ZKTeco QR600 Series QR Code Access Control Card Reader User Guide
- June 6, 2024
- ZKTECO
Table of Contents
ZKTeco QR600 Series QR Code Access Control Card Reader User Guide
QR600 Series
Due to the regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.
1. Installation
Product size 1: (length 120 (±0.5) width 80 (±0.5) height 22.67 (±1)) (mm)
1. As shown in the figure above, remove the screw and remove the backplate from the device.
2. Align the screw holes of the backplate with the holes drilled on the wall, and fix the backplate on the wall with the screws.
3. Connect the wires well, and install the device on the backplate.
4. Use the screw removed in step 1 to fix the device on the backplate.
5. Installation of device cable through the wall.
Product size 2: (length 138 (±0.5) width 58 (±0.5) height 22.67 (±1)) (mm)
1. As shown in the figure above, remove the screw and remove the backplate from the device.
2. Align the screw holes of the backplate with the holes drilled on the wall, and fix the backplate on the wall with the screws.
3. Connect the wires well, and install the device on the backplate.
2. Product Introduction
The QR600 series QR code reader is a new generation of intelligent access
control card reader
developed by our company. The product has high-end appearance, high scanning
speed, high
recognition rate, strong compatibility, and can be connected to any access
control controller
that supports Wiegand input. The reader adapts to various application
scenarios and supports
the identification of RFID radio frequency cards and QR codes, and uses non-
contact identification to replace traditional RFID cards. Dynamic QR codes can
better protect user
information security, and the product supports IP65 waterproof, which can be
applied in community management, visitor management, hotel management,
unmanned supermarkets, and other fields. The design of this series of products
is also in line with CE, FCC and other certification standards.
The features of QR600 QR code reader are as follows:
- New QR code access control technology
- ID supports EM4100/EM4200
- IC supports identification of MF, Desfire EV1, resident ID card and QR code
- Support QR code recognition : 2D : QR , Data Matrix , PDF417 ; 1D : GS1 databar, code128/Ean128, UPC/EAN, Codebar, code39/code93
- Support Wiegand34/26/32/66/RS485 switching at the same time
- Support OSDP
- Number keyboard (optional)
3. Wiring Instructions
3.1 Wiring Definition
QR600 series: 11 core wire connection mark
3.2 Device Connection
Please connect the device to other equipment according to the wiring
definition of the QR code
reader. In addition, the following only refers to the partial wiring of the QR
code reader and the
controller. It does not represent all wiring definitions of the controller.
Please refer to the actual
controller wiring definition.
Wiegand or 485 connection
1. Connect the QR code reader to the controller via Wiegand or RS485 and then
connect it the
+12V power supply. The QR code reader does not need to be connected to the
lock body
when it is used as a reader. The controller in the figure only lists some of
the wirings, and
there are many kinds of connections between the machines. Wiegand or RS485
common
connection reference as shown below:
2. Open DEMO, select the serial port number, the default baud rate is 115200,
click “Connect”
and “Scan Address” and then put the card or QR code (paper, electronic ,
mobile phone) into the recognition range of the card reader, and read the
card. The device automatically obtains and transmits the information carried
by the card or QR code to the controller.
USB connection
- First, connect the QR code reader to the PC terminal t 1. hrough the USB cable.
- Open DEMO, select USB for the serial port number, click “Connect” and “Scan Address”, it prompts that the connection is successful, and then place a card or QR code (paper,
electronic, mobile phone) within the reader’s recognition range, the card reader will automatically obtain and transmit the information carried by the card or QR code to the
controller.
4. Set up the QR Cord Reader with Demo Software
This section describes how to configure the QR code reader through the DEMO software.
4.1 Configuration
- Connect the QR code reader to the computer with a USB cable, open the Demo software,
select the USB port, and click “OK”. (Note: If a serial connection is selected, the baud rate is 115200 by default).
Note:
- Support to connect the configuration tool through USB and serial port.
- USB: Connect to the configuration tool by means of USB communication; COM: Connect to the configuration tool by means of 485 communication.
- The version number in the screenshot only represents the version number of the test sample, please refer to the version number of the actual product.
2. When the connection is successful, in the Download Configuration area below, click “Download”.
3. When it prompted “Download con guration is complete!”, you can complete the QR code reader configuration in one click, easy to operate.
4.2 Device Operation
Operation Steps:
1. If the user needs to set the parameters of the QR code reader by
themselves, open the Demo
software, after successful connection, enter the advanced settings page in the
top right corner of the page.
2. Enter advanced settings page.
3. On the “Reader Operation” page, set the configuration parameters of the
card reader as
required.
- Click “Search Device” to view the communication address of the card reader.
Note: If you select the RS485 address, you can click “Search Device” to
get the correct device
address before you can perform other operations.
2. Click “ Get Version ” to view the version number information of the card reader.
3. Set the relevant parameters of the card reader.
4.3 Function Selection
Operation Steps:
- On the “Function Selection” page, click “Read Configuration” to view the configuration information of the current card reader.
- Users can also set the parameter information of the reader by themselves, and then click “Write Configuration” to configure the parameter information of the QR code reader
3. Support for restoring the card reader to its factory settings.
4.4 Wiegand and QR Parameter Settings
Operation Steps:
- On the “Wiegand Setting” page, set the parameters for Wiegand.
2. On the “ QR Code Parameter setting ” page.
After setting the parameters, click “ Write QR code parameter settings ”
to write the information into the card reader. Click “ Read QR code
parameter settings ” to display the
configuration information of the card reader.
4.5 Reader Parameter Setting
Operation Steps:
1. On the “Read Card Setting” page, set the reading parameters of the card reader.
2. Once you have set the parameters, click “ Write Configuration ” to write the information to the card reader.
3. Click “ Read Configuration ” to display the configuration information of the card reader.
4.6 Import and Export Configuration
Operation Steps:
On the “Page Configuration” page, click “Export Configuration” to exporting
the page configuration information of the current device, click the “Import
Configuration” to importing configuration information.
Note:
This function is used by before and after reset. After the reset, the function
parameters will be
restored to the default values, and need to be reload the setting parameters
to read PDF417 and
QR code. Therefore, it needs to be configured according to section 4.2.Before
reset, you need to
back up .json. Otherwise, please do not restore factory settings.
-
The imported and exported configuration files can only be cfg.json files.
-
The exported configuration file can be used for one-key configuration. When entering the
advanced settings page, the configuration information will also be loaded according to the
cfg.json configuration file. -
If there is no cfg.json configuration file in the .exe directory, when you enter the advanced
settings page, the background will generate a cfg.json file by default.
4.7 Firmware Upgrade
Operation Steps:
On the “ Firmware Upgrade ” page, click “ Open File “, select the upgrade program, click “Start” button, plug in the USB and reconnect the computer to the computer to view the prompt message, indicating that the upgrade is successful.
ZKTeco Industrial Park, No. 32, Industrial Road,
Tangxia Town, Dongguan, China.
Phone : +86 769 – 82109991
Fax : +86 755 – 89602394
www.zkteco.com
This Device is designed as a Driving Aid, this will not replace the Driver’s responsibility to pay attention to the road ahead in order to make safe and informed decisions.
Read More About This Manual & Download PDF: