ring Motion Detector 2nd Generation Z-Wave User Guide
- June 6, 2024
- Ring
Table of Contents
- ring Motion Detector 2nd Generation Z-Wave
- Introduction
- Installation & Set Up
- Z-Wave Instructions
- Ring Alarm Motion Detector – Inclusion
- Ring Alarm Motion Detector – Exclusion
- Ring Alarm Motion Detector – Factory Reset
- Z-Wave Command Classes
- Notification Command Class, V8
- Supplier’s Declaration of Conformity – Compliance Information Statement
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ring Motion Detector 2nd Generation Z-Wave
Introduction
Ring Alarm Motion Detector is a wireless sensor for the Ring Alarm system
which provides users the ability to know when there is movement of a person or
similar object within an area. After installing the sensor and setting up the
sensor in the Ring app, monitor and receive notifications motion is detected.
The Ring Alarm Base Station is required to enable Motion Detector features and
functions within the Ring app.
Notes:
- This product can be operated in any Z-Wave™ network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
- SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
Installation & Set Up
Ring Alarm Motion Detector – Basic Setup & Installation In-app Setup
- Ensure your Ring Alarm system is disarmed.
- In the Ring app, tap Set Up a Device and find the Motion Detector in the Security Devices menu.
- Follow the in-app instructions to complete setup.
a. Pull the battery tab (or reinsert the batteries) to trigger setup mode.
b. Tap the button on the front to retry setup mode.
Installation
-
Choose a location for installing your Motion Detector.
a. For best coverage, install the Motion Detector at a height of between 7-8 feet
b. It is recommended to install the Motion Detector on a wall or in a corner looking out onto an area to monitor.
c. Ensure no large objects block the field of view (FOV) of the Motion Detector. -
Ensure the surface where you plan to install your Motion Detector is clean and free from dust or dirt.
-
Using the provided double-sided tape, peel the backing and attach the Motion Detector to the mounting location.
Note
Leave ~ ½ in. of space free on the top side to ensure you can slide open the
case when it’s time to change the batteries.
This product can be operated in any Z-Wave network with other Z-Wave certified
devices from other manufacturers. All mains operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
This is a SmartStart enabled product which can be added into a Z-Wave network
by scanning the
Z-Wave QR Code present on the product with a controller providing SmartStart
inclusion. No further action is required and the SmartStart product will be
added automatically within 10 minutes of being switched on in the network
vicinity. This product can also be operated in any Z-Wave network with other
Z-Wave certified devices from other manufacturers.
Z-Wave Instructions
Z-Wave Device Type: Notification Sensor
Role Type: Listening Sleeping Slave
GENERIC_TYPE_SENSOR_NOTIFICATION (0x07)
SPECIFIC_TYPE_NOTIFICATION_SENSOR (0x01)
Ring Alarm Motion Detector – Inclusion
Adding Ring Alarm Motion Detector to a Z-Wave Network
Ring Alarm Motion Detector can be added via SmartStart or Classic inclusion
mode.
Note
When prompted for the QR Code or PIN, you may find them on the device, on the
box, or on a card inside the box. Keep the device nearby. You’ll be prompted
to pull the battery tab to power on the device and enter setup mode.
SmartStart Inclusion Steps:
- Initiate the add flow for Security Devices in the Ring mobile application – Follow the guided add flow instructions provided in the Ring mobile application.
- When prompted by the mobile application, scan the QR code found on the package of the Motion Detector. The QR code can also be found on the device itself.
- Pull the pull-tab or insert batteries, and the device will go into SmartStart inclusion mode. While in this mode, Motion Detector can be added to a Z-Wave controller that supports SmartStart. When in SmartStart inclusion mode, SmartStart can be restarted by tapping the button on the front of
the device.
Classic Inclusion Steps:
Classic Inclusion should be used if the controller does not support
SmartStart.
- Initiate add flow for Security Devices in the Ring mobile application – Follow the guided add flow instructions provided in the Ring mobile application.
- Select add manually and enter the 5-digit DSK PIN found on the package of the Ring Alarm Motion Detector or the 5-digit DSK PIN found under the QR code on the device.
- After powering on the device, press and hold the button on the front of the device for ~3 seconds. Release the button and the device will enter Classic inclusion mode which implements both classic inclusion with a Node Information Frame, and Network Wide Inclusion. During Classic Inclusion mode, the green LED will blink three times followed by a brief pause, repeatedly. When Classic inclusion times-out, the device will blink alternating red and green a few times.
LED Behabior for Inclusion | Blink Pattern |
---|---|
SmartStart Started | Green LED three times, repeated after a brief pause |
Classic Inclusion Started | Green LED three times, repeated after a brief pause |
Classic Inclusion Timed-Out | Alternate red and green a few times |
Inclusion Successful (Authenticated S2) | Green LED on solid |
Inclusion Not Successful (Self-Destruct) | Red LED on solid |
Ring Alarm Motion Detector – Exclusion
Removing Ring Alarm Motion Detector from a Z-Wave Network
Exclusion Instructions:
- Initiate remove “Ring Alarm Motion Detector” flow in the Ring Alarm mobile application – Select the settings icon from device details page and choose “Remove Device” to remove the device. This will place the controller into Remove or “Z-Wave Exclusion” mode.
- Locate the pinhole reset button on the back of the device in the battery compartment.
- With the controller in Remove (Z-Wave Exclusion) mode, use a paper clip or similar object and tap the pinhole button. The device’s red LED turns on solid to indicate the device was removed from the network.
Ring Alarm Motion Detector – Factory Reset
Factory Default Instructions
- To restore Ring Alarm Motion Detector to factory default settings, locate the pinhole reset button on the device. This is found inside the battery compartment on the back of the device after removing the back bracket.
- Using a paperclip or similar object, insert it into the pinhole, press and hold the button down for 10 seconds.
- The device will rapidly blink green continuously for 10 seconds. After about 10 seconds, when the green blinking stops, release the button. The red LED will turn on solid to indicate the device was removed from the network.
Note
Use this procedure only in the event that the network primary controller is
missing or otherwise inoperable.
Wake-Up Notification
Not applicable. Ring Alarm Motion Detector is a Frequently Listening Receiver
Slave (FLiRS) device and does not support Wake Up Command Class.
Z-Wave Command Classes
Command Class | Version | Required Security Class |
---|---|---|
Association | 2 | Highest granted |
Association Group Information | 3 | Highest granted |
Device Reset Locally | 1 | Highest granted |
Firmware Update Meta Data | 5 | Highest granted |
Indicator | 3 | Highest granted |
Manufacturer Specific | 2 | Highest granted |
Multi-Channel Association | 3 | Highest granted |
Powerlevel | 1 | Highest granted |
Security 2 | 1 | none |
Supervision | 1 | none |
Transport Service | 2 | none |
Version | 3 | Highest granted |
Z-Wave Plus™ Info | 2 | none |
Notification | 8 | Highest granted |
Wake Up | 2 | Highest granted |
Configuration | 4 | Highest granted |
Battery | 2 | Highest granted |
Association Command Class
Group Identifier | Max Nodes | Description |
---|
1 (Lifeline)
|
0x05
| 1. Notification Report
a. See notification CC section for notifications that are sent
2. Battery Report
3. Device Reset Locally Notification
Configuration Command Class
The sensor has the following supported configuration parameters.
Parameter Number| Description| Number of
Bytes
| Default| Min| Max| Format
---|---|---|---|---|---|---
1
| Heartbeats:
This parameter is the number min- utes between heartbeats. Heart- beats are automatic battery reports on a timer after the last event.
|
1
|
70 (0x46)
|
1 (0x01)
|
70 (0x46)
|
0x01
Unsigned
2
| Number of application level retries attempted for messages either not ACKed or messages encapsulated via supervision get that did not receive a report.|
1
|
1 (0x01)
|
0 (0x00)
|
5 (0x05)
|
0x01
Unsigned
3
| Application Level Retry Base Wait Time Period: The number base seconds used in the calculation for sleeping between retry messages.|
1
|
5 (0x05)
|
1 (0x01)
|
60 (0x3C)
|
0x01
Unsigned
4
| This parameter allows a user, via software, to configure the various LED indications on the device.
0 == Don’t show green
1 == Show green after Supervision Report Intrusion (Fault)
2 == Show green after Supervision Report both Intrusion and Intrusion clear
|
1
|
1 (0x01)
|
0 (0x00)
|
2 (0x01)
|
enum
5
| The number of milliseconds waiting for a Supervisory Report response to a Supervisory Get encapsulated command from the sensor before attempting a retry.|
2
|
1500 (0x5DC)
|
500 (0x1F4)
|
5000 (0x1388)
|
0x01
Unsigned
6| Occupancy Clear Delay (seconds)| 2| 0x00| 0x00| 0xFF| 0x01
Unsigned
7| Intrusion Clear Delay (seconds)| 1| 0x05| 0x00| 0xFF| 0x01
Unsigned
8| Standard Clear Delay (seconds)| 1| 0x0A| 0x00| 0xFF| 0x01
Unsigned
9| Motion Detection Mode| 1| 0x03| 0x00| 0x04| 0x01
Unsigned
10| Any motion Threshold| 1| 0x80| 0x00| 0xFF| 0x01
Unsigned
11| Lighting Enabled| 1| 0x00| 0x00| 0x01| 0x01
Unsigned
12| Lighting Delay| 1| 0x02| 0x00| 0x3C| 0x01
Unsigned
Notification Command Class, V8
Sensor Condition | Command Class and Value | Association Group |
---|
Motion Detected
| Notification Report
Type: Home Security 0x07 State: Intrusion 0x08
|
1 (Lifeline)
Motion Cleared
| Notification Report
Type: Home Security 0x07
State: Previous Events Cleared 0x00 Event parameter: 0x08
|
1 (Lifeline)
Sensor Case Removed
| Notification Report
Type: Home Security 0x07
State: Tampering Product Covering Removed 0x03
|
1 (Lifeline)
Sensor Case Fastened
| Notification Report
Type: Home Security 0x07
State: Previous Events Cleared 0x00 Event Parameter: 0x03
|
1 (Lifeline)
Comm Test Button Pressed
| Notification Report Type: System 0x09 Event: Heartbeat 0x05|
1 (Lifeline)
Watchdog Notification
| Notification Report Type: System 0x09
State Value: 0x04 System Software Failure State Parameter Value = 0x55
|
Software Fault (Ring)
| Notification Report Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xAA (Ring Value for Soft Fault)
|
1 (Lifeline)
Software Fault (SDK)
| Notification Report Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xA9 (SDK Value for Soft Fault)
|
1 (Lifeline)
Pin Reset (soft reset)
| Notification Report Type: System 0x09
State Value: 0x04 System Software Failure State Parameter Value = 0xAB
|
1 (Lifeline)
Software Reset (Not triggered by failure)
| Notification Report Type: System 0x09
State Value: 0x04 System Software Failure State Parameter Value = 0xAC
|
1 (Lifeline)
Power On
| Notification Report
Type: 0x08 Power Management
Event Parameter: 0x01 Power has been applied
|
1 (Lifeline)
Brownout
| Notification Report
Type: 0x08 Power Management Event: 0x05 Voltage Drop/Drift
|
1 (Lifeline)
Dropped Frame
| Notification Report
Type: 0x08 Power Management
Event Parameter: 0x01 Power has been applied
|
1 (Lifeline)
Co-Processor Watchdog
| Notification Report Type: System 0x09
State Value: 0x04 System Software Failure State Parameter Value = 0xAE
|
1 (Lifeline)
Failed to retrieve
FW version of Co-Processor
| Notification Report Type: System 0x09
State Value: 0x04 System Software Failure State Parameter Value = 0xAF
|
1 (Lifeline)
Supplier’s Declaration of Conformity – Compliance Information Statement
Unique Identifier: Ring Contact Sensor
Responsible Party and Party issuing Supplier’s Declaration of Conformity
Ring LLC dba Ring
1523 26th Street
Santa Monica, CA 90404 U.S.A.
www.ring.com / Legal@ring.com
FCC Compliance Statement (for products subject to Part 15)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Innovation, Science and Economic Development Canada (ISED) Compliance
This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element shall be installed such that a minimum separation distance of 20 cm is maintained from the general population.
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
CAUTION: To reduce the risk of electrical shock, DO NOT open the unit. There are no user serviceable parts inside the unit. Refer to customer support for any repairs.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>