Overview

Thermal Imaging Temperature Detection Module Flash Near-infrared Flash Camera & Palm Collector Microphone 4-inch Touchscreen
Doorbell Button
Card Reading Area

Speaker Reset

USB

12V GND

Power In

TX+

TXRX+

Ethernet

RX-

Lock
RS485 WiegandIn

Alarm

AL+ ALNO GND COM AUX NC BUT GND SEN 485B BELL+ 485A BELLIWD0 GND IWD1 GND +12V WD0 GND WD1

Auxiliary Input Exit Button Sensor Bell
Wiegand Out

Note: Not all products have the function with , the real product shall prevail.
1

Installation Environment
Please refer to the following recommendations for installation.

INSTALL INDOORS ONLY

AVOID INSTALLATION NEAR
GLASS WINDOWS

AVOID DIRECT SUNLIGHT
AND EXPOSURE

Recommended Palm Gestures

3

AVOID USE OF ANY HEAT SOURCE
NEAR THE DEVICE

KEEP EFFECTIVE DISTANCE OF 30-50 cm

KEEP SPACES BETWEEN
YOUR FINGERS

DO NOT KEEP YOUR FINGERS
CLOSE

DO NOT KEEP PALM OUTSIDE COLLECTION AREA

DO NOT KEEP YOUR FINGERS FOLD/CURLED

Note: 1. Place your palm within 30-50 cm of the device. 2. Place your palm in the palm collection area, such that the palm is placed parallel
to the device. 3. Make sure to keep space between your fingers.

Recommended Standing Position

KEEP EFFECTIVE DISTANCE OF 0.3m-2m
2

Installation Requirements

The installation requirements and indications associated with the device are given below:

Specification

Standard value

Remark

Operating Environment

Indoor, Avoid wind, Avoid direct sunlight,
16°C to 35°C (60.8°F to 95°F)

The recommended operating temperature is 25°C (77°F)

Distance (between face 30cm to 120cm (0.98ft to 3.94ft)

The recommended distance is 80cm (2.62ft)

and device)

Measurement Accuracy

±0.3°C (±0.54°F)

This value is tested at a distance of 80cm or 2.63ft under 25°C (77°F) environment.

Note: The temperature measurement data is only for reference, and not for any medical purposes.

Forehead Temperature Detection Indoor constant Temperature Environment

Installation height: 1.55m
FOV (Field Of View) of the thermal imaging device: 50°
Temperature detection distance: 0.3m to 1.2m
Height of the face adapted for detection: 1.2m to 2m
155CM

3

Standalone Installation
Alarm
Door Sensor

Card

Lock

Reader

SDmetoekcetor

Exit Button

TCP/IP

ZKBioAccess IVS

Power Connection

12V GND

12V DC GND

Recommended A Adapter

  1. 12V ± 10%, at least 3000mA. 2) To share the power with other devices, use an A Adapter with higher current
    ratings.
    4

Ethernet Connection

TX+ TXRX+ RX-

1

2

3

4 5

RJ

45

6

7

8

Default IP address: 192.168.1.201 Subnet mask: 255.255.255.0

ZKBioAccess IVS
IP address: 192.168.1.130 Subnet mask: 255.255.255.0

Click [COMM.] > [Ethernet] > [IP Address] , input the IP address and click [OK]. Note: In LAN, IP addresses of the server (PC) and the device must be in the same network segment when connecting to ZKBioAccess IVS software.
Door Sensor, Exit Button & Alarm Connection

Alarm’s Power Alarm Switch

AL+ ALNO GND NO COM AUX COM

SDmetoekcetor

NC BUT

GND SEN

485B BELL+ Door 485A BELL- Sensor

IWD0 GND

IWD1 GND

ExitButton

5

Lock Relay Connection

The system supports both Normally Opened Lock and Normally Closed Lock. The NO Lock (normally opened when powered) is connected with ‘NO1’ and ‘COM’ terminals, and the NC Lock (normally closed when powered) is connected with ‘NC1’ and ‘COM’ terminals. The power can be shared with the lock or can be used separately for the lock, as shown in the example with NC Lock below:

  1. Device not sharing power with the lock

DC12V DC12V
FR107
Normally Closed Lock

+12V GND
AL+ NO COM NC GND 485B 485A IWD0 IWD1 +12V GND

  1. Device sharing power with the lock DC12V
    FR107
    Normally Closed Lock

+12V GND
AL+ NO COM NC GND 485B 485A IWD0 IWD1 +12V GND

6

Wiegand Reader Connection
Wiegand card reader connects to the top 4 pins of the wiegand terminal and the last two pins are used by the Access Controller, as shown in the following figure. It sends the credentials to the device via wiegand communication.

WD0 WD1

Access Controller

IWD0 IWD1 +12V GND

WD0 WD1 +12V GND
Wiegand Reader

RS485 Connection
The RS485 lets user connect to multiple readers to the device. RS485 can be connected to the terminal, as shown in the figure below.

AL+ NO COM NC GND 485B 485A IWD0 IWD1

GND 485485+
RS485 Reader

7

User Registration
When there is no super administrator set in the device, click on to enter the menu. Add a new user and set User Role to Super Admin, then the system will request for the administrator’s verification before entering the menu. It is recommended to register a super administrator initially for security purposes.
Method 1: Register on the device Click on > [User Mgt.] > [New User] to register a new user. The options include entering the User ID and Name, setting User Role, registering Palm, Face, Card Number, Password and adding Profile Photo.

2021-04-29 14:31

Main Menu

L User Mgt. User Role

COMM.

System

Personalize Data Mgt.

Access Control

USB Manager

New User

User Mgt.

All Users

Display Style

2021-04-29 Thursday Welcome

Attendance Search

Autotest

System Info

L

User ID

New User

Name

User Role

Palm

Face

Card Number

Password

Profile Photo

Access Control Role

1 Mike Normal User
1 1 1 ***** 1

Palm Registration
Enrolled Successfully
8

Enroll Face Enrolled Successfully

Method 2: Register on ZKBioAccess IVS software
Please set the IP address and cloud service server address in the Comm. Menu option on the device. 1. Click [Access] > [Access Device] > [Device] > [Search] to search the device on the
software. When an appropriate server address and port is set on the device, the searched devices are displayed automatically.

Refresh

New

Delete

Export

Search

Control

Set up

Search

Step 1
No device found? Download Search Tools to Local Disk

Search Device

Total Progress IP Address

Step 2

Device Type

Searched devices count:1 Serial Number

IP Address 192.168.213.79

MAC Address

Subnet Mask 255.255.255.0

Gateway Address 192.168.213.1

Serial Number Device Type

View / Get Set Server

Communication
Step 3 Operations
Add

Add

Device Name
Icon Type
Area The current systen communication port is 6609, please make sure the device is set correctly.
Add to Level Clear Data in the Device whenClAosdeding

192.168.213.79 Door Area Name

[Clear Data in the Device when Adding] will delete data in the device(except event record), please use with caution!

Step 4

OK

Cancel

2. Click [Add] in operation column, a new window will pop-up. Select Icon type, Area, and Add to Level from each dropdowns and click [OK] to add the device.
3. Click [Personnel] > [Person] > [New] and fill in all the required fields to register a new users in the software.
4. Click [Access] > [Device] > [Control] > [Synchronize All Data to Devices] to synchronize all the data to the device including the new users.
For more details, please refer to the ZKBioAccess IVS User Manual.
Note: If the device has optional dynamic QR code function, you need to use the ZKBioSecurity to connect the device and perform the corresponding operation to support the QR code function.
9

Method 3: Register on the phone
Once the ZKBioAccess IVS software is installed, the users could enroll their face via a browser application on their own mobile phone.
1. Click [Personnel] > [Parameters], input’http://Server address: Port”in the QR Code UGL bar. The software will automatically generate a QR code. Scan the QR code or login ontohttp://Server address: Port/app/v1/adreg” by the mobile phone to register users.

Personnel Registration
Personnel Registration
Personnel ID 4835 First Name Mike Last Name Last Name

Personnel
Person Department Pending Review Custom Attributes Parameters

Personnel ID Setting

The Maximum Length:

9

Support Letters:

Yes

No

Personnel ID Auto-increment: Yes

No

Card Setting

The Maximum Length: 32

Bits(Binary)

Card Format Display: Decimal

Hexadecimal

Pending Personnel Setting Enable Auto-audit:

Yes

No

Self-service Registration QR Code URL: http://Server address:Port Download QR code image

OK

Card Management

OK

2. The users will be displayed in [Personnel] > [Pending Review], click on [Review] option and assign a department and click [OK] to successfully add the user.

Personnel
Person Department Pending Review Custom Attributes Parameters

Personnel ID

The current query conditions None

Refresh

Review

Delete

Name

Personnel ID First Name

Last Name

4835

Mike

Mobile Phone

Welcome, admin

Status

Create Time

Operations

Delete

Card Management

1-1

50 rows per page

Jump To 1

/0 Page Total of 0 records

10

Ethernet and Cloud Server Settings
Click on > [COMM.] > [Ethernet] to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the upper right corner of the standby interface.
Click on > [COMM.] > [Cloud Server Setting] to set the server address and server port, that is, the IP address and port number of the server after the software is installed. If the device communicates with the server successfully, the icon will be displayed in the upper right corner of the standby interface.

Main Menu

User Mgt. User Role

L COMM.

System

Personalize Data Mgt.

Access Control

USB Manager

Attendance Search

Autotest

System Info

IP Address

Ethernet

Subnet Mask

Gateway

DNS

TCP COMM. Port

DHCP

Display in Status Bar

192.168.163.200 255.255.255.0 192.168.163.1 0.0.0.0 4370

Cloud Server Setting Server Mode

ADMS

Enable Domain Name

Server Address

110.80.38.74

Server Port

8881

Enable Proxy Server HTTPS

Note: While pairing the device with ZKBioAccess IVS software. Make sure that the option Enable Domain Name is disabled and the correct server address and port are entered. Server Address: Set as the IP address of the ZKBioAccess IVS server. Server Port: Set as the service port of ZKBioAccess IVS (the default is 8881).

11

Access Control Setting
Click on > [Access Control] to enter the access control management interface and set relevant parameters of access control.

Main Menu

User Mgt. User Role

COMM.

System

Personalize Data Mgt.

L Access
Control

USB Manager

Attendance Search

Autotest

System Info

Access Control Access Control Options Time Rule setting Holidays Combined Verification Anti-passback Setup Duress Options

Access Control Options Gate Control Mode

Verification Mode

Password/Face/Palm

Door available time period

1

Normal open time period

None

Master Device

In

Slave Device

Out

Auxiliary input configuration Verify mode by RS485

Card Only

Speaker Alarm Reset Access Setting

Attendance Record

Click on > [Attendance Search] > [Event Logs] to enter the logs query interface, input the user ID and select the time range, the corresponding event logs will be displayed.

Main Menu

User Mgt. User Role

COMM.

System

Personalize Data Mgt.

Access Control

USB Manager

L Attendance Search

Autotest

System Info

Attendance Search Event Logs Attendance Photo Blocklist ATT Photo

Personal Record Search

Date 03-03
03-04
03-05

User ID
4 2 3
1 3 2 4
1 4 3 2

Time Number of Records:04 11:25 11:25 11:22 11:25 Number of Records:04 11:29 11:29 11:21 11:28 11:26
Number of Records:04
11:27 11:27 11:27 11:27

12

Detection Management Settings
Click on > [System] > [Detection Management] to enter the setting interface.
You can set the value of High temperature alarm threshold, and enable the Temperature over the range; access denied and the Trigger external alarm, the device will send an alarm prompt when the temperature of the user detected exceeds the set value, meanwhile the user will be forbidden to access, as shown in the following figure. The method of enabling Mask detection is also the same.
When Allow unregistered people to access is enabled, optionally, set Enable capture of unregistered person to save the temperature data.

Main Menu

User Mgt. User Role

COMM.

L System

Personalize Data Mgt.

Access Control

USB Manager

Attendance Search

Autotest

System Info

Detection Management Display Thermodynamics Figure Display Body Temperature Enable mask detection Deny access without mask Allow unregistered people to access Enable capture of unregistered person Trigger external alarm Clear external alarm Exter alarm delay(s) Update Firmware

Date Time Access Logs Setting Face Palm Parameter Video intercom parameter Reset USB Upgrade Device Type Setting Detection Management
08:50
Normal temperature Temp.: 36.6OC

Detection Management Enable temp. screening with infrared

High temperature alarm threshold

37.30 OC

Temp. over the range; access denied

Temperature deviation correction

0.00

Temp. Unit

OC

Temperature measurement distance

Far

Display Thermodynamics Figure

Display Body Temperature

Enable mask detection

Deny access without mask

08:50

High body temperature Temp.: 38.6OC

Mask Detected
Successfully verified.
Name:Mike User ID:1 Verify:Face

Without mask
Failed to verify.
Verify:Face User ID:1

13

Note: 1. The effective distance for temperature detection is within 30-50cm for the palm
and 0.3-2m for the face. 2. Recommended for indoor use only. 3. Temperature measurement data is only for reference, and not for medical use. 4. Remove the mask to register the face, and wear the mask while recognizing the
face.The type of mask, the size of the face covered by the mask, and bangs will affect the facial recognition process. 5. Facial verification for masked individuals will increase FAR. Palm verification for masked individuals is recommended.
Effective distance
Effective distance: Temperature: 30cm-120cm Palm: 30cm-50cm Face: 0.3m-2m
Real-time monitoring on the ZKBioAccess IVS software
Once ZKBioAccess IVS software installed, users could perform temperature detection management on browser. 1. Set the IP address and cloud service server address on the device and add the
device to the software. 2. Click [Temperature Detection] > [Temperature Management] > [Real-time
Monitoring] to view all the events include the Abnormal Temperature, No Masks and Normal Records. 3. Click [Temperature Management] > [Statistics Panel] to view the analysis of statistical data and view the personnel with normal temperature.
14

As shown in the following figure.

Real-Time Monitoring

Temperature Management
Real-Time Monitoring Statistics Panel Temperature Raw Record

2020-05-22 11:03:07 Abnormal Temperature

Abnormal Temperature Record Department Daily Statistics Monthly Statistics Automatic Report Parameters

52.1oC

Mask:

None

Name:

(19961107)

Department: null

Time:

09:50:48

No Masks

Real-Time Monitoring

0 Total:

0

0

0

None

None

None

None

Temperature: 36.65°C

Temperature: 36.65°C

Temperature: 36.65°C

Temperature: 36.65°C

Name:

UnregisterUser Name:

UnregisterUser Name:

UnregisterUser Name:

UnregisterUser

Department: NULL

Department: NULL

Department: NULL

Department: NULL

Time:

14:42:00

Time:

14:42:00

Time:

14:42:00

Time:

14:42:00

Welcome, admin

Normal Records

Name:

UnregisterUser

Department: NULL Temperature: 36.57°C

Mask:

Yes

Time:

15:01:39

Name:

UnregisterUser

Department: NULL Temperature: 36.57°C

Mask:

Yes

Time:

15:01:39

Name:

UnregisterUser

Department: NULL

Temperature: 36.57°C

Mask:

Yes

Time:

15:01:39

Statistics Panel

Temperature Management Real-Time Monitoring Statistics Panel Temperature Raw Record

Statistics Time Today
The current query conditions None Refresh

Abnormal Temperature Record

Department Daily Statistics Monthly Statistics

Unmeasured body temperature

Automatic Report

Parameters

Welcome, admin

ViewNormal temperaturePeople Personnel ID
The current query conditions None Refresh

Personnel ID

First Name

3 2

Department Name

Department Number
1
1

Department Name
Sales Sales

Temperature abnormal

Normal temperature

Temperature abnormal

Unmeaured body temperature

1-2

50 rows per page

Jump To 1

/1 Page

For more details, please refer to the ZKBioAccess IVS User Manual.

15

QR Code as the Mobile Credential
1. 2. On the server, choose [System] > [Authority Management] > [Client Register] to add a registered App client. 3. Open the APP, enter the IP address or domain name of the server, and its port
number, scan the Register QR-code. After the connection is successful, tap on Employee to switch to the Employee Login screen. Enter the Employee ID and Password (Default: 123456) to login. 4. Tap [Mobile Credential] on the APP, and a QR code will appear. Place the phone screen right in front of the device QR code scanner. For details, please refer to the 4-inch Thermal Imaging Product User Manual.
Note: 1. Place your phone within 15-50cm of the device (distance depends on the size of
the phone screen and the density of the QR code). Do not block the camera and the QR code. 2. For more details of Dynamic QR Code, please refer the ZKBioSecurity Mobile APP User Manual.
16

ZKTeco Industrial Park, No. 32, Industrial Road,

Tangxia Town, Dongguan, China.

Phone : +86 769 – 82109991

Fax

: +86 755 – 89602394

www.zkteco.com

Copyright 2021 ZKTECO CO., LTD. All Rights Reserved.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals