TANDEM Diabetes Care X2 Insulin Pump User Guide
- June 13, 2024
- TANDEM Diabetes Care
Table of Contents
T:SLIM X2 INSULIN
PUMP
Control-IQ Technology
X2 Insulin Pump
This Quick Reference Sheet will teach you how to turn Control‑IQ technology on. Flip to the back to learn how Control‑IQ technology adjusts insulin delivery.
From
the Home screen, tap OPTIONS.
⚑ Note: These instructions are provided as a reference tool for pump
users and caregivers who are already familiar with the use of an insulin pump
and with insulin therapy in general. Not all screens are shown. For more
detailed information on the operation of the t:slim X2 pump, please refer to
its user guide.Tap My Pump.Tap Control-IQ.
Pump Tip: Existing users can tap Options, the down arrow, History, Pump
History, Delivery Summary, and then 14 Day Average to find their average Total
Insulin.Toggle Control‑IQ on.
⚑ Note: User must have an active Personal Profile with CARBS turned on and
an active CGMsession to turn Control-IQ technology on.Enter the user’s weight
and average daily insulin use.
⚑ Note: Total Daily Insulin should be an estimate of the total basal and
bolus insulin the user requires in a 24-hour period. Tap to save the settings.
Tap the Tandem logo on theface of the pump to return to the Home
screen.Control‑IQ technology is on.
Explanation of Icons
Insulin Adjustments | A | B |
---|---|---|
Delivers basal rate from Personal Profile | ||
Increases basal insulin delivery | ||
Delivers an automatic correction bolus† | ||
Decreases basal insulin delivery | ||
Stops basal insulin delivery | ||
Activity States | C | |
--- | --- | |
Sleep Activity enabled | ||
Exercise Activity enabled |
† If glucose values are predicted to be above 180 mg/dL, Control-IQ technology calculates a correction bolus using the Personal Profile settings and a target of 110 mg/dL and delivers 60% of that value. An Automatic Correction Bolus will not occur within 60 minutes of a bolus that has been delivered or canceled.
Activity Settings
Control-IQ technology features two optional settings that adjust treatment
ranges for more targeted control.
✓ When the Sleep Activity is enabled, the system narrows and lowers the range
of treatment values to 112.5-120 mg/dL.
✓ When the Exercise Activity is enabled, a tighter and higher range of
treatment values from 140-160 mg/dL is used.
Pump Tip: Automatic correction boluses† will not be delivered while Sleep
is enabled but can be delivered once per hour when the Exercise Activity is
enabled.
Responsible Use of Control-IQ Technology
Control-IQ technology does not prevent all high and low blood glucose events,
and is not a substitute for meal boluses and active self-management of your
diabetes. Control-IQ technology will not be able to predict sensor glucose
values and adjust insulin dosing if your CGM is not working properly or is
unable to communicate with your pump. Always pay attention to your symptoms
and blood glucose levels and treat accordingly.
Please visit
tandemdiabetes.com/tslimX2-use for
more information.
https://support.tandemdiabetes.com/
Need additional help? Scan this code to visit our support center.
How it Works
The t:slim X2 insulin pump with Control‑IQ technology uses continuous glucose
monitoring (CGM) values to predict glucose levels 30 minutes ahead and
automatically adjust insulin every 5 minutes. This powerful algorithm can
decrease or stop basal insulin delivery to help prevent lows. It can also
increase insulin delivery and deliver automatic correction boluses † ( ) to
help avoid highs. * CGM sold separately.
Important Safety Information: RX ONLY. The t:slim X2 pump and Control-IQ
technology are intended for single patient use. The t:slim X2 pump and
Control-IQ technology are indicated for use with U-100 insulin only. t:slim X2
insulin pump: The t:slim X2 insulin pump with interoperable technology is an
alternate controller enabled (ACE) pump that is intended for the subcutaneous
delivery of insulin, at set and variable rates, for the management of diabetes
mellitus in people requiring insulin. The pump is able to reliably and
securely communicate with compatible, digitally connected devices, including
automated insulin dosing software, to receive, execute, and confirm commands
from these devices. The t:slim X2 pump is indicated for use in individuals six
years of age and greater.
Control-IQ technology: Control-IQ technology is intended for use with a
compatible integrated continuous glucose monitor (iCGM, sold separately) and
ACE pump to automatically increase, decrease, and suspend delivery of basal
insulin based on iCGM readings and predicted glucose values. It can also
deliver correction boluses when the glucose value is predicted to exceed a
predefined threshold. Control-IQ technology is intended for the management of
Type 1 diabetes mellitus in persons six years of age and greater.
WARNING: Control-IQ technology should not be used by anyone under the age
of six years old. It should also not be used in patients who require less than
10 units of insulin per day or who weigh less than 55 pounds.
Control-IQ technology is not indicated for use in pregnant women, people on
dialysis, or critically ill patients. Do not use Control-IQ technology if
using hydroxyurea. Users of the t:slim X2 pump and Control-IQ technology must:
use the insulin pump, CGM, and all other system components in accordance with
their respective instructions for use; test blood glucose levels as
recommended by their healthcare provider; demonstrate adequate carb-counting
skills; maintain sufficient diabetes self-care skills; see healthcare
provider(s) regularly; and have adequate vision and/or hearing to recognize
all functions of the pump, including alerts, alarms, and reminders. The t:slim
X2 pump, and the CGM transmitter and sensor must be removed before MRI, CT, or
diathermy treatment. Visit
tandemdiabetes.com/safetyinfo for
additional important safety information.
© 2023 Tandem Diabetes Care, Inc. All rights reserved. Tandem Diabetes Care,
the Tandem logo, Control-IQ, and t:slim X2 are either registered trademarks or
trademarks of Tandem Diabetes Care, Inc. in the United States and/or other
countries. ML-1004929_E
877-801-6901
FOR USE IN THE
tandemdiabetes.com
UNITED STATES ONLY
Documents / Resources
|
TANDEM Diabetes Care X2 Insulin
Pump
[pdf] User Guide
X2, X2 Insulin Pump, Insulin Pump, Pump
---|---
References
- Diabetes Management | Insulin Pumps | Tandem Diabetes Care
- Diabetes Management | Insulin Pumps | Tandem Diabetes Care
- Important Safety Information - Tandem Insulin Pumps
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>