Panasonic S-200PE3E5B High Static Pressure Ducted Instruction Manual
- June 4, 2024
- Panasonic
Table of Contents
- Panasonic S-200PE3E5B High Static Pressure Ducted [](https://manuals.plus
- Product Information
- Safety Precautions
- WARNING
- Installation
- Operation Preparation
- INDOOR UNIT[](https://manuals.plus/wp-content/uploads/2022/08/Panasonic-S
- [Optional
- Operation
- Maintenance
- Troubleshooting
- Before Requesting Services
- Specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Panasonic S-200PE3E5B High Static Pressure Ducted [](https://manuals.plus
/wp-content/uploads/2022/08/Panasonic-S-200PE3E5B-High-Static-Pressure-Ducted- PRODUCT.jpg)
Connectable outdoor unit lineup This booklet is the operating instructions for indoor unit. Regarding the outdoor unit, see the operating instructions supplied with the outdoor unit.
WARNING
This symbol shows that this equipment uses a flammable refrigerant. If the
refrigerant is leaked, together with an external ignition source, there is a
possibility of ignition.
CAUTION
This symbol shows that service personnel should be handling this equipment
with reference to the Technical Manual.
CAUTION
This symbol shows that there is information included in the Operating
Instructions and/or Installation Instructions.
Product Information
If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate.Refer to the Installation Instructions attached to the outdoor unit.
Safety Precautions
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
- Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.
- This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions.
WARNING
Confirm to authorized dealer or specialist on usage of specified
refrigerant type. Using of refrigerant other than the specified type may cause
product damage, burst and injury etc.This air conditioner has no ventilator
for intaking fresh air from outdoors. You must open doors or windows
frequently when you use gas or oil heating appliances in the same room, which
consume a lot of oxygen from the air. Otherwise there is a risk of suffocation
in an extreme case.Never use or store gasoline or other flammable vapor or
liquid near the air conditioner — it is very dangerous.Do not use this
appliance in a potentially explosive atmosphere.Never touch the unit with wet
hands.Do not insert your fingers or other objects into the air conditioner
indoor or outdoor unit, rotating parts may cause injury.
- If the refrigerant comes in contact with a flame, it produces a toxic gas.
- For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing.
- Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency.
- Dispose of according to national and/or local legislation.
- This product must not be modified or disassembled under any circumstances.
- Modified or disassembled unit may cause fire, electric shock or injury.
- Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning.
- In case of malfunction of this appliance, do not repair by yourself. Contact the sales dealer or service dealer for a repair and disposal.
- Provide a power outlet to be used exclusively for each unit, and a power supply disconnect, Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) for overcurrent protection should be provided in the exclusive line.
- Provide a power outlet exclusively for each unit, and full disconnection means having a contact separation in all poles must be incorporated in the fixed wiring in accordance with the wiring rules.
- To prevent possible hazards from insulation failure, the unit must be grounded.
- Do not use modified cord, joint cord, extension cord or unspecified cord to prevent overheating and fire.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Be aware that refrigerants may not contain an odour.
- An unventilated area wherethe appliance using flammable refrigerants is installed shall be so constructed that should any refrigerant leak, it will not stagnate so as to create a fire or explosion hazard.
- The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- After the unit is installed, never fail to ask the installer for the floor space of the room where the unit is installed and the refrigerant charge amount.In case the unit or the room divider is changed, never fail to consult the sales dealer or service dealer.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- Do not pierce or burn.
- In cases that require mechanical ventilation, ventilation openings shall be kept clear of obstruction.
WARNING
-
The appliance shall be storedin a room without continuously operating open flames (for example: an operating gas appliance) and ignition sources (for example: an operating electric heater).
-
Stop using the product when any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker.(Risk of smoke/fire/electric shock)
Examples of abnormality/failure:- The ELCB trips frequently.
- The product sometimes does not start when turned on.
- The power is sometimes disconnected when the cord is moved.
- The body is deformed or abnormally hot.
- Water leaks from the indoor unit.
- Power cord or plug becomes abnormally hot.
- Fan speed cannot be controlled. The unit stops running immediately even if it is switched on for operation.
- Contact immediately your local dealer for maintenance/repair.
- Do not sit or step on the unit. You may fall down accidentally.
CAUTION
This appliance is intended to be used by expert or trained users in shops,
in light industry and on farms, or for commercial use by lay persons.This
appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision.Keep the fire alarm and the air outlet at
least 1.5m away from the unit.Do not cool or heat the room too much if babies
or invalids are present.Do not turn the air conditioner on and off from the
power mains switch. Use the ON/OFF operation button.Do not stick anything into
the air outlet of the outdoor unit. This is dangerous because the fan is
rotating at high speed.Do not touch the air inlet or the sharp aluminum fins
of the outdoor unit. You may get injured.Do not stick any object into the FAN
CASE. You may be injured and the unit may be damaged.
NOTICE
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers after a few minutes.
- The English text is the original instructions. Other languages are translation of the original instructions.
Installation
- This air conditioner must be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.
- Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.
- Locations where smoke or combustible gas exists.
- Also locations of extremely high temperature such as a greenhouse.
- Locations where excessively high heat-generating objects are placed.
Wiring
-
All wiring must conform to the local electrical codes. (Consult your dealer or a qualified electrician for details.) z Each unit must be properly grounded with a ground (or
earth) wire or through the supply wiring. -
Wiring must be done by a qualified electrician.
Operation Preparation
Turn the power mains on 5 hours before the start of operation. (For warm- up)Leave the power mains ON for continuous use.
NOTE
Pull off the power plug from a receptacle, or switch off the breaker, or
switch off the power disconnecting mean to isolate the air conditioner from
the main power supply when not in use for a long time.Information for Users on
Collection and Disposal of Old Equipment and Used BatteriesThese symbols on
the products, packaging, and/or accompanying documents mean that used
electrical and electronic products and batteries should not be mixed with
general household waste. For proper treatment, recovery and recycling of old
products and used batteries, please take them to applicable collection points,
in accordance with your national legislation and the Directives 2002/96/EC and
2006/66/EC. By disposing of these products and batteries correctly, you will
help to save valuable resources and prevent any potential negative effects on
human health and the environment which could otherwise arise from
inappropriate waste handling. For more information about collection and
recycling of old products and batteries, please contact your local
municipality, your waste disposal service or the point of sale where you
purchased the items.
Penalties may be applicable for incorrect disposal of this waste, in
accordance with national legislation. For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact
your dealer or supplier for further information. These symbols are only valid
in the European Union. If you wish to discard these items, please contact your
local authorities or dealer and ask for the correct method of disposal.Note
for the battery symbol (bottom two symbol examples): This symbol might be used
in combination with a chemical symbol. In this case it complies with the
requirement set by the Directive for the chemical involved.
INDOOR UNIT[](https://manuals.plus/wp-content/uploads/2022/08/Panasonic-S
-200PE3E5B-High-Static-Pressure-Ducted-FIG-1.jpg)
Optional[
](https://manuals.plus/wp- content/uploads/2022/08/Panasonic-S-200PE3E5B-High-Static-Pressure-Ducted- FIG-2.jpg)
Read the Operating Instructions included with the Remote Controller.
Operation
For details, refer to the Operating Instructions attached to the optional Remote Controller.
Maintenance
- For safety, be sure to turn the air conditioner off and disconnect the power before cleaning. (Otherwise, electric shock or injury may result because the fan is rotating at high speed.)
- Do not pour water on the indoor unit. (This may damage the internal components and cause an electric shock hazard.)
- ‘The internal coil and other components of the indoor and outdoor unit must be cleaned periodically.
- Consult your dealer or service center.
CAUTION
- Never use solvents or harsh chemicals. Also, do not wipe plastic parts using very hot water. (This may cause deformation or change in colour.)
- Some metal edges and fins are sharp. Be careful when you clean those parts. (Injury may result.)
- Use a firm stool or ladder when cleaning an indoor unit
Troubleshooting
Noise
|
Sound like streaming water is heard during operation or after operation.
---|---
Cracking noise is heard during operation or when operation stops.
Discharged air smells during operation.
Dewdrops accumulate near the air outlet during cooling operation.
Fog occurs during cooling operation.
Fog occurs during heating operation.
The fan is rotating for a while even though operation stops.
Dust is discharged.
• Sound of refrigerant liquid flowing inside unit
• Sound of drainage water through drain pipe
• Sound due to temperature changes of parts
• Indoor odor components, cigarette odor and cosmetic odor accumulated in the
air conditioner and its air is discharged.
• The unit inside is dirty. (Contact your dealer.)
• Internal moisture is cooled by cool wind and accumulates as dewdrops.
• If the air conditioner has been installed at places such as restaurants where large amounts of oil mist exist, cleaning is necessary because the unit inside (heat exchanger) is dirty. (Contact your dealer.)
• Defrost operation is in process.
• Fan rotation makes operation smooth.
• The fan may rotate to dry the heat exchanger depending on the setting.
• Dust accumulated inside the indoor unit is discharged.
Before Requesting Services
Symptom| Cause| Action| |
---|---|---|---|---
The air conditioner does not operate although the power is turned on.|
Power failure or after power failure| Press the power ON/OFF button on the
remote controller.|
The operation (power) button is turned off.
| • If the breaker is turned off, turn the power on.
• If the breaker has been tripped, consult your dealer without turning it on.
|
E NGLISH
|
Fuse blow out.| Contact your dealer.|
Poor cooling or heating performance
| The air intake or air outlet of indoor and outdoor units is clogged with
dust.| Remove the dust.|
|
Improper temperature settings|
See “Tips for Energy Saving”. (P.5)
|
The room is exposed to direct sunlight in cooling mode.|
Doors or windows are open.|
Too many heat sources in the room in cooling mode.| Use minimum heat sources
and in a short time.|
Too many people in the room in cooling mode.| Lower the temperature setting or
change to “Medium” or “High”.|
If your air conditioner does not work properly even after checking each item of
“Before Requesting Services” and “Troubleshooting”
Stop the operation immediately and turn the power off. Then contact your
dealer and report the serial number and symptom. You also report if the
inspection mark and the letters E, F, H, L, P in combination with numbers
appear on the LCD of the remote controller.Never repair the air conditioner by
yourself since it is very dangerous for you to do so.
Specifications
Model Name | S-200PE3E5B | S-250PE3E5B |
---|---|---|
Power Source | 220 – 230 – 240 V~ 50 Hz |
Cooling capacity
| kW| 19.5| 23.2
BTU/h| 66,500| 79,200
| Sensible| kW| 16.2| 19.0
Latent| kW| 3.3| 4.2
Heating capacity
| kW| 22.4| 28.0
BTU/h| 76,400| 95,500
Cooling electric power input| kW| 0.610| 0.830
Heating electric power input| kW| 0.610| 0.830
Sound Pressure level
| High| dB(A)| 46| 47
Medium| dB(A)| 44| 45
Low| dB(A)| 41| 42
Sound Power level
| High| dB(A)| 78| 79
Medium| dB(A)| 76| 77
Low| dB(A)| 73| 74
Unit Dimensions (H×W×D)| mm| 486×1,456×916| 486×1,456×916
Net weight| kg| 86| 88