Intended Use

The BioFire® COVID-19 Test is a nested multiplexed real-time RT-PCR test intended for the qualitative detection of nucleic acid from SARS-CoV-2 in nasopharyngeal swabs in transport media from individuals suspected of COVID-19 by their healthcare provider. Please see www.fda.gov/medical-devices /emergency-situations-medical-devices/emergency-use- authorizations#covid19ivd for the Instructions for Use.
Storage Instructions
Store at 15 – 30ºC. Refer to the BioFire® COVID-19 Test Instructions for Use before opening and preparing pouch for use.

Procedure / Interpretation / Limitations
Users should refer to the BioFire® COVID-19 Test Instructions for Use available on the BioFire Defense Website: www.biofiredefense.com/covid- 19test
Questions / Support
If you have questions or need additional support, please contact BioFire Defense Technical Support at support@biofiredefense.com

Package Contents

BIOFIRE 423745 Pouch Loading Station with FilmArray System fig
1

Use clean gloves and other Personal Protective Equipment (PPE) when performing this procedure.

Step 1: Prepare Pouch

  1. 1. Insert pouch into Pouch Loading Station.
  2.  Place Sample Injection Vial into red well.
  3.  Place Hydration Injection Vial into blue well.BIOFIRE 423745 Pouch Loading Station with FilmArray System fig 2

Step 2: Hydrate Pouch

  1. Unscrew Hydration Injection Vial from cover.
  2. Remove Hydration Injection Vial, leaving blue plastic cover in Pouch Loading Station.
  3. Insert Hydration Injection Vial into pouch hydration port.
  4. Push down to puncture seal and wait as Hydration Solution is drawn into the pouch.BIOFIRE 423745 Pouch Loading Station with FilmArray System fig 2

NOTE: Verify the pouch has been hydrated.

Step 3: Prepare Sample Mix

  1. Use the transfer pipette to draw specimen in transport media to the 3rd line. Add specimen to Sample Injection Vial.BIOFIRE 423745 Pouch Loading Station with FilmArray System fig 4
  2. Hold Sample Buffer Tube tip facing up and firmly pinch at textured plastic tab on side of tube until seal snaps. NOTE: Do not touch tube tip.
  3. Dispense Sample Buffer into Sample Injection Vial using a slow, forceful squeeze followed by a second squeeze. BIOFIRE 423745 Pouch Loading Station with FilmArray System fig 4 NOTE: Avoid generating excessive foam.
  4. Tightly close the lid on the Sample Injection Vial and invert it 3 times, return it to the red well of Pouch Loading Station.BIOFIRE 423745 Pouch Loading Station with FilmArray System fig 7

Step 4: Load Sample Mix

  1. Unscrew Sample Injection Vial from red plastic cover.

  2. Wait for 5 seconds, then lift Sample Injection Vial, leaving red plastic cover in Pouch Loading Station.
    BIOFIRE 423745 Pouch Loading Station with FilmArray System fig
8
    NOTE : Waiting five seconds decreases the contamination risk.

  3. Insert Sample Injection Vial into pouch sample port.

  4. Push down to puncture seal and wait as Sample Mix is drawn into the pouch.

NOTE : Verify the sample has been loaded.

Step 5: Run Pouch

  1. Discard the Sample Injection Vial and the Hydration Injection Vial in a biohazard sharps container.
  2. Follow instructions on the computer for starting a test. ****

Review Results

Run Summary – Displays information about the sample and a summary of the Internal Controls and test results.

Internal Controls:

  • If ‘Passed’, results are valid.

  • If ‘Failed’ or ‘Invalid’, RETEST SAMPLE and refer to Instructions for Use.

  • BIOFIRE 423745 Pouch Loading Station with FilmArray System fig 9BIOFIRE 423745 Pouch Loading Station with FilmArray System fig 10

Test Interpretation:

  • If ‘Detected’, or ‘Not Detected’, report the results.(Figure 1)BIOFIRE 423745 Pouch Loading Station with FilmArray System fig 9
  • If ‘Equivocal’, RETEST SAMPLE and refer to Instructions for Use. (Figure 2)BIOFIRE 423745 Pouch Loading Station with FilmArray System fig 12

Result Summary – Displays test interpretation (Top Line) with detailed assay results.
Run Details – Displays information about the pouch, protocol, run status, operator, serial number, instrument, and lot number.

Run Status:

  • If ‘Completed’, run is complete.
  • If ‘Incomplete’, ‘Aborted’, or any other error message, RETEST SAMPLE and refer to Instructions for Use.\

NOTE : Refer to Instructions for Use for reporting information.
If repeated error messages are obtained, contact BioFire Defense Technical Support.

Conditions of Authorization
The BioFire COVID-19 Test has not been FDA cleared or approved but has been authorized for emergency use by FDA under a EUA for use by authorized laboratories.
The BioFire COVID-19 Test has been authorized only for the detection of nucleic acid from SARS-CoV-2, not for any other viruses or pathogens.

The emergency use of the BioFire COVID-19 Test is only authorized for the duration of the declaration that circumstances exist justifying the authorization of emergency use of in vitro diagnostics for the detection and/or diagnosis of COVID-19 under Section 564(b)(1) of the Federal Food, Drug and Cosmetic Act, 21 U.S.C. § 360bbb-3(b)(1), unless the declaration is terminated or authorization is revoked sooner

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals