Important Safety Instructions

Please save these instructions.

This manual contains important safety, installation, and operating instructions for the charge controller. The following symbols are used throughout the manual to indicate potentially dangerous conditions or important safety information.

Indicates a potentially dangerous condition. Use extreme caution when performing this task

Indicates a critical procedure for safe and proper operation of the controller

Indicates a procedure or function that is important to the safe and proper operation of the controller.

General Safety Information

  • Read all the instructions and cautions in the manual before beginning the installation.
  • Chance to strip nuts and bolts exists.
  • Do NOT substitute parts from other manufacture ring sources, doing so may void the warranty and/or result in an unstable system
  • This system is NOT possess any compliance with residential structural codes and should not be used in place of a system that is, if so required by local regulations

Installer Responsibilities

  • Installation compliance with any applicable codes which are in force at the installation site.
  • Installation compliance and compatibility with all system components and the environment including but not limited to roofing, system components, etc.
  • Verification that all project information is accurate

This equipment should be installed, adjusted, and serviced by qualified electrical maintenance personnel familiar with the construction and operation of the equipment and the hazards involved. Failure to observe this precaution may result in bodily injury. Protective gloves and safety glasses should be worn during installation.

General Information

The Renogy Tilt Mount will support various mounting applications, especially in off-grid. It is suitable for most Renogy panels and can be mounted on any flat surface. This mount is designed to allow some adjustment of the panel’s angle for optimum performance. The angle adjustability is dependent on the panel size, with larger panel sizes decreasing angle adjustability.

Key Features

  • 5052-H32 aluminum construction
  • Stainless steel fasteners
  • High-tensile strength
  • Precision hole positioning and alignment
  • Easy, rapid assembly
  • Corrosion Free
  • Attractive brushed aluminum finish

Angle Adjustability

The angles for the Renogy Tilt Mount are based off a landscape panel installation. As the solar panel size increases, the angle freedom decreases.

The following angles are a general framework based on extension bracket length. The minimum angle maximizes the extension bracket length while the maximum angle minimizes the extension bracket length.

RENOGY MTS-TM100 Flat Roof Tilt Mount - Maximum Angle°

Maximum Angle°

RENOGY MTS-TM100 Flat Roof Tilt Mount - Minimum Angle°

Minimum Angle°

RENOGY MTS-TM100 Flat Roof Tilt Mount - Angle
Adjustability

Identification of Components

RENOGY MTS-TM100 Flat Roof Tilt Mount - Identification of
Components

RENOGY MTS-TM100 Flat Roof Tilt Mount - Identification of Components
2

Installation

The equipment should be installed, adjusted, and serviced by a qualified electrical maintenance personnel familiar with the construction and operation of the equipment and hazards involved. Failure to observe this precaution may result in bodily injury. Protective gloves and safety glasses should be worn during installation.

The stripping of the threads on the nuts and bolts is possible.

Recommended Tools (Not provided)

  • Socket wrench
  • Torque extension
  • High-tensile strength
  • 18mm wrench or socket for larger hex nut
  • 13mm wrench or socket for smaller hex nut
  • Box-Leveler
  • Tape Measure

The above tools and equipment are highly recommended to have available to assist with installation but are in no way a comprehensive list of tools that can ease installation.
Installers feel free to substitute comparable equipment where appropriate.

Fasten L-Joint to Back of Solar Panel

All Cap Head Bolts must have a Spring Washer and Washer before feeding through a hole. A washer will also need to be placed behind the hole before the nut.

The back of the L-Joints face away from the panel’s longitudinal center.

RENOGY MTS-TM100 Flat Roof Tilt Mount - Fasten L-Joint to Back of Solar
Panel

Attach L-Joint to L-Bracket Foot

The mounting angle demonstrated in the image is to serve as a guide for users and their individual assemblies.

RENOGY MTS-TM100 Flat Roof Tilt Mount - Attach L-Joint to L-Bracket
Foot

Attach Extension Bracket to L-Joint

RENOGY MTS-TM100 Flat Roof Tilt Mount - attach Extension Bracket to
L-Joint

RENOGY MTS-TM100 Flat Roof Tilt Mount -a ttach Extension Bracket to L-Joint
2

Attach L-Bracket Foot to Extension Bracket

The mounting angle of the Extension bracket relative to the L-Joint can change based on user needs.

RENOGY MTS-TM100 Flat Roof Tilt Mount - Attach L-Bracket Foot to Extension
Bracket

RENOGY MTS-TM100 Flat Roof Tilt Mount - Attach L-Bracket Foot to Extension
Bracket 2

Mounting Recommendations

The following information is intended to be a basic guide to give the user a basic approach to mounting. A proper roof-mounting guide should be consulted prior to beginning any installation.

There are various fastening techniques, but some of the most common situations call for the use of a lag bolt. This method is common when mounting panels onto a roof with a wood or asphalt surface. The following is a basic approach and should be taken as such.

  1. Find a desired mounting location
  2. Drill 4 holes where the holes on the L-Bracket Feet line up. A power drill with a sufficient drill but should be utilized in this process.
  3. After the hole has been drilled, silicone sealant needs to be administered to the hole in order to prevent leaks.
  4. Use a power drill with socket extension to drill the lag bolt into the hole.
  5. Drill until sufficient load is applied.

Dimensions

The following drawings utilize inches as their dimension units.

Inner Extension Bracket

RENOGY MTS-TM100 Flat Roof Tilt Mount - Inner Extension
Bracket

Outer Extension Bracket

RENOGY MTS-TM100 Flat Roof Tilt Mount - Outer Extension
Bracket

L-Foot

RENOGY MTS-TM100 Flat Roof Tilt Mount - L-Foot

L-Joint

RENOGY MTS-TM100 Flat Roof Tilt Mount - L-Joint

Compatibility

The following chart represents the Renogy Modules for which this Tilt Mount works for and is optimized for. Optimization of the module implies that there are more degrees of freedom tilting.

RENOGY MTS-TM100 Flat Roof Tilt Mount - Compatibility

RENOGY.COM

Renogy reserves the right to change the contents of this manual without notice.

US

2775 E Philadelphia St, Ontario, CA 91761, USA

909-287-7111

www.renogy.com

support@renogy.com

JP

https://www.renogy.jp
supportjp@renogy.com

CA

https://ca.renogy.com
supportca@renogy.com

AU

https://au.renogy.com
supportau@renogy.com

UK

https://uk.renogy.com
supportuk@renogy.com

DE

https://de.renogy.com
supportde@renogy.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals