MC232F Function instruction
Electrical configuration diagram:
Remote Picture
Process of test
1.1. HEAD port
Connect to head actuator,control by remote single:
Click head up button on the remote, head actuator moves out, stop when
released;
Click head down button,head actuator moves in, stop when released;
This function takes effect only by pressing the corresponding button on the
remote.
1.2. FOOT port
Connect to foot actuator,control by remote single:
Click foot up button,foot actuator moves out ,stop when released;
Click foot down button,foot actuator moves in ,stop when released;
This function takes effect only by pressing the corresponding button on the
remote.
1.3. LUMBAR port
Connect to lumbar actuator,control by remote single:
Click lumbar up button ,lumbar actuator moves out,stop when released;
Click lumbar down button ,lumbar actuator moves in ,stop when released;
This function takes effect only by pressing the corresponding button on the
remote.
1.4. FOOT VIBRATION
Connect to foot massage,control by remote:
Click foot massage + button,foot massage strengthens by one level;
Click foot massage – button,foot massage weakenby one level;
This function takes effect only by pressing the corresponding button on the
remote.
1.5. HEAD VIBRATION
Connect to head massage,control by remote:
Click head massage + button,head massage strengthens by one level;
Click head massage – button,head massage weakenby one level;
This function takes effect only by pressing the corresponding button on the
remote.
1.6. MULTIFUNCTION port
Connect with the same other Control box or Other accessories;
1.7. Power LED & PAIRING LED
Power supply for control box, LED of control box flashes for 10 seconds,and
then turns on 。
1.8. Power
Connect to the 29V DC;
1.9. Pair Function
Power on ,the control box enters into mode of code paring ;
Press and hold the paring LED of Remote, the backlight of paring LED flashes,
the backlight of remote flashes, the remote enters into mode of code paring;
The backlight of paring LED of remote stops flashing, and the paring led of
control box turns off, it indicates that the code paring is successful;
If fails, repeat all the processes above;
1.10. Test for underbed light
Click button of underbed light, turns on( or turns off ) the underbed light,
switch the status once when click once;
This function takes effect only by pressing the corresponding button on the
remote.
1.11. FLAT function
Press and release the FLAT button on remote,the head and foot actuators moves
to lower position(when the actuator is free, can turn off the vibration motor
and turn off the indicator light when press once ),stop when press any buton ;
This function takes effect only by pressing the corresponding button on the
remote.
1.12. ZERO G position function
Press and release ZERO G button on remote,the head and foot actuator moves to
preset memory position ,stop when press any button ;
This function takes effect only by pressing the corresponding button on the
remote.
1.13. Ⅰ position function
Press and release Ⅰ on remote,the head and foot actuator moves to preset
memory position, stop when press any button;
This function takes effect only by pressing the corresponding button on the
remote.
1.14. Ⅱ position function
Press and release Ⅱ on remote ,the head and foot actuator moves to preset
memory position, stop when press any button;
This function takes effect only by pressing the corresponding button on the
remote.
FCC warning
Please take attention that changes or modification not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
This equipment complies with FCC/IC RSS-102 radiation exposure limits set
forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
IC RSS warning
This device complies with Industry Canada licence-exempt RSS standard (s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,including
interference that may cause undesired operation of the device.
ISED RSS Warning:
This device complies with Innovation,Science and Economic Development Canada
licenceexempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
This equipment complies with FCC/IC RSS-102 radiation exposure limits set
forth for an uncontrolled environment. This equipment should be installed and
operated with minimum distance 20cm between the radiator & your body.
| Issue department :Bedding Division| Date :| 5/3/2017
---|---|---|---