Safety Instructions
- Before using the device, read the operating manual and follow the instructions contained in it. The manufacturer is not liable for damages caused by using the device contrary to its intended purpose or improper operation.
- The device is for home use only. Do not use for other purposes that are not for its intended purpose.
- The device should only be connected to an AC outlet with a grounded 220-240V ~ 50Hz. To increase operational safety, multiple electrical devices should not be connected to one current circuit at the same time.
- Use extreme caution when using the device when children are nearby. Do not allow children to play with the device, do not allow children or people unfamiliar with the device to use it.
- WARNING : This equipment may be used by children over 8 years of age and people with limited physical, sensory or mental ability, or people who have no experience or knowledge of the equipment, if this is done under the supervision of a person responsible for their safety or have been granted them information on the safe use of the device and are aware of the dangers of using it. Children should not play with the equipment. Cleaning and maintenance of the device should not be performed by children, unless they are over 8 years old and these activities are carried out under supervision.
- Always disconnect the power plug by holding the socket with your hand after use. DO NOT pull on the power cord.
- Do not immerse the cable, plug and the whole device in water or any other liquid. Do not expose the device to atmospheric conditions (rain, sun, etc.) or use in conditions of high humidity (bathrooms, damp mobile homes).
- Periodically check the condition of the power cord. If the power cord is damaged, it should be replaced by a specialist repair shop to avoid danger.
- Do not use the appliance with a damaged power cord or if it has been dropped or damaged in any other way or if it is not working properly. Do not repair the device yourself, as there is a risk of electric shock. Take the damaged device to an appropriate service center for checking or repair. All repairs may only be carried out by authorized service points. Incorrectly performed repairs can cause serious danger for the user.
- Place the device on a cool, stable surface, away from hot kitchen appliances such as: electric stove, gas burner, etc.
- Make sure that nothing is blocking the air inlet and outlet of the device
- Use the device only on a level surface to prevent the condensation from spilling out
- To provide additional protection, it is advisable to install a residual current device (RCD) in the electric circuit with a rated residual current not exceeding 30mA. Ask an electrician for this.
- Clean the air filter regularly. The frequency of cleaning depends on the cleanliness of the air.
- After turning off the machine, wait at least 5 minutes before turning it back on.
- Do not use the device in sunny places. When the device overheats, the overheat protection will switch on the device.
- To ensure effective cooling, a distance of at least 50 cm should be kept between the side walls of the device and the wall or furniture or curtains.
- Due to the limited performance of the device, if the difference between the target temperature and the ambient temperature is too great, the target temperature may not be reached.
- To reduce the risk of fire, electric shock or injury when using the air conditioner, observe the following basic precautions:
- Connect to a grounded outlet with 3 pins.
- Do not remove the grounding prong.
- Do not use the adapter.
- Do not use an extension cord.
- Disconnect the air conditioner before servicing.
- Use two or more people to move and install the air conditioner.
- Do not use agents accelerating the defrosting or cleaning process other than those recommended by the manufacturer.
- The device should be stored in a room without constantly operating sources of ignition, for example: open fire, gas appliances or electric heaters.
BEFORE FIRST USE
When moving the device make sure that it is in an upright position. Before
using the air conditioner keep it upright for 2 hours at least.
Device Description – LOCAL AIR CONDITIONER CR7929 – Picture A
- Control panel
- Cold air outlet
- Remote controller (picture E)
- Handle
- Air inlets
- Air exhaust pipe
- Exhaust connector
- Drain hole with rubber cap (picture F)
- Window exhaust adapter
- Connector of air exhaust pipe
- Filter’s frame
- Nylon filter
- Drain plug
Control Panel Description – Picture D. A. Power button
C. Temperature down / timer down button in cooling mode
D. Temperature up / timer up button in cooling mode
E. Sleep model button
F. Fan mode button
G. Timer button
H. Automatic air oscillation button
I. LED screen
J. Cool mode button
K. Dehumidifying button
L. Slow fan speed button
M. Fast fan speed button
N. Water full indicator light
Remote controller – Picture E
A. Power button
B. Mode selection button
C. Temperature/timer down button
D. Temperature/timer up button
E. Sleep mode button
F. Fan speed selection button
G. Timer button
H. Air oscillation button
CONTROL PANEL manual operation – picture D
When the is powered on for the first time, the buzzer will shout, and then the device will get into standby status. Press button “A” to turn on and turn off the device, the buzzer will play signal once.
MODE SELECTION on manual operation of control panel –
When the device is power on, choose mode you need between cooling mode or fan
mode or dehumidifying mode as below:
Cooling mode –
Press button “J” to select cooling mode, next press the button “L” to get slow
fan speed button or press the button “M” to get fast fan speed button. Next
press button “ C” or “ D” to adjust required temperature from 16℃ to 31℃,
buttons are not available in fan or dehumidifying mode.
Fan mode –
– Press button “F” to select fan mode, the LCD screen will show “FA”, next
press the button “L” to get slow fan speed button or press the button “M” to
get fast fan speed button. During fan mode operation the temperature and
sleeping functions cannot be setup.
Dehumidifying mode –
– Press button “K” to select dehumidifying mode, the LCD screen will show
“dh”. Under dehumidifying mode, sleep mode cannot be setup, and fan speed is
fixed on slow fan speed automatically and cannot be changed. In order to
switch off the dehumidifying mode select other operation mode: cooling or fan
mode.The function of drain plug (13) is to drain the condensate water from the
device’s upper part. Its use is determined according to the local air
humidity. It is need to open the drain plug (13) and pour out the condensate
water if the device operates when local air humidity is high or the device
operates on dehumidification mode continuously for 12-24 hours continuously.
In dry cooling mode (low air humidity) it is not necessary to open the drain
plug (13) because there is no need to drain the condensate.
Timer set up
- When the device is not working, press button “G”, the LCD screen flashes, press the button “C” or “D” to set up the quantity of hours after the device will start to operate. The LCD screen stops flashing and timer icon will be illuminated.
- When the device is working, press button “G”, the LCD screen flashes, press the button “C” or “D” to set up the quantity of hours need to pass before the device will shut off automatically. The LCD screen stops flashing, the timer icon will be illuminated, LCD screen shows required to achieve temperature. This is a delayed start function. Timer operation range can be fixed by each one hour from 1 to 24 hours.
Sleep mode
- At first Press button “J” to cooling mode, next press button “E” to turn on the sleep mode, then the device will work on Energy-Saving and quiet type.
- Next press button “ C” or “ D” to adjust required temperature from 16℃ to 31℃.
- The sleep mode is automatically programmed. After the first hour of operation, the temperature will increase by 1 ℃, after the second hour of operation, the temperature will increase by another 1 ℃, and then remain at the same level.
- Press button “E” again to cancel sleep mode.
NOTE : Sleep mode is not available in dehumidify and fan modes.
Water full –
The water full indicator lamp “N” will be illuminated and the buzzer will alarm for several second, then the compressor will stop to work when the inner device water tank will be full.
Automatic air oscillation function –
Press an air oscillation button (H), after the device turns on, automatic air oscillation function turns on, the louver will swing continuously the left and the right; by pressing the button again the movement will stop and the louver remain in that position. The radius of horizontal air oscillation is 30 degrees left and 30 degrees right direction from the middle vertical.
REMOTE CONTROLLER operation – picture E
The remote controller transmits signals to the system.
Button “A” – the device will be started when it is energized or will be
stopped, if you press this button again.
Button “B” – press it to select operation mode: cool mode → dry mode →
fan mode.
Button “C” / “D” – press to set up the operation time from 1 to 24 hours
or required room temperature from 15 to 31°C when cooling mode is switched on.
Button “E” – press it to set up or cancel sleep mode.
Button “F” – press it to select fan speed in sequence: slow / fast wind
speed. Button “G” – press it to set up or cancel timer.
Button “H” – press to set up or cancel automatic air oscillation
function.
PROTECTION DEVICES
1. Compressor protection: Three minutes later after power on / restart,
compressor starts to run.
2. Overflow protection function: when the water full indicator lamp “N” will
be illuminated and the buzzer will alarm for several second, the device turn
off automatically. In this case, you need to drainage the water (details see
Drainage Instructions at the end of this chapter). After the water is emptied,
the device will get into standby status.
3. Frost Protection Function: In cooling mode, if the temperature of the EVA
pipe sensor is too low, the device will automatically enter protection status.
When the temperature of the EVA pipe sensor rises to a certain temperature, it
can automatically revert to normal operation.
DRAINAGE INSTRUCTIONS:
This device is equipped in auto-water-evaporating system. Condensed water
cycle will cool down the condenser, which will not only improve cooling
efficiency, but also save energy.
1. If inner water tank is full, the water full indicator lamp “N” will be
illuminated, the device enter into standby mode, buzzer shouts, compressor
stops and all buttons is invalid till the device recovers to be normal, after
water drainage.
2. Power off the device.
3. Prepare flat container (not included to set) to drain the water. Locate it
under the drain hole (8)
3. Remove the rubber cap from the drain hole (8) – picture F.
4. During drainage, the body can be tilted slightly backwards.
5. After water stops to pouring out, close the rubber cap (8).
6. Restart the device, the device will runs normally.
CLEANING & MAINTENANCE
Cleaning : before cleaning and maintenance, turn off the device and unplug the plug.
a) Housing cleaning
Clean with surface of device with a wet soft cloth. Don’t use chemicals, such
as benzene, alcohol, gasoline, otherwise, the surface of the device will be
damaged or even the whole device will be damaged.
b) Net nylon filters cleaning
If nylon filter (12) is clogged with dust, then the effectiveness of the
device is reduced, be sure to clean the filter once every two weeks. – Force
down from the outside the latch of filter frame (11) with hands and pull out
to yourself to remove the filter frame(11).
- Clean the upper and down filters frame (11) after remove both nylon filters (12) from the filter frame(11). – picture G.
- Put nylon filter (11) into warm water with neutral detergent (about 40℃ / 104℉) and dry it in the shade after rinsing clean.
STORAGE
If the device will be unused for a long time, please do as following:
1. Pull out drainage plug (8) to flow out water.
2. Let the device runs under fan mode for 2 hours to dry out the device’s
internal.
3. Turn off the device and pull out plug .
4. Clean and dry filters, then reinstall them.
5. Pull out exhaust pipe for safe keeping .
6. Put the device into plastic bag , and place it on a dry place.
7. Remove batteries of the remote control and keep them properly. Storage the
device and all device components in dry place.
TROUBLESHOOTING
Problem I.: The air conditioning does not work.
Reason 1: There is no electricity. So, turn it on after connecting it to
a socket with electricity.
Reason 2: The water full indicator light “N” is illuminated. So,
discharge the water.
Problem II.: The device auto-restarts frequently.
Reason1: Direct sunlight. So, drawn the curtains.
Reason 2: Door and windows are open , many heat sources in the room. So,
close the door and windows, move out heat sources.
Reason 3: Filters are too dirty. So, clean or replace filters.
Reason 4: Air-inlet or air out-let is blocked. So, remove blockage.
Problem III.: Big Noise
Reason : The device is not placed on a flat surface. So, put the device on a flat and hard place to reduce noise.
Problem IV.: Compressor does not work.
Reason : Compressor time-delay protection turn on. So, wait for 3 minutes
until the temperature is lowered, and then restart the device.
Note : when abnormal situations are occurred, turn off device and pull
out plug, then contact with professional service for help. Do not repair the
device yourself. Not qualified repair will void the warranty.
TECHNICAL DATA:
- Cooling capacity at BTU: 9000 BTU / hour
- Cooling capacity in watts: 2640W
- Energy consumption (cooling) in watts: 1010 W Noise level: <= 65dB
- Air flow: 350 m3 / hour
- Energy class: A
- Drying capacity: 24 liters / 24 hours
- Cooling agent: R290 210 grammes
Caution, risk of fire.
Do NOT pierce or burn. Be aware that the refrigerant may not contain an odour.
Read User Manual Online (PDF format)