BROAN 1103434 Overture Wall Control User Manual

June 6, 2024
Broan

broan logo

BROAN 1103434 Overture Wall Control

BROAN 1103434 Overture Wall Control

INCLUDED

Wall Control Part No. 1103434
User Manual
Quick Start Guide
Note: Wall plate not included – Use Broan Part No. S97012925 (or equivalent)

CONTROL SPECIFICATIONS

  • cULus Listed
  • 120 VAC 60 Hz Line Power
  • Maximum load ½ HP Motor, 15A Resistive, 15A Inductive, 3A Incandescent, 0.6A Electronic Ballast
  • When used in combination with fan/light fixtures that are switched together, the device is rated for the following lamps: 360W Incandescent, 72W LED, or 72W CFL
  • Limits the maximum current to 15 Amps for each output and for the entire output.
  • For Control of Electronic Ballast, CFLs, LED and LED lamps or the equivalent
  • Typical Wire Sizes: 12AWG (MAX) or 14AWG solid copper wire rated for at least 90°C
  • Operating temperature: 32-95°F (0-35°C)
  • Purpose of Control: Operating Control
  • Rated impulse voltage: 2500 V

SAFETY

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  1. Before installing the wall control, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. CAUTION: Risk of Electric Shock – More than one disconnect switch may be required to de-energize the equipment before servicing.
  2. All electrical work must be done in accordance with local codes, ordinances, or National Electrical Code, as applicable, including fire-rated construction codes and standards. FOR SAFETY, THIS PRODUCT MUST BE GROUNDED. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified electrician.
  3. Use copper wire only.
  4. WARNING: This device shall not be used in combination with a wall switch controlling a receptacle.
  5. Install only in a UL Listed junction box sized 2.0 x 3.0 x 3.0 in. (50.8 x 76.2 x 76.2 mm) or larger, with a minimum volume of 18.0 in3 (295 CM3) for 14AWG wiring and 20.0 in3 (328 CM3) for 12AWG wiring.
  6. This control requires a neutral wire for operation.
  7. When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.
  8. To prevent serious injury from electrical shock or damage to electrical components – DO NOT WIRE HOT!
  9. The automatic operation feature is Type 1.C action, according to UL 60730-1.
  10. The enclosure protection rating is IP30.
  11. The product is Pollution Degree 2, which is intended to be used in a household environment or similar.
  12. The devices are not intended for use in locations where the temperature may be less than actual room conditions, such as unheated warehouses or garages.
  13. Avoid water and wet locations. Keep the device away from water, fire, excessive humidity, or hot environments.
  14. Do not use the device where wireless devices are not allowed.
  15. Do not attempt to disassemble, repair, or modify the device. Don’t disassemble the product, or make repairs yourself. You run the risk of electric shock and voiding the limited warranty. If you need service, please contact us.
  16. Note: When power is applied, the Wall Control 1103434 may require approximately 30 seconds to boot up and be ready to function.
  17. Please read and follow the above safety information when operating the device. We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your own risk.

Warranty is void if miswired.

INSTALLATION

NOTE: This control requires a 120 VAC source (hot and neutral) in the switch box to operate the wall control.

  1. Turn off the power and lockout the service panel before wiring the control.

  2. Location Notes:
    a. For bathroom applications, the control should be placed at a level to detect humidity. Placing the control directly above a heater or near drafts is NOT recommended.
    b. For bathroom applications, the Wall Control should be placed in close proximity to the shower/tub/sink/etc. (the main source of humidity/steam/VOC) and at sink height or higher for effective monitoring of your indoor air quality.
    c. Place your Wall Control within the range of your Wi-Fi router or access point (approximately 100 feet).
    d. Avoid physical obstructions and radio interference in the surrounding area.

  3. Install the wall control in at least a 3″ deep switch box for #14 AWG wire or at least a 3 ½” deep switch box for #12 AWG wire. The control can be installed in either a metal outlet box or a plastic outlet box.

  4. Attach the incoming power line and ventilator power line to switch box. It may be necessary to use two side knockouts for some applications. Use proper connectors. Provide 6″ leads inside box and ventilation product.

  5. Make electrical connections following the diagrams provided below or in the Broan-NuTone OvertureTM app. Use wire nuts. Make sure both the control and the ventilator are properly grounded. Wire terminals accept up to #12 AWG MAX solid wire.
    a. Loosen screw terminals.
    b. Strip wire 0.275″ and insert the bare wire into the screw terminal opening.
    c. Tighten the terminal screw, making sure wire remains under the clamp. Torque the terminal screws to 3.5 in-lbs (.4 N-m).
    d. Note: Do not reuse wire formed into a “J” loop or wrapped around screw threads. The screw terminal is designed for the straight insertion of stripped wire for proper mechanical and electrical connection.

  6. Tuck wires in and fasten control to switch box using attached screws. Verify wall control orientation before installation. Note “TOP” direction shown on the wall control label.

  7. Attach switch plate (not included) using color-matched oval head screws.

  8. Download the Broan-NuTone OvertureTM App for step by step set-up instructions to connect your Wall Control to the OvertureTM system. Scan QR code to go to App Store.

BROAN 1103434 Overture Wall Control-1

BROAN 1103434 Overture Wall Control-2

For Warranty Statement, Service Parts, Technical Support, or to Register your product, please visit our website or call: In the United States – Broan- NuTone.com 800-558-1711. In Canada – Broan.ca or NuTone.ca 877-896-1119

Regulatory Information
The OvertureTM Wall Control 1103434 is certified to comply with applicable FCC and IC rules and regulations governing RF and EMI emissions. Refer to 1103434. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. The distance between user and device should be no less than 20 cm.

FCC Notice
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician to help.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

ISED Compliance Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Broan-NuTone LLC is under license. Other trademarks and trade names are those of their respective owners.
The Android robot is reproduced or modified from work created and shared by Google and used according to terms described in the Creative Commons 3.0 Attribution License.
Regulatory ID for 1103434 OvertureTM Wall Control FCC ID: 2ADLL-1103434

IC: 2143B-1103434
Made in China to the quality standards and specifications of
Broan-Nutone LLC Hartford, Wisconsin
www.broan-nutone.com 800-558-1711
Venmar Ventilation ULC Drummondville Quebec Canada www.broan.ca or www.nutone.ca 877-896-1119
For more information and user manuals scan QR code below.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals