KEESON MCB220 Control Box Function Instructions
Electrical Configuration Diagram
Function Picture
Process of Test
Head Motor
Connect to head actuator, control by remote single:
Click head up button on the remote, head actuator moves out, stop when
released;
Click head down button,head actuator moves in, stop when released;
This function takes effect only by pressing the corresponding button on the
remote.
Foot Motor
Connect to foot actuator, control by remote single:
Click foot up button,foot actuator moves out,stop when released;
Click foot down button,foot actuator moves in,stop when released;
This function takes effect only by pressing the corresponding button on the
remote.
Sync Port
Connect with the same other Control box or Other accessories;
Power LED & Pairing LED
Power supply for control box, PAIRING LED of control box is blue, POWER LED is green.
Power
Connect to the 29V DC;
RESET button
Press and hold the RESET button,the Head, Foot actuators will moves to lower position.
Pair Function
Once power on ,pairing LED turns on,the control box enters into mode of code
paring;
Press and hold the paring LED of Remote, the backlight of paring LED flashes,
the backlight of remote flashes, the remote enters into mode of code paring;
The backlight of paring LED of remote stops flashing, and the paring led of
control box turns off, it indicates that the code paring is successful;
If fails, repeat all the processes above;
FLAT Function
Press and release the FLAT button on remote,the head and foot actuators moves to lower position (when the actuator is free, can turn off the vibration motor and turn off the indicator light when press once ),stop when press any buton;
This function takes effect only by pressing the corresponding button on the remote.
ZERO G Position Function
Press and release ZERO G button on remote,the head and foot actuator moves to
preset memory position,stop when press any button;
This function takes effect only by pressing the corresponding button on the
remote.
FCC warning
Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC/IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
ISED Warning:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: