DMP 263LTE-FN Cellular Communicator User Guide

June 6, 2024
DMP

263LTE-FN CELLULAR
COMMUNICATOR
Installation Guide

DMP 263LTE FN Cellular Communicator-

DESCRIPTION

The 263LTE-FN Cellular Communicator provides a fully-supervised alarm communication path over a reserved AT&T network. The module installs on the panel inside the enclosure and is powered by the panel so no additional enclosure, power supply, or battery backup is needed. The 263LTE-FN is FirstNet Ready™.

Compatibility

  • XR150/XR550 Series panels with Version 202 or higher

What is Included

  • 263LTE-FN Cellular Communicator
  • 383 antenna
  • PCB standoff
  • Hardware pack

INSTALL THE 263LTE-FN

Caution: Touch grounded metal to discharge static before handling the panel.
XR150/XR550 Series Panels

  1. Open the panel enclosure, set the reset jumper, and remove power from the panel.
  2. Insert the included standoff into the XR150/XR550 Series panel standoff hole.
  3. Secure the 263LTE-FN on the 12-pin cell module connector. See Figure 3.
  4. Align the 263LTE-FN standoff hole with the standoff already placed in the panel and snap it into place.

DMP 263LTE FN Cellular Communicator-Panels

CONNECT THE ANTENNA

Be sure to only use the included 383 antennae when installing the 263LTE-FN.
XR150/XR550 Series Panel

  1. Attach one end of the included 381-2 coax cable to the 263LTE-FN SMA connector.
  2. Position one washer onto the other end of the coax cable and push the threaded end through the antenna knockout hole.
  3. Position the second washer onto the threaded end that extends through the antenna knockout hole and secures the nut.
  4. Attach the included LTE antenna to the coax cable SMA connector. See Figure 5.

CONNECT THE ANTENNA

DMP 263LTE FN Cellular Communicator-CONNECT THE
ANTENNA

ACTIVATE THE 263LTE-FN

Cellular service is required before you can use the 263LTE-FN for signal transmission. The 263LTE-FN comes ready for activation with SecureCom™
Wireless, LLC. Use Remote Link™, the Dealer Admin™site (DMPDealerAdmin.com), the Tech APP™, or call DMP CustomerService (1-866-266-2826) to activate the 263LTE-FN.

Dealer Admin Activation

  1. Navigate to the Dealer Admin site (DMPDealerAdmin.com).
  2. Click Customers in the right-side menu and select a customer.
  3. Click Add System.
  4. Enter a System   Name.
  5. Select either Cellular or EASYconnect + Cell Backup in the Connection Type field.
  6. Enter the SIM number found on the 263LTE-FN label and click Get Status.
  7. Enter the Account Number.
  8. Select a Rate Plan for the 263LTE-FN.
  9. Click Activate Cellular Device.

Tech APP Activation

  1. Navigate to the Tech APP.
  2. Tap Find a Customer then search for a customer.
  3. Tap Add a System.
  4. Enter a System Name.
  5. Scan or enter the Serial   #.
  6. Select either Cellular or EASYconnect + Cell Backup in the Connection Type field.
  7. Enter the Account Number.
  8. Enter the SIM Number found on the 263LTE-FN label then tap Get SIM Status.
  9. Select a Rate Plan for the 263LTE-FN.
  10. Tap Activate Cellular Device.

Remote Link Activation

  1. Navigate to Remote Link and select a panel.
  2. Select Program in the top menu and select Communications from the dropdown menu.
  3. Select Cellular Network as the Communication Type and click Activate.
  4. Select SIM as the SIM Type.
  5. Enter the SIM number found on the 263LTE-FN label and press the Tab key.
  6. Select a Rate Plan for the 263LTE-FN and click Activate.

TEST THE 263LTE-FN

The panel provides a diagnostic function to test the communication integrity and cellular signal strength of the 263LTE-FN to the nearest tower for the cellular carrier. To use the diagnostic function, reset the panel, enter 2313 (DIAG), and press CMD.

Communication Status
This option tests the individual components of cellular or wireless network communication.

  1. Select CELL STATUS from the Diagnostic menu. Possible test results are shown in Table 1.
  2. Select YES to continue through the remaining component tests or select NO to stop testing and return to CELL STATUS.
Confirmed Faulty
MODEM OPERATING NO MODEM FOUND
IDENTIFIED NO SIM CARD
TOWER DETECTED NO TOWER
REGISTERED NOT REGISTERED
CONNECT SUCCESS CONNECT ERROR

NOT ACTIVATED
CELL PATH GOOD| NO ACK RECEIVED

Table 1: Cell Status Test Results

FCC INFORMATION

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.
    The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from all persons. It must not be located or operated in conjunction with any other antenna or transmitter. Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However,  there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Industry Canada Information

This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device.

This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm) to maintain compliance with the General Population limits.

263LTE-FN CELLULAR
COMMUNICATOR

Specifications

Primary Power 12 VDC from the panel
Current Draw
Standby 6 mA
Alarm 7 mA

DMP 263LTE FN Cellular Communicator-CELLULAR

Ordering Information
263LTE-FN Cellular Communicator for AT&T LTE

Accessories
381-2 18” Coax Cable
381-12 12’ Coax Extension
381-25 25’ Coax Extension
383 Dual Band Antenna (included)
386 Antenna Mounting Bracket

Compatibility
XR150/XR550 Series Version 202 or higher

Certifications

FCC Part 15: XMR201909EC25AFX
Industry Canada: 10224A-201909EC25AFX

Underwriters Laboratory (UL) Listed

  • ANSI/UL 294 Access Control System Units
  • ANSI/UL 636 Holdup Alarm Units and System Accessory
  • ANSI/UL 1023 Household Burglar
  • ANSI/UL 1076 Proprietary Burglar
  • ANSI/UL 1610 Central Station Burglar
  • ANSI/UL 1635 Digital Burglar
  • ANSI/UL 985 Household Fire Warning
  • ANSI/UL 864 Fire Protective Signaling 9th Edition.
  • ANSI/UL 365 Police Sta. Connected Burg Alarm Units & Systems
  • ANSI/UL 609 Local Burg Alarm Units & Systems

Underwriters Laboratory of Canada (ULC) Listed

  • ULC S304 Central Station Burglar
  • ULC – Subject – C1023 Household Burglar
  • ULC/ORD – C1076 Proprietary Burglar
  • ULC – S545 Household Fire
  • ULC – S559 Equipment for Fire Receiving Centers and Systems

263LTE SERIES INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS

Designed, engineered, and manufactured in Springfield, Missouri using the U.S. and global components.
© 2020 Digital Monitoring Products,
Inc.
LT-2184 1.01 20433
INTRUSION • FIRE • ACCESS • NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803-8877
888.436.7832 | DMP.com

Documents / Resources

| DMP 263LTE-FN Cellular Communicator [pdf] User Guide
DMP, 263LTE-FN, Cellular, Communicator
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>