Prorenfort PRO-E-7124AB Synchronizable LED Warning Light Bar Instruction Manual
- June 1, 2024
- Prorenfort
Table of Contents
Prorenfort PRO-E-7124AB Synchronizable LED Warning Light Bar
Specifications
- Input Voltage: +12/24 VDC
- Power Consumption: Varies
- Current Rating: 5 Amp Fuse (ATM05)
- Colors: Colour #1 (Amber), Colour #2 (Blue)
- Patterns: Multiple flash patterns available
- Dimming Function: Yes, optional
- Synchronization: Yes
- Warranty: Void if the lamp is disassembled or wires are cut
Product Usage Instructions
Pattern Selection
- Connect the Blue wire to the Power Wires as follows.
- Briefly connect for less than 1 second to change the pattern.
- Hold for 5 seconds to set the DEFAULT pattern (#1).
Flash Patterns
- #1 – Blue Module synched w/ Blue Rotating
- #2 – Random
- #3 – Single Flash [ SAE Class 1 ]
- #4 – Quad Flash [ SAE Class 1 ]
Synchronizing
Ensure all E-71 lamps are set to the same pattern before connecting synchronization wires.
Suggested Switch Connection
For the dimming function, connect as per the provided wiring information. Otherwise, this connection can be skipped.
FAQ
Q: What should I do if I need to change the flash pattern?
A: Briefly connect the Pattern Selection Wire to the Power Wires for less than 1 second to change the pattern. Hold for 5 seconds to set the DEFAULT pattern (#1).
Q: Can I connect synchronization wires before setting all lamps to the same pattern?
A: No, ensure all E-71 lamps are separately set to the same pattern before connecting synchronization wires.
Wiring Information
Function | Wire Colour | Connect To |
---|---|---|
Activate Colour #1 (Amber) | Red | +12/24 VDC (Power) |
Activate Colour #2 (Blue) | Violet | +12/24 VDC (Power) |
Ground | Black | – Ground |
Pattern Selection | Blue | +12/24 VDC (Power) |
Synchronization | Yellow | Synchronization Wire from other E-71 Unit |
Dimming | White | +12/24 VDC (Power) |
The light should be fused with a 5 Amp Fuse (ATM05 sold separately)
-
Pattern Selection
-
Briefly Connect Pattern Selection Wire (Blue wire) to Power Wires:
-
Less than 1 second for the pattern change
Hold for 5 seconds for the DEFAULT pattern (#1) -
Flash Patterns
-
Blue Module synched w/ Blue Rotating
-
Random
-
Single Flash [ SAE Class 1 ]
-
Quad Flash [ SAE Class 1 ]
-
-
Synchronizing
- Do not connect synchronization wires until all E-71 lamps have been separately set to the same pattern. Once all lamps are set to the same pattern, connect all synchronization wires.
-
Suggested Switch Connection
- (switches sold separately)
Operation
Switch # | Lamp Function |
---|---|
Switch 1 | Colour 1 |
Switch 2 | Colour 2 |
Switch 1 & 2 | Dual Colour Mode |
Switch 3 | Pattern Selection |
Switch 4 | Dimming Function (optional) |
NOTE: Disassembling the lamp or cutting the wires voids the warranty