FLUVAL 10525 Spec 60 L Aquarium Kit User Guide

June 5, 2024
FLUVAL

FLUVAL 10525 Spec 60 L Aquarium Kit

IMPORTANT SAFETY INSTRUCTIONS

WARNING – To guard against injury, basic safety precautions should be observed, including the following:

1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2. DANGER – To avoid possible electrical shock, special care should be taken since water is employed in the use of aquarium equipment.
3. Never attempt to repair this appliance yourself. Return the appliance to an authorized service facility for service or discard the appliance. Do not operate the appliance if it has a damaged cord or plug. If cord is damaged, the appliance should be destroyed.
A. If the appliance falls into the water, DO NOT reach for it. First unplug the appliance and then retrieve it from the water. If electrical components of the appliance get wet, unplug it immediately and allow the appliance to thoroughly dry. Carefully examine the appliance after installation. It should not be plugged in if water is present on parts not intended to be wet.
B. To avoid the possibility of the appliance plug getting wet, position the tank to the side of a wall mounted receptacle to prevent water from dripping onto the receptacle. A “drip loop”, should be arranged by the user for each cord connecting an aquarium device to the receptacle. The “drip loop” is the part of the cord below the level of the receptacle or the connector if an extension cord is in use, to prevent the water from travelling along the cord and coming into contact with the receptacle. If plug or receptacle gets wet, DO NOT un-plug the cord. Disconnect the fuse or circuit breaker that supplies power to the receptacle then unplug the transformer and examine for the presence of water in the receptacle.
4. WARNING – This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
5. Always unplug the appliance from the outlet when not in use, before putting on or taking off parts and before cleaning. Never yank the cord to pull the plug from the outlet.
6. Do not use this appliance for any purpose other than that recommended by the manufacturer. The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition.
7. Do not install or store the appliance where it will be exposed to weather or temperatures below freezing.
8. Make sure the appliance is mounted correctly and securely positioned on the aquarium before operating the appliance.
9. Read and observe all important safety notices on the appliance.
10. If an extension cord is necessary, a cord with the proper current (amps) rating should be used. A cord rated for fewer amps than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.
11. This appliance is intended FOR INDOOR HOUSEHOLD USE ONLY.
12. This appliance is for use with Freshwater only. Not for saltwater use.
13. (For North America only) This appliance has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit in a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If the plug will still not fit fully into the outlet, contact a qualified electrician to inspect the outlet and make the needed alterations. Never use with an extension cord unless the plug can be fully inserted. Do not attempt to defeat this safety feature.

SAVE THESE INSTRUCTIONS

CONTENTS

  FLUVAL 10525 Spec 60 L Aquarium Kit 1

Please review the following diagram to ensure you have all of the necessary components included with your SPEC aquarium:

INSTALLATION

  • STEP 1. Connect pump to outlet

  • STEP 2. Insert Filter Media

  • STEP 3. Insert Heater

  • STEP 4. Add Gravel & Decor

  • STEP 5. Connect the light

Lower light into place while threading electrical cord through cut-out on cover. Connect cord to transformer and plug into electrical outlet. Convenient touch-switch offers three different On modes (White & Blue, White Only, and Blue Only), as well as an Off mode.

NOTE: Once you’ve added gravel and decorations, your tank will need to be “cycled” (free of Ammonia and Nitrite) before you add fish. To learn more about this process, please visit: www.FluvalAquatics.com/cycling

ADDING LIVESTOCK

Consult your fish dealer for species specific care requirements.

CARE & CLEANING

DAILY WEEKLY MONTHLY

Feed fish in the morning after the lights have come on, and again in the evening before the lights go off.|

Change 20% of water every two weeks.

| Clean Foam Filter once a month by rinsing it thoroughly with tap water.
Check for any signs of pump malfunction by ensuring there is visible water circulation.|

Replace Carbon media

Using a net, remove any excess food or other debris as needed.| Clean the glass using magnets (sold separately) as needed (usually once or twice a week), while being careful not to get particles in between the magnet and the inside glass.| Replace Bio-Foam once every 6 months.
Check thermometer (not included) to ensure optimal range (76-80° Fahrenheit, 24-27°Celsius) is being maintained.|

Replace BIOMAX media once every 2-3 months.

TECHNICAL

LED LAMP| FILTER
WATTS| 16 W| PUMP OUTPUT 500 L/h (132 US gal./h)
LUMENS| 1272 lm| Replacement Filter Media (sold separately)


10532                   A1377

Foam               Carbon

| ****


A1378

Biomax

COLOR TEMP.| 7000 K
LEDs| 31
HOURS| 50000

RECYCLING

This product bears the selective sorting symbol for waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European Directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment. Check with your local Environmental Agency for possible disposal instructions or take to an official council registered refuse collection point. Electronic products not included in the selective sorting process are potentially dangerous for the environment and human health due to the presence of hazardous substances.

TWO YEAR LIMITED WARRANTY

Your Fluval SPEC aquarium and included electrical components are guaranteed for defects in material or workmanship for a period of two years from the date of purchase. This guarantee is valid with proof of purchase only. The guarantee is limited to repair or replacement of the unit only and does not cover consequential loss or damage to animate or inanimate objects. This guarantee is valid provided the aquarium is placed on a surface that is flat and levelled. This guarantee excludes aquarium breakage due to misuse, chips, stress cracks caused by improper support or other breakage. This guarantee is valid only under normal operating conditions for which the unit is intended. It excludes any damage caused by unreasonable use, negligence, improper installation, tampering, abuse or commercial use. Failure of less than 5% of the total number of LEDs shall not be considered a defect under the terms of this warranty. The warranty does not cover the impeller, or any item which has not been adequately or correctly maintained. This guarantee does not affect your statutory rights. To register your warranty online or for more information on this and other products go to www.hagen.com If at sometime in the future you have cause to claim under this guarantee, you will need to provide proof and date of purchase. We recommend that you retain your receipt for this purpose. Rolf C. Hagen Inc. wishes you many hours of enjoyment with your Fluval SPEC aquarium.

FOR AUTHORIZED GUARANTEE REPAIR SERVICE

For Authorized Warranty Service please return (well packaged and by registered post) to the address below enclosing dated receipt and reason for return. If you have any queries or comments about the operation of this product, please let us try to help you before you return the product to your retailer. Most queries can be handled promptly with a phone call. When you call (or write), please have all relevant information such as model number, age of product, details of aquarium set-up, as well as the nature of the problem. If you have any queries or comments about the operation of this product, please contact your Specialist Aquatic Retailer in the first instance. Most queries can be handled easily at store level. In the unlikely event that it cannot, please return the item to the retailer, with your valid proof of purchase, for repair or replacement under the two year warranty terms.

CANADA: Rolf C. Hagen Inc., Consumer Repair
20500 Trans Canada Hwy, Baie D’Urfé, QC H9X 0A2 Canada only: 1-800-554-2436 between 9:00 a.m. and 4:30 p.m. Eastern Standard Time. Ask for Customer Service.

U.S.A.: Rolf C. Hagen (U.S.A.) Corp.
305 Forbes, Blvd, Mansfield, MA. 02048 U.S.A only: 1-800-724-2436 between 9:00 a.m. and 4:00 p.m. Eastern Standard Time. Ask for Customer Service.

UK: Rolf C. Hagen (UK) Ltd, Customer Service Department

California Drive, Whitwood Ind Est., Castleford West, Yorkshire WF10 5QH http://[faq.hagencrm.com](http://faq.hagencrm.com)?/uk

U.K. only: Helpline Number 01977 521015. Between 9:00 AM and 5:00 PM, Monday to Thursday and 9:00 AM and 4:00 PM on Friday (excluding Bank Holidays).

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals