Combisteel 7072 Series Chest Freezer User Manual
- June 13, 2024
- CombiSteel
Table of Contents
Chest Freezer
7072 series
User Manual
7072 Series Chest Freezer
Dear customer,
This chest freezer which has successfully passed from quality control tests,
has been produced in the plant of Combisteel with a big passion.
To increase efficiency of your cooler, before using it we strongly recommend
you;
- to read the whole guide
- keep the guide as a source
- to use the cooler according to guide instructions.
We want to remind that, we will be not responsible for the damages that
depends on the incorrect usage or instruction disobedience.
For damage and information issues, please contact to nearest customer service
centre.
The product will also be out of warranty, if someone other than authorized
service interferes the product directly.
The aim of this cooler is keeping the beverages and foods cold. We will also
be not responsible if you run the product out of this purpose.
Thank you for preferring us and for your trust.
About cooler
- The operating temperature range of the chest freezer is between -1 and +4 degrees.
- The operating temperature range of the cooler is between -20/-22 degrees.
- The product does not contain Asbestos, formaldehyde, cadmium and CFC materials
- Compressor oil is based on none PCB and PCT.
- The refrigerant gas is R404a, or R290a, which is proper for KYOTO protocol.
- This device is also proper for WEEE (Waste Electric and Electronic Equipment) regulations
TECHNICAL FEATURES OF COOLER
TECHNICAL FEATURES | 7072.0005 | 7072.001 | 7072.0015 |
---|---|---|---|
GROSS VOLUME | 865 LT | 918 LT | 971 LT |
NET VOLUME | 508 LT | 561 LT | 614 LT |
INTERNAL DIMENSIONS (WXDXH) | 1744x780x590 | 1860x780x590 | 1976x780x590 |
EXTERNAL DIMENSIONS (WXDXH) | 1892x932x894 | 2008x932x894 | 2124x932x894 |
PACKAGED EXTERNAL DIMENSIONS (WXDXH) | 1999x1035x940 | 2115x1035x940 |
2231x1035x940
AREA OF PROJECTION VIEW| 1,76 m²| 1,87 m²| 1,97 m²
GROSS WEIGHT| 157,5| 164| 169
NET WEIGHT| 130| 135| 140
OPERATING TEMPERATURE| -0.2| -0.2| -0.2
PRODUCT DISPLAY AREA| 1,38 m²| 1,47 m²| 1,56 m²
TECHNICAL FEATURES OF COOLER
TECHNICAL FEATURES | 7072.002 | 7072.003 |
---|---|---|
GROSS VOLUME | 1148 LT | 842 LT |
NET VOLUME | 791 LT | 485 LT |
INTERNAL DIMENSIONS (WXDXH) | 2360x780x590 | 1860x780x537 |
EXTERNAL DIMENSIONS (WXDXH) | 2508x932x894 | 2008x932x894 |
PACKAGED EXTERNAL DIMENSIONS (WXDXH) | 2615x1035x940 | 2115x1035x940 |
AREA OF PROJECTION VIEW | 2,33 m² | 1,87 m² |
GROSS WEIGHT | 180 | 160 |
NET WEIGHT | 149 | 131 |
OPERATING TEMPERATURE | -0.2 | -0.2 |
PRODUCT DISPLAY AREA | 1,87 m² | 1,47 m² |
For commercial types, energy consumption tests are done according to the standards Technical features are specified on the labels. Combisteel reserves all the rights for changing technical features of the products, without any kind of declaration.
General appearance
Attention
The products that shown in this guide, are designed and produced according to National and International security norms. For safe and secure usage, following issues must be considered.
- Check the socket, whether it is suitable or not. A grounded socket is must.
- Make sure your structure wiring. Do not use sockets that are not fixed. Extension cable and multiple sockets are not advised. If it is an obligation, beware of voltage and cable diameter.
- If the cable is damaged, the replacement must be done by authorized Combisteel service. While running, if you have a hesitation concerning electrical connection, call the nearest service.
- When unplugging, hold the knob of the socket, never hang from cable.
- External covers must not be removed. Otherwise, dangerous parts and sections will be accessible.
- Never use pressured water. It may cause damages in electrical parts.
- A defection may come from cooler electrical system or building electrical installation. For both, do not intervene to cooler directly. Unplug the cord, call the nearest service.
- Never plug and run a damaged product (like a transport damage). Please contact to service.
- Consider the maximum loading capacity. Do not pass the loading line.
- Replacement of electrical parts must be done by nearest service.
- Keep package materials somewhere, that none-adults can reach. Package items (nylon, styrofoam etc.) may be dangerous for non-adults or children.
