Introduction
Congratulations on the purchase of your new 3M™ Littmann® Classic II Pediatric
Stethoscope or Littmann Classic II Infant Stethoscope.
These two-sided models with traditional bell/ diaphragm chestpieces are
designed, sized and acoustically precise for children and infants. The solid
stainless steel chestpiece features a one-inch traditional bell (pediatric) or
a ¾ bell (infant) combined with a floating diaphragm.
Other features include a comfortably angled, anatomically correct headset,
excellent acoustic seal and comfortable fit with patented 3M™ Littmann® Snap
Tight Soft-Sealing Eartips, and single-lumen tubing in attractive colors for
use with children and infants.
Most of all, know that your Littmann Classic II Pediatric or Classic II Infant
stethoscope carries the Littmann brand name, the name known worldwide for
unsurpassed quality. As a trusted leader in auscultation technology, the
Littmann brand of stethoscopes is your assurance of acoustical superiority,
innovative design and exceptional performance.
Instructions for Use Chestpiece
On 3M™ Littmann® Classic II Infant or Pediatric stethoscopes with traditional
combination Chestpiece, you select either the diaphragm or open bell side by
holding the chestpiece stem in one hand and rotating the chestpiece with the
other hand until a click is felt.
Low frequencies: Use light contact on the bell side to hear low frequency
sounds.
High frequencies: Turn the chest piece over, index to the opposite side and use firm pressure to hear high-frequency sounds.
Headset Adjustment
Your Littmann stethoscope is designed to provide a comfortable, acoustically
sealed ear fit. Notice that the headtubes are set to accommodate the typical
anatomy of the ear canal.
The ear tips should point in a forward direction as you insert them into your
ear canals.
To reduce spring tension in the headset, hold each earthbag at the bend near
the ear tip and gradually pull apart until fully extended.
To increase spring tension, grasp the headset with one hand where the earbobs enter the plastic tubing and squeeze until the plastic tubing on one eatable touches the other. Repeat as necessary.
For maximum acoustic performance, comfortable patented 3M™ Littmann® Snap
Tight Soft-Sealing Ear tips are provided with your stethoscope.
This stethoscope utilizes a unique design for attaching the ear tip to the
earthbag. The ear tips are pushed on to the end of the earthbag and snapped
firmly into place. To remove, pull firmly on the ear tip.
Removing the Diaphragm and Cleaning the Chestpiece
With the diaphragm side up, push the rim at one point with both thumbs and
roll the rim off the edge of the Chestpiece.
Remove the diaphragm from the rim and clean parts in soapy water or wipe with
alcohol.
Wipe Chestpiece surfaces with alcohol or soapy water. Dry all parts and
surfaces thoroughly before reassembly.
Replacement of the Diaphragm
Place diaphragm on Chestpiece surface. Totally engage diaphragm and Chestpiece edge in groove of rim at one point, and hold in place with thumb. While maintaining rim engagement at one point, roll rim over the entire outer edge. Make sure diaphragm is completely contained in groove of the rim.
General Use and Maintenance
- Avoid extreme heat, cold, solvents, and oils.
- The entire stethoscope can be wiped clean with alcohol or soapy water.
- Ear tips can be removed from the earbobs for thorough cleaning.
NOTE: Do not immerse your stethoscope in any liquid or subject it to steam sterilization. If disinfection is required, the stethoscope may be wiped with a 70% isopropyl alcohol solution.
3M™ Littmann® Stethoscope Service and Warranty Program
Your 3M Littmann stethoscope comes with the finest service and warranty policy
in the industry.
The 3M™ Littmann® Classic II Infant or Pediatric Stethoscopes are warranted
against any defects in material and workmanship for a period of three (3)
years. If a material or manufacturing defect is discovered during the warranty
period, repairs will be made without charge upon the return of the instrument
to 3M, except in cases of obvious abuse or accidental damage.
For maintenance or repair services, write a short note explaining the repair or service you require, include your name, address and phone number and send your stethoscope directly to:
3M Health Care Service Center
Bldg. 502, Suite 200
3350 Granada Ave. North
Oakdale, MN 55128
1-800-292-6298
IN CANADA:
3M Canada
Service and Repair Depot
1798 Oxford Street East
London, Ontario, Canada
N5V 3R6
1-800-268-6235
Outside of the U.S. and Canada please contact your local 3M subsidiary for maintenance and repair information
Explanation of Symbols
Attention, see instructions for use.
This product and package do not contain natural rubber latex.
3M, Littmann, the L Littmann logo, and the L are trademarks of 3M, used under
license in Canada.