LUPINE BTL2 PRO 5000 Lumen Professional Rechargeable LED Flashlight Instructions
- June 6, 2024
- LUPINE
Table of Contents
LUPINE BTL2 PRO 5000 Lumen Professional Rechargeable LED Flashlight
Safety Instructions
Warning! Avoid looking directly into the light emitted by the light or shining the light into your own eyes or the eyes of another person. If the light accidentally shines into your eyes, close your eyes and move your head out of the light beam. Do not use any strongly focusing optical device to look at the light beam. In cases where the light is used in a public or commercial setting, users should be provided with training concerning the safety measures for laser light.
This device may then be used by children 8 years of age or older, persons with limited physical, sensory or mental capabilities, as well as persons with no previous experience in handling such devices, if they are supervised by a person responsible for their safety.
Attention! Risk group 2: Proven optical radiation! Do not look into the lamp for a long time during operation. May be harmful to the eyes. Danger of glare: The strong glare of the lamp can be temporary Eyesight and afterimages feel dying Irritation, authorizations or treatment commands can.
Re-charge you battery before using the light. Carry a spare light with you at all times, as the product can potentially fail unexpectedly at any time. In the event of any physical or internal battery failure, do not attempt to repair. No user-serviceable parts!
Heat generation: The housing of Betty may heat up; so make sure that you always keep the light at a safe distance to any combustible or flammable materials. Could cause fire or death!
However, quiescent operation (without cooling the light housing) is possible at any time and will not damage the product. When the light is being used in a stationary state, the light will be dimmed after a few minutes to reduce the light’s temperature. Continuous operation at 45 watts is only possible with air flowing over the housing!
Important! Always disconnect the battery from the light at transport or storage! Otherwise the small amount of power used by the electronics will discharge the battery, and the lamp may be switched on accidentally.
Water resistance: All components are waterproof and can of course be used under extremely severe conditions. The lamp complies with IP protection class 68 but is NOT a diving lamp and is NOT suitable for use under water.
Locking mechanism: Before removing the flashlight, check the position of the lock. Make sure the lock is open. To remove or insert the flashlight into the docking station, you must overcome a clear pressure point.
Charging and Mounting
Docking Station
The flashlight can be charged in many different ways:
- By the included 12V adapter
- 12V cable and cigarette lighter socket
- Through the internal socket and a Lupine standard charger (not included)
- Direct connection to 12V – 24V DC through the included cable
Installation to the wall or inside the vehicle
To attach the docking station, use the holes in the anodized metal rail. We
recommend the use of four flat head screws, which should be selected according
to the ground. Ensure a solid foundation. It takes some force to remove the
lamp from the docking station.
Hint: We recommend you to set up the connection from an experienced vehicle builder or electrician. It is advisable to design the system in a way it is only charging when the ignition is switched on, in order to avoid discharging the vehicles battery. Always disconnect the electricity if working on the electronics. The charger at the end of the battery compartment automatically detects the voltage (12-24V Direct Current).
Warning! If the docking station is directly connected to 12-24V=, watch the polarity! Shorten the cable to the length you need.
Charging with power adapter or 12V cable
With the power adapter the Betty TL2 Pro can be charged from the wall
socket.
- Plug the supplied power adapter into your wall socket and connect it to the docking station.
- Make sure the lock is open. Set and press the TL2 Pro into the docking station. You must overcome a clear pressure point. A high resistance must also be overcome when the lamp is removed. Do not be hesitant.
- Charging starts automatically, the LEDs flash green. When the battery is full, the LEDs light green.
Charge via the internal charging socket
Alternatively, the Betty TL2 Pro can also be charged with many Lupine
standard chargers.
- Plug the charger into your wall outlet.
- Unscrew the rechargeable battery from the flashlight and the charging socket becomes visible.
- Plug the charger into the battery compartment.
- If the battery is charged via the charging socket, no LEDs illuminate at the end of the battery compartment. The feature is only available when using the docking station.
Operation
Initialization & voltage display:
When the lamp is connected to the battery, the software will run a self test.
All RGB LEDs will flash up and the lamp itself will flash once.
The battery voltage is then indicated by a blue and green LED, as follows:
- The blue LED flashes once for each volt; and then
- the green LED flashes once for each 1/10 of a volt.
To display the battery voltage again, unplug the light from the battery and then plug it in again.
Example: The blue LED flashes seven times and the green LED then flashes five times; this means that the measured voltage under load is 7.5 V. This display helps you assess the actual state of the battery prior to use.
Interpreting the voltage display:
More than 8.0 V: the battery is fully charged.
7.1 to 7.9 V: the battery needs charging.
6.5 to 7 V: the battery is not ready for use.
Note: To deactivate this display, simply press the button. In other
words, you needn’t let the display go through its whole cycle in order to use
the lamp.
The control electronics measures the voltage under load.
Thus, measurements using a voltmeter will not be comparable.
Switching on:
Press the power switch (DoubleClick) to turn the light on; two blue LEDs will
glow, indicating the 22W dimming level. Press the button rapidly to cycle
through other power levels. Refer to the chart on page 26 for the exact
meaning of the five (RGB) monitor LEDs, as well as instructions for
programming options additional to the factory-set 3-step mode.
Note: The red center LED will only run in a special mode, while otherwise just
the outer 6 LEDs will shine.
Luminous performance:
The ambient temperature and the use of high power levels can reduce power
to the LEDs, thus reducing their brightness, to avoid overheating the LEDs and
other electronics. The actual reduction is indicated by the status LEDs: e.g.,
after a certain period of time, 4 of the 5 blue status LEDs will be lit,
indicating that the power has been reduced from 45W in order to protect the
unit from heat damage.
Switching off:
Hold the button down (for more than one second) to switch off the lamp.
Discharged battery capacity:
When you shut off the lamp, the discharged battery capacity is shown via
flashing of the blue LED and then the green LED. This information can only be
displayed once as it is deleted when you unplug the battery.
The blue LED blinks once for each Ah (ampere hour), and then the green LED
blinks once for each 1/10 of an Ah.
Example: The blue LED flashes once and then the green LED flashes five times.
This indicates that 1.5 Ah have been drawn from the battery.
Battery warning:
The LEDs on the back of the lamp-head change color to indicate decreasing
voltage. When battery voltage drops below a certain level, the Backlight LED
changes from blue to green. Near the end of the battery’s charge, the light
turns red.
Safety advisory: When the battery is completely discharged ( all 5 red
LEDs blink with a red backlight on), the light will shut down after flashing a
few times.
In such a case, you should be careful.
Note: When permanently operating the lamp at high power, the battery warnings may be issued in very quick sequence.
Reserve power:
When the battery is completely discharged (all 5 red LEDs blink with a red
backlight on), the light will shut down after flashing a few times. To
activate the battery’s reserve power, double click the switch. This will give
you a few minutes more light, whose exact amount depends on the age of your
battery. The light emitted in reserve-power mode is a very low beam so as to
conserve power and keep the light going as long as possible. The red 5 LEDs
slowly flash when reserve power mode is activated and the backlight will be
red. When the reserve power has been completely discharged, the light will
shut down – so be careful.
Note: When operating the lamp only with 2 W or less, no reserve power will be available.
Warning: Do not switch on the light when the battery is discharged, as this will invariably damage the battery. Recharge the battery as soon as possible to avoid a deep discharged battery.
Customizing the brightness levels
You have the option to setup up to 4 brightness levels, in any sequence.
- Press and hold the button until one green LED lights up. release the button
- The range of brightness levels you can select will begin automatically to cycle, as shown below.
- Press the button at the brightness level you want. the first power-on click is presented
- Upon releasing the button, the sequence of brightness levels automatically restarts, allowing you to set a second level in the same manner as the first click set-up. This process can be repeated up to four times, but will stop when you quit making further selections, thus allowing your light to operate in 1-step, 2-step, 3-step,-or 4-step modes.
If in use, shown by green LED
Will not be signalised by a status LED
Center:
This setting activates the center LED to produce a low red light. The outer 6
LEDs will be disabled.
SOS:
The light will continue with SOS until the battery is empty. Use it carefully
and only in case of a real emergency. Due to the lamp’s high light output,
this signal is visible for several miles; the operating time is several hours.
Misuse may be prosecuted!
Flash:
This mode is extremely irritating and may by no means be misused.
Double click:
If this function is activated, the lamp may only be switched on with a quick
double click.
Useful for anybody who wants to avoid that the lamp is switched on
accidentally in particular during transport (e. g. in a backpack).
Stealth:
In stealth mode, initialization, voltage display, and battery warning usually
indicated by the button’s LEDs are partly deactivated. Of course “stealth on“
does not mean that our Betty TL Pro will no longer give light or will even
become invisible, however, LED indications will be reduced to a minimum.
Police-Mode (Special-Mode):
In the Police-Mode, the lamp only lights up, while the button is kept pressed.
The lamp stops shining at once, when you get off the button. To prevent an
activation by mistake, this mode is chosen in a special way. Press the button
8 times quickly during 2.5 – 3 seconds. To change back to the standard mode,
press the button again 8 times quickly.
Special Functions
Alternative Capacity Indicator (lamp head)
- Before activating the alternative capacity indicator, your battery must be fully charged.
- Press and hold the button until 2 green LEDs light up. release the button
- The range of battery capacities you can choose from will start automatically.
- You must approximate the correct range for your battery; e.g., for a 6.6Ah you would select 7 Ah (5 green LEDs).
Similar to our Smartcore batteries the red LEDs on the lamp head will now approximately show the remaining capacity.
Attention! When the lamp-head is disconnected from a battery, the indicator will not work correctly until the battery is fully recharged
Example: 70% Remaining capacity = 3 red LEDs on, 1 red LED blinking
Adjusting backlight low-battery warning:
Use this program to adjust the onset of the low-battery warning.
- Press and hold the button, until 3 green LEDs light up. release the button
- The threshold can be selected as shown below.
Recover factory settings:
- Press and hold the button, until 5 red LEDs turn on. release the button
- Disconnect the battery, and all factory settings will be restored.
Accessories
1/4 Inch Adapter:
The adapter allows to mount the light on a tripod.
Use the screws which came with the adapter to connect it to the light.
According to the long battery tank, we recommend a stable tripod.
Filter cap:
The special cap comes with an additional thread.
Thanks to the cap 55 mm filters, such as available as foto accessories can be
used.
Cleaning:
Only clean the lamp when it is fully assembled. If required, use warm water
and add some mild dishwashing detergent.
Transport:
Caution! Always separate the battery from the lamp!
Otherwise, the small amount of power used by the electronics will discharge
the battery. Furthermore, the lamp may be switched on accidentally. The
uncontrolled heat buildup could cause a fire or melt adjacent plastic
material.
Storage:
When the lamp will not be used for a longer period of time, fully charge the
battery and leave it connected to the charger. Choose a cool, dry place for
storage (basement etc.).
Opening the lamp housing:
Note! The lamp housing may be opened for installing an upgrade kit or a
lens.
Open the lamp housing’s front screw-on cover. Hold the rear of the lamp with
one hand while rotating the front cover to the left (counterclockwise) with
the other hand.
Once you have removed the cover, you will see the 7-array lens.
Please avoid touching the lenses directly.
Closing the lamp housing:
Check to ensure that the o-ring on the rear of the housing is correctly
positioned. The housing will only be waterproof if its o-ring is intact. After
completing this check, carefully screw down the housing cover. Important! The
thread must always run smoothly, otherwise, screw off the cover again
immediately and try again. The fine thread will not excuse any mishandling –
therefore, be extremely careful! Fully screw down the cover.
Troubleshooting
Light Output: Runtime: Betty TL2 Pro:
45 W | 5400 Lumens | 1 h 30 min. |
---|
34 W
28 W
| 4200 Lumens
3600 Lumens
| 2 h
2 h 30 min.
22 W| 3050 Lumens| 3 h 15 min.
16 W
12 W
8 W
3 W
| 2200 Lumens
1700 Lumens
1200 Lumens
470 Lumens
| 4 h 30 min.
6 h
9 h
24 h
2 W| 330 Lumens| 36 h
0.3 W
0.8 W
| 50 Lumens Center-LED| 240 h
90 h
Weight:
Betty TL2 Pro: 600 g incl. battery
Protection class: IP68
Battery life may vary depending on battery age, condition, and temperature.
Charging time: Betty TL2 Pro 7 h
Operating temperature: –25 °C – +70 °C
Docking Station:
Input voltage: 12 – 24 V=
Charging current: up to 1.5 A
Compatible batteries: Li-Ion 7.2V, 9.9 Ah with ORC
Lock: Mechanical lock
Terminals: Watch polarity
LED:
6 x Cree XM-L3
1 x Cree XP-E2 (with red center LED)
Battery and Orbital charging:
Betty TL2 Pro: 10.4 Ah ORC, 75Wh /7.2 V Li-Ion
Terminals: 3 hardgold-plated bronze parts
Current: 1.5 A max.
Power adapter:
Input: 100-240V~1.0A Max 50-60Hz
Output: 12V=
More informations at www.lupine.de
Miscellaneous
Lumen:
lm (Lumens) = Unit of luminous flux
Usually differentiated in measured and calculated values. Calculated values
often differ considerably from the actual light output. Our lumen values are
measured in our own calibrated integrating sphere.
The measurement takes place after 30 seconds, the so called ANSI method.
The laws governing the allowable application domain for this lighting system may vary from one country to another. We recommend that you inform yourself about the relevant laws in this domain in your country.
Warranty:
The product’s two year warranty applies to all components, as well as any
manufacturing defect. The warranty does not include the battery, however. In
addition, any modification or improper use of the product will void the
warranty.
Lupine lighting systems GmbH
Im Zwiesel 9, 92318 Neumarkt, Germany
Phone: +49 (0) 91 81 – 50 94 90
Fax: +49 (0) 91 81 – 50 94 915
E-Mail: info@lupine.de
www.lupine.de
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>