Thermostat RT520
RT520 THERMOSTAT – FULL USER MANUAL
TABLE OF CONTENTS
1. Introduction……………………………………………………………………………………………………………………………………………4 1.1
Product Compliance ………………………………………………………………………………………………………………………………………………….4
1.2 Safety
Informations…………………………………………………………………………………………………………………………………………………..4
2. Product Overview …………………………………………………………………………………………………………………………………….5 2.1
Example of boilers compatible with the OpenTherm OT+ 4.0
protocol………………………………………………………………………………6 2.2
Montage………………………………………………………………………………………………………………………………………………………………….7 2.3
Package content……………………………………………………………………………………………………………………………………………………….7 2.4
Proper thermostat location
………………………………………………………………………………………………………………………………………..7 2.5 Connection
description………………………………………………………………………………………………………………………………………………8 I A –
Boiler connection ……………………………………………………………………………………………………………………………………….8 I B –
Pump / Valve connection……………………………………………………………………………………………………………………………..8 I C
– KL08NSB underfloor heating wiring center connection
…………………………………………………………………………………….8
3. Before you start (first power up)
………………………………………………………………………………………………………………….9 3.1 LCD icon description
………………………………………………………………………………………………………………………………………………….9 3.2 Button
description…………………………………………………………………………………………………………………………………………………….9 3.3
First power up sequence and
configuration…………………………………………………………………………………………………………………10 3.4 OpenTherm – Hot
Water configuration………………………………………………………………………………………………………………………..14
4. User settings …………………………………………………………………………………………………………………………………………15 4.1
Manual mode …………………………………………………………………………………………………………………………………………………………15 4.2
Schedule mode – programming
schedule……………………………………………………………………………………………………………………16 4.3 Switching between
manual and schedule mode ………………………………………………………………………………………………………….17 4.4 BOOST
mode – hourly temperature override
(+Hr)……………………………………………………………………………………………………….18 4.5 Control and Heat/Cool
settings………………………………………………………………………………………………………………………………….19 4.6 Landlord
settings ……………………………………………………………………………………………………………………………………………………20 4.7
Time/Date ……………………………………………………………………………………………………………………………………………………………..22 4.8
Holiday mode …………………………………………………………………………………………………………………………………………………………23 4.9
Language ………………………………………………………………………………………………………………………………………………………………24
5. Factory Reset…………………………………………………………………………………………………………………………………………25
6. Error codes ……………………………………………………………………………………………………………………………………………25
7. Battery change ………………………………………………………………………………………………………………………………………25
8. Cleaning and Maintenance ……………………………………………………………………………………………………………………….26
9. Technical Informations…………………………………………………………………………………………………………………………….26
10. Warranty …………………………………………………………………………………………………………………………………………….27
1. Introduction
1.1 Product Compliance
This product complies with the essential requirements and other relevant
provisions of Directives 2014/53/EU and 2011/65/EU. The full text of the EU
Declaration of Conformity is available at the following internet address:
www.saluslegal.com.
1.2 Safety Informations
· Before starting installation work and before using the product, read the
entire manual. · The information contained in the instructions is essential
for proper functioning. · To avoid accidents resulting in personal injury and
material damage, please follow all safety precautions, specified in this
manual. · The device should not be used by people with limited mental, sensory
or mental abilities, without experience, of insufficient knowledge as well as
children. · Do not use an unassembled device (eg without a cover). · The
device may only be opened by a qualified person. · Keep electrical devices out
of the reach of children and ensure that they do not play with it. Children
should not be left unattended. If necessary, disconnect the control system for
the entire room. · Do not leave the packaging, cabinet, or any loose parts of
the device unattended, as they pose a risk to children. WARNING! ·
Installation must be carried out by a qualified person with appropriate
electrical qualifications in accordance with standards and regulations in
force in the given country and in the EU. · Never try to connect the device
other than as described in the manual. · Before assembly, repair or
maintenance as well as during any connection works it is absolutely necessary
disconnect the mains supply and make sure that the terminals and electric
wires are not live. · The device may not be exposed to extreme temperatures,
strong vibrations or subjected to mechanical shock. · The device should not be
used in unfavorable environmental conditions or in rooms where there is a
concentration of flammable gases, fumes or dust. WARNING! · There may be
additional protection requirements for the entire installation that the
installer is responsible for maintaining.
Care for the natural environment is of paramount importance to us. The
awareness that we manufacture electronic devices obliges us to dispose of used
electronic components and devices safely. Therefore the company has received a
registration number issued by the Chief Inspector for Environmental
Protection. The crossed out symbol the trash can on the product means that the
product must not be disposed of with ordinary waste containers. Sorting waste
for recycling helps to protect the environment. It is the user’s
responsibility to surrender used equipment to a designated collection point
for recycling waste from electrical and electronic equipment.
4
2. Product Overview
The RT520 room thermostat simply switches the heating system on and off as
necessary. It works by sensing the air temperature, switching on the heating
when the air temperature falls below the thermostat setting, and switching it
off once this set temperature has been reached.
Turning a room thermostat to a higher setting will not make the room heat up
any faster. How quickly the room heats up depends on the design of the heating
system, for example, the size of boiler and radiators. Neither does the
setting affect how quickly the room cools down. Turning a room thermostat to a
lower setting will result in the room being controlled at a lower temperature,
and saves energy.
The heating system will not work if a time switch or programmer has switched
it off.
The way to set and use your room thermostat is to find the lowest temperature
setting that you are comfortable with, and then leave it alone to do its job.
The best way to do this is to set the room thermostat to a low temperature
say 18C and then turn it up by one degree each day until you are comfortable
with the temperature.
You won’t have to adjust the thermostat further. Any adjustment above this
setting will waste energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only
one room thermostat to control the whole house. But you can have different
temperatures in individual rooms by installing thermostatic radiator valves
(TRVs) on individual radiators. If you don’t have TRVs, you should choose a
temperature that is reasonable for the whole house. If you do have TRVs, you
can choose a slightly higher setting to make sure that even the coldest room
is comfortable, then prevent any overheating in other rooms by adjusting the
TRVs.
Room thermostats need a free flow of air to sense the temperature, so they
must not be covered by curtains or blocked by furniture. Nearby electric
fires, televisions, wall or table lamps may prevent the thermostat from
working properly.
Thermostat is compatibile with OpenTherm OT+ 4.0 version. The OpenTherm
protocol is an open standard communication protocol used in central heating
systems for two-way communication between a central heating boiler and a room
thermostat. Thanks to the communication protocol, the boiler power is
modulated, which can significantly increase the energy efficiency of the
heating system while maintaining the set temperature in the room. OpenTherm
modulation, compared to standard communication (ON / OFF), occurs by setting
the desired temperature of water from the boiler (boiler power), and not by
its cyclical switching on and off.
PLEASE NOTE!
Make sure your gas combi boiler is compatible with OT + 4.0 communication
protocol. The list of compatible boilers is on the next page.
Product advantages:
·
automatically detects OT + 4.0 protocol and regulates hot water temperature
·
possibility to choose Hysteresis or built-in TPI algorithm for all types of heating
·
works with time schedules
·
service mode protected by a PIN code
·
maximum / minimum temperature limitation
·
can temporarily change the temperature (overwriting until the next program change)
5
2.1 Example of boilers compatible with the OpenTherm OT+ 4.0 protocol
COMPANY
MODEL
E-Tec S E-tec Plus Alpha Heating E-tec Evoke Intec GS
iC Atag iC Economiser
iS
100 Combi
Baxi
200 Combi 400 Combi
600 Combi
D2CND 24Kw Daikin D2CND 28kw
D2CND 35kw
Ferroli
i25 Condensing Combination Boiler i29 Condensing Combination Boiler
Independent + Combi
Independent Combi
Independent System
Logic Combi+ Combi C
Ideal
Logic Combi C24, C30, C35 (via a separate bundle set) Logic Code Combi (via a separate bundle set)
I-mini C24, c30 (via a separate bundle set)
Vogue Combi C26,C32, C40
Logic + System
Logic + Heat
Intergas
Intergas Rapid Intergas Rapid Plus Combi Compact, Compact Range ECO RF Xtreme Xclusive
Main Eco Compact Combi 25-30
Navien Navien NCB
Ravenheat
Avanta, Quinta Ace Quinta Pro Gas 110 Eco
Vokera
Evolve C Evolve S Linea One (przez OpenTherm Kit Part_1221179) Vision Combi (requires a control interface 294501430 Compact A (requires a control interface 29450143) Verve (only heating mode) Mynute I (only heating mode) Vision System (only heating mode) Unica I Vibe Vision C
COMPANY
MODEL
Vokera
Linea HE Mynute A Mynute HE Unica HE
Viessmann
Vitodens 100W Typ WB1A (Connection: X3.3 and X3.4) Vitodens 100W Typ WB1B (Connection: X21.1 and X21.2) Vitodens 100WTypWB1C (Connection: X21.1 and X21.2) Vitodens 200-W WB2B 26+ 35 kW (via Expansion Module OT and OT-A8 + _Terminal -10 and +10 are on the extension of the A8 boiler) Vitodens 200-W WB2C, B2HA,B2JA, B2LA (via icm Expander OpenTherm)
Vaillant (via Vaillant VR33 module)
Ecotec Pro Ecotec Plus Ecotec Exclusive Ecofit Pure
Worcester Bosch (via Nefit EMS-OT
OpenTherm converter)
EMS capable boilers Greenstar i Greenstar i Junior (Made in July 2013) Greenstar Si Compact Greenstar CDi Compact Greenstar CDi Classic (Made after 16.01.2007 with CF12.10 software version and newer) Greenstar Highflow CDi Greenstar 12i System 24i System (On condition that an optional integrated diverter valve manufactured after February 2011 is installed) Greenstar 27i System 30i System (Provided the optional Integrated Changeover Valve is installed Greenstar CDi Classic System (provided the optional Integrated Changeover Valve manufactured after 02/16/2007 with software version CF12.10 and above is installed))
6
2.2 Montage
2.3 Package content
- RT520 thermostat 2) Back housing 3) 2x AA batteries 4) Short instruction 5) Mounting screws
1
2
3
4
5
2.4 Proper thermostat location
Please note:
The ideal position to thermostat mounting is about 1,5m under floor level far
from heating or cooling sources. Thermostat can’t be exposed to sunlight or
any extreme conditions like for example draft. Because of fire and explosion
risk there is not allowed to use thermostat in atmosphere of explosive gases
and flammable liquids (eg coal dust). In case if any of listed dangers occur
you have to use additional protection measures anti-dust and explosive gases
(tight cover) or prevent their formation. Furthermore, thermostat can’t be
used in condensation of water vapor conditions and be exposed to water action.
7
BPOIOLDELRCCZEONIENEKCOTTILOAN* OPENTHERM
2.5 Connection description
I A – Boiler connection
RT520
NC
3V
2 x AA
COM
NO
(ON / OFF) I B – Pump / Valve connection
AC 230V L
lub
RRTT53210
NC 3V 2 x AA COM
NO
N
MAX 3 (1) A
RT520
3V 2 x AA
A
B
OpenTherm
I C – KL08NSB underfloor heating wiring center connection
Eg.
RT520
COM NO
Eg.
RT520
COM NO
Eg.
RT520
COM NO
KL08NSB L N SL
1 – 8 Zones
Power
LN LN
L N SL or 1 – 8 Zones
LN
L N SL
lub 1 – 8 Zones
Pump
Boiler
LN
1
23
4
BOILER CONNECTION*
AC 230V
L N
T30NC
max 6 per zone
T30NC
max 6 per zone
T30NC
max 6 per zone
Legend:
Boiler – Boiler connection* – Boiler’s contacts for ON/OFF thermostat
(according to the boiler’s instructions)
Pump
M
Valve
8
Symbols explanation:
L, N – power supply 230V NO, COM, NC – voltage-free output A, B – OpenTherm
Communication Wire
SL – 230V AC voltage output – NSB function – fuse
3. Before you start (first power up) 3.1 LCD icon description
1
3A 3B 4
13
14 15 16
1. Text Bar 2. Temperature Unit 3A. Day of the week (numeric) 3B. Day of the
week (alphabetic) 4. Clock 5. AM / PM 6. Cooling Mode On 7. Holiday Mode On 8.
Manual Mode On
3.2 Button description
2
67 5
89 10 11 12
17
9. Heating Mode On 10. Low battery status 11. Wireless connection with the
receiver 12. Service Mode On 13. Temperature measured / set 14. Program number
15. Settings 16. Program indicator 17. Boost function
123456
1. MENU / RETURN – enter the menu options, press and hold for 3 sec to return to main screen or to deactivate Boost or Manual modes. 2. SELECT – confirm changes and enter menus. 3. DOWN – decrease the temperature and move through the menus.
4. UP – increase the temperature and move through menus. 5. BOOST – activate Boost Mode. 6. MANUAL – press once to activate / press and hold for 3 sec to deactivate Manual Mode.
PLEASE NOTE! The LCD screen can be activated by using any button.
9
3.3 First power up sequence and configuration Please make the receiver connections and power the receiver before inserting the batteries into the thermostat.
1
2
3
After inserting the batteries, the thermostat will power up.
4
Press .
5
Using or , choose your language and then press .
6
Using or , choose the time format.
7
Press to confirm.
8
Using or , set the hour and then press .
9
Using or , set the minutes and then press .
10
Using or , set the year and then press .
11
Using or , set the month and then press .
12
Using or , set the day and then press .
10
Using or , select the week format.
Press to confirm.
13
14
15
Using or , enable or disable DST (Daylight Saving Time).
Press to confirm.
16
17
Press .
18
Using or , select your temperature accuracy.
Press to confirm.
When OpenTherm is connected, the device software will automatically adjust to the OpenTherm settings.
11
19
Press .
20
TPI (Time Proportional & Integral) is a self-learning, time-proportional
algorithm. TPI type of regulation ensures economical system operation through
more accurate temperature maintenance during controlling process and limits
overload conditions. In addition to the exact and stable room temperature, the
advantage of this system is the minimization of energy consumption and
significant savings. RT520 offers 3 types of TPI control: 1. for radiator
(6CPH); 2. for underfloor heating (3CPH); 3. for electric heating (9CPH).
21
Using or , select the TPI type you want to use.
22
Span is the difference between the
measured temperature and the set
temperature.
Press to confirm.
Press .
23
24
Using or , select the Span value.
Press to confirm.
12
25
Press .
25
The optimization function is an energy-saving algorithm used for efficient
control of the heating device, ensuring better thermal comfort at certain
times of the day. When the OPTIMUM START function is active, the thermostat
sends a heating signal to the heat source beforehand so that the preset
temperature in the room is reached at the time specified in the schedule.
26
Press .
27
Press .
28
29
Using or , select ON or OFF.
Press to confirm.
When the OPTIMUM STOP function is active, the thermostat, taking into account
the inertia of the system, switches off the heat source earlier, keeping the
temperature set in the schedule.
30
Using or , select ON or OFF.
Press to confirm.
3
The thermostat will go to the main screen.
13
3.4 OpenTherm – Hot Water configuration RT520 can be configured in Hot Water OPENTHERM system. To configure it follow steps below:
1
2
3
Press .
4
Using or , navigate to Hot Water submenu and press .
5
Using or , adjust the temperature and then press .
The thermostat will return to the main screen. Press any button.
3
The text bar indicates that hot water is in operation.
14
4. User settings
4.1 Manual mode
In manual mode, the thermostat maintains a constant temperature set by the
user. To exit mode, press and hold is displayed when manual mode is active.
button for 3 seconds. A hand icon
1
2
3
Press button.
4
A hand icon will appear, which means that thermostat is in manual mode.
5
To set temperature use or button.
Confirm your choice using button.
3
Thermostat will maintain the temperature until manual change or manual mode
exit (press and hold
button for 3 seconds).
15
4.2 Schedule mode – programming schedule
In this mode, user can set the schedules for thermostat (temperature setpoints
for specific periods of time). Programmed schedules should use all time
periods.
1
2
3
Press .
Press .
Using or , select the program type between: 5
+2 (schedule for the working days and for the weekend)
4
All (set one schedule for the entire week)
5
Individual (set a daily schedule).
6
Press to confirm.
7
Using or , set the hour and then press .
Using or , set the minutes and then press .
3
Using or , set the temperature and then press .
Repeat the process for all time periods.
16
4.3 Switching between manual and schedule mode In this option, user can switch between manual and schedule mode by using
button. To do that please follow steps below:
1
2
3
Press button.
3 sec.
A hand icon will appear, which means that thermostat is in manual mode. Now
press and hold button.
3
Thermostat is in the shedule mode again.
17
4.4 BOOST mode – hourly temperature override (+Hr)
The function is available in automatic and manual mode. Used to change the
temperature to the desired value for a specified number of hours (up to 9
hours). After the elapsed time, the thermostat returns to the previous
operating mode.
1
2
3
Press +Hr button to set hour for temporary override (eg. 4 hours = 4 times
button pressing). Confirm by
button.
Using or buttons set the temperature for BOOST mode.
Confirm by button.
3
Thermostat is working in BOOST mode for 4 hours and it will maintain
temperature setpoint for 4 hours.
How to stop BOOST mode:
1
2
Hold
button for 3 seconds or
press +Hr button several times until
“+0″will appear and confirm by
button.
3
Thermostat will go back to main screen and previous work mode.
18
4.5 Control and Heat/Cool settings In this option user can set control algorithm (TPI, SPAN or Optimize) and set Heat / Cool mode. Please follow the steps below:
1
2
3
Press .
4
Using or move between parameters.
Enter using button.
5
6
Using or move between parameters.
Confirm HEAT / COOL option using button.
3
Using or move between parameters. Confirm your choice by
button.
19
4.6 Landlord settings Landlord settings is a pin code protected feature that allows the landlord to set a service reminder on the thermostat that will warn the tenant when the boiler is due its annual service.
1
2
3
Press .
4
Using or , navigate to Landlord submenu and press .
5
Using or , enter the PIN code number. Press to confirm every digit. Note: The
first PIN code entry is also the setting of a NEW PIN CODE which must be
entered each time to enter the LANDLORD (Admin) menu.
6
Please remember to write down your pin code so that you can use the Landlord
menu later without any hassle
from losing it.
7
Press .
8
Using or and press
9
, select ON .
Using or , select the due date and then press .
10
Using or , select the warning period and then press .
11
Using or , select the lock temperature and then press
.
12
Press .
20
Using or , enter the phone number. Press to
confirm every digit.
To confirm and exit this
option use button. Then
use
or buttons
again to move to the next
LANDLORD options (look at
the next steps).
13
14
15
Using or , move to the next option.
Press .
16
17
Using or , select correct MAX temperature setpoint value.
Confirm by .
18
Now, using or , select correct MIN temperature setpoint
value. Confirm by .
Thermostat will go back to SERVICE option. To go back to the main
screen wait 10 seconds or press button as long as main screen will be
displayed.
3
21
4.7 Time/Date To set time/date follow steps below:
1
2
3
Press .
4
Using
5
or move between parameters.
Press
6
to enter Time/Date settings.
Using or , choose the time format. Press to
confirm.
7
Using or , set the hour and then press .
8
Using or , set the minutes and then press .
9
Using or , set the year and then press .
10
Using or , set the month and then press .
11
Using or , set the day and then press .
12
3
Using or , select the week format. Press to confirm.
Using or , enable or disable DST (Daylight Saving Time).
Press to confirm.
Thermostat will go to the main screen with saving all the settings.
22
4.8 Holiday mode Holiday mode is a special program temperature setpoint which thermostat will maintain for specified days. How to set HOLIDAY MODE:
1
2
3
Press .
4
Using
5
or move between parameters.
Press to enter holiday mode settings.
6
Using or , set the year and then press .
7
Using or , set the month and then press .
8
Using or , set the day and then press .
9
Now do the same steps to set holiday mode’s final day.
Using or , set the hour and then press .
Using or , set the minutes and then press .
10
11
12
3
To abort holiday mode just press any button and then confirm HOLIDAY STOP by
button. Plane icon will disappear and thermostat will go back to previous work
mode.
Using or , set the temperature which should be maintaned during holiday mode
and
then press .
According to set period of time the plane icon will appear on the main screen
and thermostat is working in
holiday mode.
23
4.9 Language To choose language follow steps below:
1
2
3
Press .
4
Using or move between parameters.
Press to enter language settings.
5
6
Using or choose your language.
Press to confirm.
3
Thermostat will go to the main screen with saving the changes.
24
5. Factory Reset To RESET RT520 thermostat to it’s factory default settings please follow steps below:
1
2
To reset the thermostat press and hold together + +
buttons for 5 seconds.
3
Thermostat has been reseted. PLEASE NOTE: User settings will not
be deleted.
6. Error codes Thermostat will display errors only when it’s connected to the
boiler by OPENTHERM terminals (A / B). Please refer then to boiler manual.
Each boiler can have different error codes.
7. Battery change Turn the thermostat over so that the back is in front of
you. Now look at the picture below:
INSERT THE BATTERIES, PAYING ATTENTION TO THEIR POLARITY!
25
8. Cleaning and Maintenance
The RT520 thermostat requires no special maintenance. Periodically, the outer
casing can be wiped clean using a dry cloth (please DO NOT use solvents,
polishes, detergents or abrasive cleaners, as these can damage the
thermostat). There are no user serviceable parts within the unit; any
servicing or repairs could only be carried out by Salus Controls or their
appointed agents.
9. Technical Informations
Power supply Rating max Output signal Temperature range Display temperature accuracy Control algorithm Communication Dimension [mm]
2 x AA batteries
3 (1) A OpenTherm (A / B) or voltage free relay (NC / COM / NO) 5 – 33.5°C
0.1°C or 0.5°C
TPI or Hysteresis: ±0.25°C or ±0.5°C
Wired
95 x 118 x 26
95 mm
26
118 mm
95 mm 26 mm
10. Warranty SALUS CONTROLS warrants this product to be free from any defects
in material or workmanship and to perform as specified for a period of five
years from the date of installation. SALUS CONTROLS reserves the sole
responsibility for breach of this warranty by repairing or replacing the
defective product. This product includes software that matches the
distributor’s identification at the time of sale. The manufacturer /
distributor provides a guarantee covering all functions and specifics of the
product in accordance with this marking. The distributor’s warranty does not
cover the correct operation of the functions and features available as a
result of a product software update. The full warranty conditions are
available at www.salus-controls.eu
27
IMPORTER: QL CONTROLS Sp. z o.o. Sp. k. ul. Rolna 4, 43-262 Kobielice
PRODUCER: Salus Limited 6/F, Building 20E, Phase 3, Hong Kong Science Park, 20
Science Park East Avenue, Shatin, New Territories, Hong Kong
www.salus-controls.eu
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc
reserve the right to change specification, design and materials of products
listed in this brochure without prior notice.
Ver. 3 Issued: 19 III 2021 Soft version: 2.2
28
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>