Wiring center extension for KL08RF 24V
Model: KL04RF 24V

SALUS Wiring Centre Extension for KL08RF 24V

Manual

Wiring Centre Description

  1. Serial Connector + power supply from the main wiring center
  2. Connection diode
  3. Work status indication of each zone
  4. Output terminals for actuators

SALUS Wiring Centre Extension for KL08RF 24V - Centre

Introduction

The KL04RF 24V module is an extension to the KL08RF 24V wiring center for an additional 4 heating zones. Works only in combination with KL08RF 24V wiring center and increases its functionality up to 12 individual heating zones.

Product Compliance

This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU, Radio directive 2014/53/EU, and RoHS directive 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com

Safety Information

Use in accordance with national and EU regulations. The device is intended for indoor use only in dry conditions. Product for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.
Before attempting to set up and install, make sure that KL04RF 24V is not connected to any power source.
Installation must be carried out by a qualified person. Incorrect installation may cause damage to the wiring center. The KL04RF 24V should not be installed in areas where it may be exposed to water or damp conditions.

Technical Information

Power Supply From KLO8RF 24V wiring center
Max load 3 A
Outputs 24 V AC
Dimensions [mm] 163 x 85 x 67
  1. Serial connector
    It is used for communication between KL08RF 24V wiring center and KL04RF 24V extension module. Combined set increases support up to 12 zones.
    SALUS Wiring Centre Extension for KL08RF 24V -
connector

  2. Power supply
    The KL04RF 24V extension module is powered via the serial connector that connects the module to the KL08RF 24V wiring
    center. For the wiring center KL08RF 24V with the KL04RF 24V extension module, you can choose up to 12 actuators (use 24V actuators). 9 10 11 12

  3. Connection diode
    If KL04RF 24V module is properly connected to the KL08RF 24V wiring center, the connection diode will light solid red. KL04NSB

  4. Work status indication of each zone
    Green led diode lights up when the heating demand signal is being transmitted from the thermostat to the given zone (with NC actuators connected).
    SALUS Wiring Centre Extension for KL08RF 24V - NC

  5. Output terminals for actuators
    Wires of the thermoelectric actuators should be plugged into the self-locking connectors in the appropriate zones. You can connect 3 actuators directly to one zone. The current load of one zone is adapted to operate with up to 6 thermoelectric actuators with a power of 2 Watts. If there is a need to connect more than 6 actuators please use an additional relay to relieve the output of the zone.
    Up to 24 actuators can be connected to the wiring center KL08RF 24V with the KL04RF 24V extension module.
    SALUS Wiring Centre Extension for KL08RF 24V - thermoelectric
1 Note: On the actuator contacts, there is voltage 230 V AC during their work.
    The operation was explained in the example of T30NC actuators.

INSTALLATION

SALUS Wiring Centre Extension for KL08RF 24V - top
cover

Remove the top cover of the KL04RF 24V.

SALUS Wiring Centre Extension for KL08RF 24V - DIN
rail

Mount the backside of the housing to the wall.
When mounting on a DIN rail, open the hooks on the back of the housing.

SALUS Wiring Centre Extension for KL08RF 24V -
thermoelectric

Connect the thermoelectric actuators wires.

SALUS Wiring Centre Extension for KL08RF 24V - serial connector
1

Connect KL08RF 24V and KL04RF 24V using serial connector

SALUS Wiring Centre Extension for KL08RF 24V - wiring
centre

Make sure that all the wires are properly connected, mount the top cover, and power up the wiring center – “Power” and “Connection” red LED diodes will light up indicating the correct connection with the KL08RF 24V wiring center.

IMPORTER:
QL CONTROLS Sp. z o.o. Sp. k. ul. Rolna 4, 43-262 Kobielice
PRODUCER:

Salus Limited
6/F, Building 20E, Phase 3, Hong Kong Science
Park, 20 Science Park East Avenue, Shatin,
New Territories, Hong Kong

www.salus-controls.eu
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserves the right