- For children and non-adult person usage, viewer discretion is advice.
- For interior or exterior cabinet, always use materials that producer advise to use.
- If an intervention is need, please contact to nearest service.
- Never carry or move your cooler while it is plugged. Mending or maintenance must be prevented.
- Obey the locate rules. To not to obey shutters and grids locations, may cause fires.
Instruction for carrying
- If possible, corry the cooler with a forklift or a hand lift
- If you have lift, carry the cooler with enough person in a stable position.
- While carrying the cooler always use gloves.
- While carrying the cooler just handle from wooden pallet. Never use front or protection wires.
Instruction for installation
- Remove the plastic clamps to release the cabinet from the transport pallet.
- Cut off the protection nylon on the cabinet by using a cutting tool.
- Remove the cardboard package and the styrofoam conserves on the cabinet.
- Remove the cabinet that is fixed to the pallet from the fixing areas with screwing tools.
- Unfix the fixed screws and move the cabinet on to the floor from the pallet with the help of 4 people
- Make a staple pusnina Between cooler ane wall, trere must be min 15 cm gap
- After allocated the cooler, you should wait for 4 hours Then you can plug it, the first run must be when the coolers empty for 2 hours
Assembly of cooler
- The protective film should be removed (if it exists)
- By using adjustable feet, make the cooler stable. Avoid gaps, prevent vibration.
- Compressor group air inlet must not be prevented. This is the most important issue. Allocate your product that it will be parallel to the ground, no aim is required. Adjustable feet and rollers must touch the base. The distance between compressor group and wall is important. More distance, provides increasing performance. For that reason, at least 15 cm gap is required.
- After transport of the cooler, before operating it, you should wait for three hours.
- The first running must be done when the cooler is empty. Loading can be done after this period.
- Connection of the cooler must be checked by experienced electrician. The fuse height must be 170 cm.
- For fault current, electric connection must be supported with 30 mA fuse.
- Thecooler must be also provided with the nearest ground.
Usage for the cooler
Temperature of the cooler is calibrated for the most proper conditions. The
operating temperature can be adjusted from the digital thermostat. We advise
you to keep them with default factory value. Internal temperature of the
cooler is -20 / -22 degrees, can be adjusted 01 – 04 degrees. Digital
thermostats have default factory values, and no need adjustment. Thermostats
may have many programs within (eco mode, night mode etc.) If you have a
problem with your cooler, please contact to service. Failure codes are listed
in failure section. If you get any of these, stop the alarm of the thermostat
and inform the service.
There is no a private defrost process in your cooler. Although your products
prevents snowing, high humidity and temperature may cause snowing rate.
Operating time depends on snowing, which also means energy consumption will
rise. At this position, stop the working and clean the snow.
DO NOT FORGET! UNFROZEN EVAPORATOR WILL GIVE THE HIGH EFFICIENCY.
Evaporator waters, stream to drip pan in compressor department. Although hot
gas pipe evaporates this water, checking and cleaning the pan is advised, at
least for one time in a month.
IMPORTANT!
Please do the loading by taking care of the loading line
For the 7072.0005-0010-0015-0020; The maximum loading distance is 48 cm.
Do not load above this height.
For the 7072.0030; loading should be from 5-6 cm height from the base up to 40
cm.
Before calling service & cleaning
Before calling service
FAILURE | POSSIBLE SOLUTION |
---|---|
The cooler is not working | Check the plug and fuse. |
The problem can be at electrical cable or plug.
There is snowing or sweating in the cabinet| Make sure the sliding lids are
full closed. Make sure that there is no air in the freezer.
Sweating at the glass| External humidity may be increased or there is air in
the freezer. Please control the sliding lids.
Temperature is high but it is not cooling| Control the adjustment of the
thermostat. Make sure that air panels are not be closed.
Internal cleaning
Remove beverages. Wait for the internal temperature that it will be same with
environment temperature.
For cleaning and maintenance use a protection glove, this will protect you
from injuries. Remove the accessories.
Use a soft cotton linen with warm soap water .For drying, use cotton based
linen. For first operating, wait for two hours. Than you can reload your
beverages.
External cleaning
Use a cotton base linen with warm water. Avoid water from front control panel
or lighting departments. For door gasket, just use clean water with soap.
All manuals and user guides at all-guides.com
Documents / Resources
|
Combisteel 7072 Series Chest
Freezer
[pdf] User Manual
7072 Series Chest Freezer, 7072 Series, Chest Freezer, Freezer
---|---
References
Read User Manual Online (PDF format)