TRIPP-LITE PDUH30HV19 PDU Basic Rack Owner’s Manual
- June 6, 2024
- Tripp Lite
Table of Contents
Owner’s Manual
Basic Rack PDU
PDUH30HV19
(Series Number: AG-00E6)
PDUH30HV
(Series Number: AG-00E6)| PDUH32HV19
(Series Number: AG-00E5)
PDUH32HV
(Series Number: AG-00E5)
---|---
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector— a $100 value!
www.tripplite.com/warranty
http://www.tripplite.com/warranty
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during
the installation, operation and storage of this product. Failure to heed these
instructions and warnings will void the product warranty.
CAUTION Only those who are properly trained or qualified to use this device
should do so. Anyone who is not trained or qualified should not use this
device unless it is under the supervision of someone who is properly trained
or qualified to do so. Children must be supervised to ensure that they do not
use the device as a toy. Never use the device if the cord and plug are
damaged; if it is not working properly, or if it has been dropped or damaged,
take it to an authorized service center for inspection and repair.
If the power cord is damaged, it must be replaced by the manufacturer, its
authorized service agent, or by qualified personnel in order to avoid danger.
Important Warnings
- The PDU provides the convenience of multiple outlets but DOES NOT provide surge or line noise protection for connected equipment.
- The PDU is designed for indoor use only, in a controlled environment, away from excess moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
- Keep the indoor ambient temperature between 32°F and 104°F (0°C and 40°C).
- The PDU must be installed by a qualified technician only.
- Do not attempt to mount the PDU to an insecure or unstable surface.
- Install in accordance with National Electrical Code standards. Be sure to use the proper overcurrent protection for the installation, in accordance with the plug/equipment rating.
- Connect the PDU to an outlet that is in accordance with your local building codes and that is adequately protected against excess currents, short circuits, and earth faults.
- The electrical outlets supplying power to the equipment should be installed near the equipment and easily accessible.
- Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that eliminate the connection to the ground.
- Be sure to provide a local disconnect device on any models that are permanently installed without a plug that is easily accessible.
- Never attempt to install electrical equipment during a thunderstorm.
- Individual equipment connected to the PDU should not draw more current than the individual PDU’s outlet’s rating.
- The total load connected to the PDU must not exceed the maximum load rating for the PDU.
- Do not attempt to modify the PDU, input plugs, or power cables.
- Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable parts inside.
- Do not attempt to use the PDU if any part of it becomes damaged.
- Use of this equipment in life support applications where the failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen, or nitrous oxide.
Installation
Note: The illustrations may differ somewhat from your PDU model.
1.
Determine Installation Configuration. The PDU supports four primary
installation configurations: 1U Rack, 0U Rack, Wall, and Under-Counter. Choose
a configuration and follow the installation instructions in the appropriate
section of Step 1 before proceeding to Step 2.
Note : Regardless of installation configuration, the user must determine the
fitness of hardware and procedures before mounting.
The PDU and included hardware are designed for a common rack and rack
enclosure types and may not be appropriate for all applications. Exact
mounting configurations may vary.
1-1
1U Rack Installation. Attach the PDU to the rack by inserting four
user-supplied screws (A) through the PDU mounting brackets (B) and into the
mounting holes of the rack rail as shown. 1-2
OU Rack Installation. Part 1: Remove the screws (C)
attaching the mounting brackets to the PDU, change the orientation of the
brackets as shown, and reattach the brackets.
Use only the screws supplied by the manufacturer or their exact equivalent
(#6-32, 1/4” flat head). Part 2: Attach the PDU vertically by inserting two or
more user-supplied screws (A) through the PDU mounting brackets (B) and into
mounting points in the rack or rack enclosure.
1-3
Wall Installation. After repeating Part 1 above, attach the PDU to
a stable mounting surface by inserting two or more user-supplied screws (A)
through the PDU mounting brackets (B) and into secure mounting points on the
mounting surface. 1-4
Under-
Counter Installation. After repeating Part 1 above, attach the PDU to a
stable mounting surface by inserting four user-supplied screws (A) through the
PDU mounting brackets (B) and into secure mounting points on the mounting
surface.
2.
Attach the input plug of the PDU to a grounded outlet. Insert the
plug directly into a grounded outlet that does not share a circuit with a
heavy electrical load (such as an air conditioner or refrigerator). 3.
Attach equipment to the PDU. Do not exceed the load
rating of the PDU. The total electrical current used by the PDU will be
displayed on the digital meter in amperes.
Features
| L6-30P Input Plug:
200-240V
(PDUH30HV19
& PDUH30HV)| | 200-240V IEC 60320
C13 Output Receptacles
(PDUH30HV &
PDUH32HV)
---|---|---|---
| IEC 309 Blue 32A
Input Plug: 200-240V(PDUH32HV19 &
PDUH32HV)
1.
| | 200-240V IEC 60320
C19 Output Receptacles
(PDUH30HV19 &
PDUH32HV19)
2.
- Input Plug (Varies by Model)
- Outlets (Vary by Model): During normal operation, the outlets distribute AC power to connected equipment.
- Circuit Breaker: If the current drawn by the equipment connected to the PDU exceeds the Maximum Current Rating, the circuit breaker will trip to prevent possible damage. When a circuit breaker trips, its rocker will pop up. Disconnect excess equipment and allow the breaker to cool at least one minute before depressing the rocker to reset the breaker.
- Grounding Lug: Use this terminal to connect any equipment that requires a chassis ground.
Warranty & Product Registration
LIMITED WARRANTY
Seller warrants this product, if used in accordance with all applicable
instructions, to be free from original defects in material and
workmanship for a period of 5 years (except internal UPS system batteries
outside USA and Canada, 1 year) from the date of initial purchase. If the
product should prove defective in material or workmanship within that period,
Seller will repair or replace the product, in its sole discretion. Service
under this Warranty can only be obtained by your delivering or shipping the
product (with all shipping or delivery charges prepaid) to: Tripp Lite, 1111
W. 35th Street, Chicago, IL 60609 USA. Seller will pay return shipping
charges. Visit www.tripplite.com/support
before sending any equipment back for repair.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM
ACCIDENT, MISUSE, ABUSE OR NEGLECT.
SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH
HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED
WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE
LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; THIS WARRANTY
EXPRESSLY EXCLUDES ALL INCIDENTAL
AND CONSEQUENTIAL DAMAGES. (Some states do not allow limitations on how long
an implied warranty lasts, and some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitations or
exclusions may not apply to you. This Warranty gives you specific legal
rights, and you may have other rights which vary from jurisdiction to
jurisdiction).
WARNING: The individual user should take care to determine prior to use
whether this device is suitable, adequate or safe for the use intended. Since
individual applications are subject to great variation, the manufacturer makes
no representation or warranty as to the suitability or fitness of these
devices for any specific application.
PRODUCT REGISTRATION
Visit www.tripplite.com/warranty today to
register your new Tripp Lite product. You’ll be automatically entered into a
drawing for a chance to win a FREE Tripp Lite product!*
- No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique serial number. The serial number can be found on the product nameplate label, along with all required approval markings and information.
When requesting compliance information for this product, always refer to the series number. The series number should not be confused with the marking name or model number of the product.
The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
1111 W. 35th Street, Chicago, IL 60609 USA •www.tripplite.com/support
Read User Manual Online (PDF format)