ZKTeco Elite Series [TI] Instruction Manual

October 27, 2023
ZKTECO

ZKTeco Elite Series [TI] Instruction Manual

Overview

Overview`
Overview

Installation Requirements

The installation requirements and indicators associated with the temperature detection is given below:

Specifica Standard value Remark
Operating Environment Indoor, No wind, No direct light, 20°C to 35°C (68°F to

95°F)

| The recommended operating temperature is 25°C (77
Distance (between face and device)| 30cm to 120cm (0.98ft to 3.94ft)| The recommended distance is 80cm (2.62ft)
Measurement Accuracy| Measurement Accuracy| This value is tested at a distance of 80cm or 2.63ft under 25°C or 77°F environment.

Forehead Temperature Detection

Forehead Temperature

Indoor constant Temperature Environment

  • Installation height: 1.55m
  • FOV (eld of view) of the thermal imaging device: 50°
  • Temperature measurement distance: 0.3m to 1.2m
  • Height of the face adapted for detection: 1.2m to 2m

Installation Environment:

  • INSTALL INDOORS ONLY

  • AVOID INSTALLATION NEAR GLASS WINDOWS

  • AVOID DIRECT SUNLIGHT AND EXPOSURE

  • AVOID USE OF ANY HEAT SOURCE NEAR THE DEVICE

Device Installation

Installation on the wall

  1. Attach the mounting template sticker to the wall, and drill holes according to the mounting paper.

  2. Fix the back plate on the wall using the wall mounting screws.

  3. Attach the device to the back plate.
    Installation

  4. Fasten the device to the back plate with a security screw.
    Installation

Device Installation

Installation on the barrier gate

  1. Drill a hole on the barrier gate, insert the bracket into the hole and fix it with a nut.
    Installation

  2. Adjust the angle of the device.

Standalone Installation

Installation

Door Sensor, Exit Button & Alarm Connection

Connection

Lock Relay Connection

The system supports both Normally Opened Lock and Normally Closed Lock. The NO Lock (Normally Opened when powered) is connected with ‘NO’ and ‘COM’ terminals, and the NC Lock (Normally Closed when powered) is connected with ‘NC’ and ‘COM’ terminals. The power can be shared with the lock or can be used separately for the lock, as shown in the example with NC Lock below:
Connection
Connection

Wiegand Reader Connection

Connection
Connection

Barrier Connection

Connection

RS485 Connection

Connection

Printer Connection

Connection

Power Connection

Connection

  • Recommended power supply: 12V – 3A
  • To share the power with other devices, use a power supply with higher current ratings

Ethernet Connection

Connection

Connect the device and the system software over an Ethernet cable. An example is shown below:

Note: In LAN, IP addresses of the server (PC) and the device must be in the same network segment when connecting to the ZKBioSecurity MTD software.

Click [Comm.] > [Ethernet] > [IP Address], enter the IP address and click[OK].

User Registration

When there is no Super Administrator set in the device, click to enter the menu. Add a new user and set the User Role to Super Admin, then the system will request for Administrator’s verication before entering the menu. It is recommended to register a Super Administrator initially for security purposes.
Registration
Registration

Method1: Registration on device

Click> [User Mgt.] > [New User] to register a new user. The procedure includes entering the User ID and Name, registering Face, Password and User Photo, setting the User Role and Access Control Role.

Method 2: Registration on ZKBioSecurity MTD software

Please set the IP Address and Cloud Service Server Address in the Comm. Menu on the device.

  1. Click [Access] > [Access Device] > [Device] > [Search Device] to search the device on the software. When an appropriate server address and port is  set on the device, the searched devices will be displayed automatically
    Registration

  2. Click [Add] in the operation column, a new window will pop-up. Select  the Icon type, Area, and Add to   Level from each drop-down and click [OK] to add the device.

  3. Click [Personnel] > [Person] > [New] and fill all the required fields to register a new user in the software.

  4. Click [Access] > [Device] > [Device Control] > [Synchronize All Data to Devices] to synchronize all the data to the device including the new users.

For more details, please refer the ZKBioSecurity MTDUser Manual.

Method 3: Register on Phone

Once the ZKBioSecurity MTD software is installed, the users could enroll their face via a browser application on their own mobile phone

  1. Click [Personnel] > [Parameters], enter‘’http://Server address:Port’’in the QR Code UGL bar. The software will automatically generate a QR code. Scan the QR code or login onto ‘’http://Server address: Port/app /v1/adreg’’by the mobile phone to register users.
    Registration

  2. The users will be displayed in [Personnel] > [Temporary Personnel], click [Review] option and assign a department and click [OK] to successfully add the user.
    Registration

Ethernet and Cloud Server Settings

Click > [Comm.] > [Ethernet] to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the top right corner of the standby interface.

Click > [Comm.] > [Cloud Server Setting] to set the server address and server port, that is, the IP address and port number of the server after the software is installed. If the device communicates with the server successfully, the icon will be displayed in the top right corner of the standby interface.
Registration

Note

While connecting the device with the ZKBioSecurity MTD software, make sure that the option Enable

Domain Name is disabled and the correct server address and port are entered.

Server address: Set as the IP address of the ZKBioSecurity MTD server.

Server port: Set as the service port of ZKBioSecurity MTD (the default is 8088).

Access Control Setting

Click > [Access Control] to open the access control management interface and set the relevant parameters of access control.
Registration

Attendance Record

Click > [Attendance Search] > [Attendance Record] to open the records query interface, enter the User ID and select the time range, the corresponding attendance logs will be displayed.
Registration

Detection Management Settings

Click > [System] > [Detection Management] to open the settings interface.

  1. You can set the value of High temperature alarm threshold, and enable the Temperature over the range; access denied and the Trigger external alarm, the device will send an alarm prompt when the temperature of the user detected exceeds the set value, and the user will be forbidden to access. You can also enable Mask detectionthe same.
  2. When the Allow unregistered people to access is enabled, you can also set Enable capture of unregistered personto save the temperature data.
    Registration
    Registration`

Precautions

  1. The effective distance for temperature and face detection is within 0.3m to 1.2m and 0.3m to 2.5m respectively.
  2. It is recommended for indoor use only.
  3. The temperature detection data is for reference only, and not for medical use.
  4. Remove the mask while registering the face, and wear the mask while recognizing the face. The type of mask and the size of the face covered by the mask will affect the facial recognition process.

Registration

Real-time monitoring on ZKBioSecurity MTD software

Once the ZKBioSecurity MTD software is installed, users can perform several monitoring operations:

  1. Please set the IP address and cloud service server address on the device and add the device to the  software.
  2. Click [Temperature Detection] > [Temperature Management] > [Real time monitoring] to view all the Abnormal Temperature, No Masks, and Normal Records. The user data of abnormal body temperature is displayed on the Abnormal Temperature information bar automatically according to the Temperature Threshold Setting.
  3. Click [Temperature Management] > [Statistics Panel] to view the analysis of statistical data in the form of a pie-chart of personnel data with normal temperature, abnormal temperature, and unmeasured body temperature. Also, the detailed information of the personnel can be seen on the right side by clicking on the particular category on the pie-chart.

Real-Time Monitoring
Registration

Statistics Panel
Registration

For more details, please refer the ZKBioSecurity MTD User Manual.

ZKTeco Industrial Park, No. 26, 188 Industrial Road, Tangxia Town, Dongguan, China.

Phone : +86 769 – 82109991

Fax : +86 755 – 89602394

www.zkteco.com
QR code

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals