3M MA5532 Tempa-Dot Sterile Clinical Disposable Thermometers User Guide
- June 6, 2024
- 3M
Table of Contents
Clinical Thermometers
SERVICING GUIDE — HOW TO USE/READ
STERILE CLINICAL DISPOSABLE THERMOMETERS
Reduces the Risk of Infection
Temperature-taking devices can be carriers of infectious diseases as they are shared between patients and handled by caretakers. Even with the most stringent cleaning and handling protocols, it is difficult to insure a contaminate-free device for each use. Tempa•DOT™ solves this problem by providing a sterile, individually wrapped, disposable thermometer. Simply open, use and dispose of. In the long history of Tempa•DOT™, there has not been a documentable instance of a patient-induced infection. A reduced infection rate can translate into improved patient outcomes, and lower costs.
- REDUCES THE RISK OF INFECTION — Other temperature-taking devices can accumulate, carry, and spread contagions as they are routinely handled. By comparison, Tempa•DOT™ is a sterile instrument, individually wrapped for single use. This virtually eliminates the possibility of contaminating transfer. There is a strong case for the use of Tempa•DOT™ with all patients. The prevention of just one HAI event can pay for the entire Tempa•DOT™ program. •
- ACCURATE — Oral readings in 1 minute. Accurate to ±0.1°C (within the critical range of 37.0°C to 39.0°C). • SAFE— Tempa•DOT™ is sterile, latex-free, and non-toxic. Individually wrapped to prevent contamination before use. •
- CONVENIENT — Units are easily divisible and transportable. Place a 100-count box in each patient’s room, or carry individual 4-strips. They fit comfortably in the pocket of your scrubs.
- ECONOMICAL — Eliminates time and materials spent to disinfect, recalibrate, recharge, or repair electronic devices. No need to purchase and stock disposable (unsterilized) sheaths, or enter into long-term purchasing commitments.
HOW TO STORE
Store Tempa•DOT™ thermometers in an area where temperatures do not exceed
30°C.
When exposed to high temperatures, matrix dots will turn blue. If this occurs:
- Place in freezer for 1 hour per box of 100, 16 hours per case of 20 boxes. (2 hours per box for Tempa•DOT™ PLUS rectal thermometers.)
- Let stand at room temperature for 1 day.
- Thermometers are now ready for use. Dots may appear slightly off-color, but this does not affect accuracy.
HOW TO OPTIMIZE RESULTS
As with all medical instruments, it is important to closely follow the IFUs:
– Position in mouth correctly.
– Keep your mouth closed for the full 60 second period.
– Read the last blue dot after the device “locks in” (approx. 10 seconds).
Ignore any skipped dots.
– Retake temperature with new device if left in the mouth longer than 2
minutes (oral) or 5 minutes (axillary or rectal).
– Wait at least 15 minutes before taking temperature when patient is exposed
to cold weather, smoking, eating, or drinking.
– Do not use after the expiration date, which is printed on the 100 count box.
– If the thermometer wrapper has been damaged or opened, the product may no
longer be sterile. Please discard.
ORAL USE
-
OPEN PACKAGE
Fold along perforation and tear off a single Tempa•DOT™ thermometer strip. Peel back top of wrapper to expose handle of the thermometer. Remove thermometer by pulling the exposed handle, taking care not to touch the dot matrix portion which is to be placed in the patient’s mouth. -
INSERT THERMOMETER AND WAIT 60 SECONDS
Place a thermometer into the patient’s mouth under the tongue, as far back as possible into either heat pocket, as you would any oral thermometer (see diagram). Generally, adult lips should touch the middle of the “Tempa•DOT” logo. The dots can face either up or down. Have the patient press tongue down on the thermometer while keeping the mouth closed. -
REMOVE THERMOMETER 9 3 AND WAIT 10 SECONDS
-
READ AND RECORD TEMPERATURE
The last blue dot on the matrix indicates the correct temperature (ignore any skipped dots). Retake temperature with the new device if left in the mouth for longer than 2 minutes. -
DISCARD THERMOMETER
Ordering Information:
Tempa•DOT # 5532 standard (°C Scale)
Tempa•DOT # 5538 standard (°C Scale)(UK only
AXILLARY USE
-
OPEN PACKAGE
Fold along perforation and tear off a single Tempa•DOT™ thermometer strip. Peel back top of the wrapper to expose the handle of the thermometer. Remove the thermometer by pulling the exposed handle. -
INSERT THERMOMETER AND WAIT 3 MINUTES
Place thermometer high in the armpit with the dot matrix side against the torso and parallel to the length of the body. Use the patient’s arm to hold the thermometer in place. -
REMOVE THERMOMETER AND WAIT 10 SECONDS
Before reading, wait approximately 10 seconds for dots to lock-in. -
READ AND RECORD TEMPERATURE
The last blue dot on the matrix indicates the correct temperature (ignore any skipped dots). Retake temperature with the new device if left underarm longer than 5 minutes.
Ordering Information:
Tempa•DOT # 5532 standard (°C Scale), or
Tempa•DOT # 5002 with an adhesive strip (°C Scale)
Tempa•DOT # 5538 standard (°C Scale)(the UK only)
RECTAL USE
-
PREPARE THERMOMETER
Inspect sheath. Do not use if malformed or damaged. Insert thermometer completely into the sheath, dot-end first and with dots visible through the smooth side of the sheath. -
INSERT THERMOMETER AND WAIT 3 MINUTES
Lubricate the sheath exterior and insert the thermometer with the sheath into the rectum until the dots and numbers are completely covered.
CAUTION: Any object inserted into the rectum could cause perforation. DO NOT USE FORCE. -
REMOVE THERMOMETER AND WAIT 10 SECONDS
Discard sheath. Before reading, wait approximately 10 seconds for the dots to lock in. -
READ AND RECORD TEMPERATURE
The last blue dot on the matrix indicates the correct temperature (ignore any skipped dots). Retake temperature with the new device if left in the rectum longer than 5 minutes. -
DISCARD THERMOMETER
Ordering Information:
Tempa•DOT # 5502R (°C Scale)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>