SALUS RT310 Digital Room Thermostat User Manual
- June 6, 2024
- SALUS
Table of Contents
- Introduction
- Safety Information
- Technical specification
- Button functions
- LCD Icon description
- RT310 Terminals description
- RXRT510 Receiver terminals description
- DIP switches parameters
- RT310 Wiring diagram
- RT310RF Wiring diagram
- Change the Setpoint temperature
- Frost Protection
- Heat / Cool mode selection*
- Sleep Mode
- Pairing the RT310TX thermostat with the RXRT510 receiver
- Installer Mode
- Reset of the RT310 thermostat
- RT310TX thermostat reset
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Model: RT310 (Digital room thermostat)
RT310RF (Digital room wireless thermostat)
Installation Manual
Introduction
RT310 / RT310RF is a digital room thermostat used to control room temperature.
Device launching heating or cooling system by shorting terminal blocks,
simultaneously informing the action and showing this information on the LCD
display. Before use please read this manual carefully. Use only AA 1.5 V
alkaline batteries in the thermostat. Place the batteries into the battery
slot located under the cover. Do not use rechargeable batteries.
Product compliance
Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS
2011/65/EU. Full information is available on the website
www.saluslegal.com
Safety Information
Use in accordance to national and EU regulations. Use the device as intended,
keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualified
person in accordance with national and EU regulations.
Technical specification
| RT310| RT310RF
---|---|---
Thermostat supply| 2 x AA alkaline batteries| 2 x AA alkaline batteries
Receiver supply| –| 230 V AC
Thermostat rating max| 3 (1) A| –
Receiver rating max| –| 16(5)A
Outputs| Voltage free
NO / COM /NC terminals| Voltage free
NO / COM terminals
Temperature range| 5 – 35°C| 5 – 35°C
Button functions
1. Turn on the LCD backlight
2. HEAT/COOL modes change or Frost Protection mode activation
3. Increase button
4. Decrease button| 5. When in Manual Mode, ON will turn the boiler on
6. When in Manual Mode, OFF will turn the boiler of
7. Receiver operates in automatic mode according to the thermostat
8. Receiver output is controlled by the On/Off slide switch.
---|---
Receiver’s LED diode | Status | Description |
---|---|---|
Red | Solid light | Power on |
Flashing | Lost connection or pairing mode | |
Green | Solid light | System works |
LCD Icon description
1. Heating Mode ON
2. Cooling Mode ON/
Frost Protection Mode ON
3. RF signal indicator (only in RT310RF)| 4. Low battery status
5. Temperature unit
6. Room/setpoint temperature
---|---
RT310 Terminals description
Terminal | Description |
---|---|
1 – COM | Common Terminal |
2 – NC | Switched Live OFF |
3 – NO | Switched Live ON |
RXRT510 Receiver terminals description
Terminal | Description |
---|---|
NO | Switch Terminal |
COM | Common Switch Terminal |
L, N | Supply (230 V AC) |
DIP switches parameters
1 | 2 | Cooling | Heating | Default value |
---|---|---|---|---|
ON | ON | Hysteresis +/- 0.25 °C | Hysteresis +/- 0.25°C | |
ON | ON | Hysteresis +/- 1.5°C | Hysteresis +/- 0.5°C | |
ON | OFF | Hysteresis +/- 1.0°C | TPI 9 CPH | |
OFF | OFF | Hysteresis +1- 0.5°C | TM 6 CPH | NC |
RT310 Wiring diagram
RT310RF Wiring diagram
Note: If you are using the RT310RF pack, the pairing between the thermostat and the receiver is already done!
Change the Setpoint temperature
Frost Protection
The Frostpoint temperature can be reviewed by pressing the UP button once, but can only be changed in Installer Mode.
Heat / Cool mode selection*
The user can change the heating and cooling mode.
NOTE: In cooling mode, the thermostat reports a cooling demand with a
3-minute delay.
- Function available from software version v2.1
Sleep Mode
When Sleep Mode is active all the thermostat functions will be paused.
Pairing the RT310TX thermostat with the RXRT510 receiver
NOTE: IN THE RT310RF SET, THE THERMOSTAT IS FACTORY PAIRED WITH THE
RECEIVER!
If you want to pair the thermostat with the receiver again, make sure that the
device is disconnected from the power supply and the switches on the receiver
are in the AUTO and ON positions.
Installer Mode
dxx | Function | Parameter value | Default value |
---|---|---|---|
d01 | Temperature display increments | 0.1°C or 0.5°C | 0.5°C |
d02 | Temperature offset | +/-3.0°C | 0.0°C |
d03 | Frost Protection setpoint temperature | 5.0°C – 17.0°C | 5.0°C |
Reset of the RT310 thermostat
Press the RESET button (you can use a paper clip), the thermostat will reset and turn on automatically.
RT310TX thermostat reset
Remove the batteries without pressing any button. Wait 2 minutes and insert
the batteries again. Your device will be restarted.
When you want to change the batteries your device will use the internal memory
to backup your settings. You have 30 seconds to change the batteries before
losing your settings.
IMPORTER:
QL CONTROLS Sp. z o.o. Sp. k. ul. Rolna 4, 43-262 Kobielice
IMPORTER:
QL CONTROLS Sp. z o.o. Sp. k. ul. Rolna 4, 43-262 Kobielice
www.salus-controls.eu
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc
reserve the right to change specification, design and materials of products
listed in this brochure without prior notice.
References
- Choose your country – Salus
- SALUS Controls - intelligent temperature control
- salus-manuals.com
- Legal – Salus
- Domena skladnost.saluscontrols.eu jest utrzymywana na serwerach nazwa.pl
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>