Cync / C by GE Installing 4-Wire Smart Switches

June 6, 2024
GE

Installing 4-Wire Smart Switches

Installation instructions for Single-Pole, 3-Way and 4-Way setups. Reminder that Cync 4-Wire Switches and Dimmers require neutral and ground wires.

Single-Pole Installation

Single-Pole installation means you are installing one switch that controls one circuit and one set of lights.

NOTE:  Video instructions will slightly differ if you are installing our 4-Wire On/Off Switches (Button, Toggle, Button).  The Line and Load wires on the back of these Smart Switches are interchangeable, allowing you to connect either black wire on the switch to the Line or Load wire from the wall.

Download the Installation Guide for the single-pole installation of your Cync/C by GE 4-Wire Smart Switch.

4-Wire Dimmers, Single-Pole Digital Installation Guide
(Motion Sensing Dimmer and Dimmer Switch)

4-Wire On/Off Button Switch, Single-Pole Digital Installation Guide

4-Wire On/Off Toggle/Paddle Switch, Single-Pole Digital Installation Guide

3-Way Installation

3-Way installation means you are installing two switches that control one circuit and one set of lights.

NOTE:  All switches on the same circuit must be replaced with a Cync or C by GE Smart Switch. For example, if you replace one switch on the circuit with Cync/C by GE Smart Switch, you will need to replace all the switches on that same circuit with a Cync/C by GE Smart Switch.
Download the Installation Guide for the 3-Way installation of your Cync/C by GE 4-Wire Smart Switch.

4-Wire Switch, 3-Way Digital Installation Guide

4-Way Installation

4-Way installation means you are installing three switches that control one circuit and one set of lights.
NOTE:  All switches on the same circuit must be replaced with a Cync or C by GE Smart Switch. For example, if you replace one switch on the circuit with Cync/C by GE Smart Switch, you will need to replace all the switches on that same circuit with a Cync/C by GE Smart Switch.
Download the Installation Guide for the 4-Way installation of your Cync/C by GE 4-Wire Smart Switch.

 4-Wire Switch, 4-Way Digital Installation Guide

Troubleshooting

Your switch is not in setup mode if the LED light on your switch is not flashing blue after you’ve installed it. This means you will not be able to connect it to the Cync app.

If the LED light did not turn on: here are some common solutions:

  1. Confirm the breaker is on
  2. Check that the switch is wired correctly

If the light ring is flashing red, this means the circuit is overloaded. Max load rating is 150W for LED and 450W for incandescent/halogen.

Downloads:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GE User Manuals

Related Manuals