able to visit the Internet via UR35 router.

Cellular Connection Configuration

Take inserting SIM card into SIM1 slot as an example; please refer to the following detailed operations.
A. Click “Network > Interface > Cellular > Cellular Setting” to configure the cellular info, like APN and network type.
B. Click “Save” and “Apply” for configuration to take effect. Milesight UR35
Dual SIM Industrial Router-Connection ConfigurationIf you select “Auto”, the router will obtain ISP information from SIM card to set APN, Username, and Password automatically. This option will only be taken effect when the SIM card is issued from a well- known ISP.
C. Go to “Network > Interface > Link Failover” to enable SIM1 and rise link priority of SIM1.Milesight UR35 Dual SIM Industrial Router-WAN
priorityD. Click to configure ICMP ping detection information.Milesight UR35 Dual SIM Industrial Router-detection
information E. Click “Status > Cellular” to view the status of the cellular connection. If it shows “Connected”, it means SIM1 has dialed up successfully.
On the other hand, you can check the status of SIM indicator. If it keeps on green light statically, it means SIM1 has dialed up successfully.

F. Open your preferred browser on PC, then type any available web address into the address bar and see if it is able to visit the Internet via the UR35 router.
www.milesight-iot.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals