Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is double insulated and does not require connection to
an earth circuit.
Please read these instructions carefully before commencing any work
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building
Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or
maintaining this fitting. Ensure other persons cannot restore the electrical
supply without your knowledge.
This light fitting should be connected to a circuit with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note of the connections
This product is suitable for covering with insulation 300mm. This product
complies with Building Regulations Part B and is suitable for use in 90 minute
fire rated ceilings.
This system contains non-replaceable parts and cannot be serviced. If damage
occurs the part shouldbe scrapped. Cables must be protected using suitable
conduit or plastic trunking.
The external flexible cable or cord of this luminaire cannot be replaced. If
the cord is damaged, the luminaire must be destroyed.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or
retailer for recycling advice.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will
reach the distances between each light fitting.
Avoid locating any cables in positions that would cause a hazard. Position
cables and junction boxes (not supplied) away from areas where they may be at
risk from being cut, trapped or damaged.
The mains supply cable must have a minimum cross section area of 1.0mm2.
When more than one downlight is installed, the minimum distance between units
is 500mm. the unit must be located a minimum distance of 50mm from a joist.
This product must be mounted out of arms reach.
This product is suitable for use in outside zones of a bathroom only. Please
see diagram. 2.25m Zone 1 0.6m Outside zones
If this unit is being fitted in a room containing a bath or shower, a 30mA RCD
must be used – in accordance with IEE regulations.
Installation
Exising fittings must be completely removed before installation of a new
product. Before removing the existing fitting, carefully note the position of
each set of wires. The ceiling surface must be flat and smooth to ensure a
good fit. Note that the switch is turned off before installation. Ensure that
the screws and cable entry points are sealed to maintain the IP rating of the
product.
This product is colur changing and can be either warm white (3000K) or
cool white (4000K) or daylight white (6000K). Choose your preferred
colour before installing by using the CCT switch.
Position the LED Driver next to mains outlet that the system will connect to
do not connect at this stage.
- Cut a mounting hole 90mm diameter in the ceiling taking care not to foul any pipes, mains cables or joists beneath the surface. It is always recommended to cut the hole slightly smaller than the size specified, and then file the hole until the recessed unit fits snugly.
- Ensure a minimum ceiling void depth of 45mm is available.
- Pull the mains wire through the hole and wire as detailed wiring.
- Push the spring clips upwards and fit into the ceiling hole, then push the unit up until firmly in position, ensuring that no cables are trapped. Ensure that the product is sitting properly in the hole. · Adjust the tilt before switching on.
- Switch on. Your light is now ready for use.
Wiring
Check that…
You have correctly identified the wires.
The connections are tight.
No loose strands have been left out of the connection block.
Technical data
Supply Voltage: 220-240 V~, 50 Hz
Bulb Type: 8W LED module (SMD) CCT, 3000/4000/6000K
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
Conformity with all relevant EC Directive requirements.
The power supply is Double Insulated and does not require connection to an
Earth circuit.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your Local Authority or
local store for recycling advice.
This product is suitable for dimming.
This product is fire rated to 90 minutes.
This product is rated at IP44.
Care and Safety
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish. For your safety, always switch off the power supply before cleaning.