CyberPower CP850PFCLCD PFC Sinewave UPS System User Manual

June 6, 2024
CyberPower

cyberpower logo

CyberPower CP850PFCLCD PFC Sinewave UPS System

CyberPower CP850PFCLCD PFC Sinewave UPS System

FEATURES

CyberPower CP850PFCLCD PFC Sinewave UPS System-1

  1. Power Switch
  2. Power-On Indicator
  3. LCD Module Display
  4. Down/Display Button
  5. Up/Mute Button
  6. Enter/Setup Button
  7. USB charging ports (Except for CP850PFCLCD)
  8. Battery and Surge Protected Outlets
  9. Full-time Surge Protected Outlets
  10. Circuit Breaker
  11. DB9/USB Ports to PC
  12. Wiring Fault Indicator (red)
  13. Communication Protection Ports (RJ45)

PRODUCT REGISTRATION

Thank you for purchasing a CyberPower product. This UPS is designed to provide unsurpassed power protection, operation, and performance during the lifetime of the product. Please take a few minutes to register your product at: www.CyberPowerSystems.com/registration.
Registration certifies your product’s warranty, confirms your ownership in the event of a product loss or theft, and entitles you to free technical support. Register your product now to receive the benefits of CyberPower ownership.

IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.

CAUTION: To prevent the risk of fire or electric shock, install in a temperature and humidity-controlled indoor area free of conductive contaminants. (Please see specifications for acceptable temperature and humidity range.)

  • To reduce the risk of electric shock, do not remove the cover except to service the battery. Turn off and unplug the unit before servicing the batteries. There are no user-serviceable parts inside except for the battery.
  • Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
  • The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the unit.
  • To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a computer component.
  • To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in accordance with the National Electric Code, ANSI/NFPA 70.
  • Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment, ANSI/NFPA 75.
  • Do not dispose of batteries in a fire. The batteries may explode.
  • Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!
CyberPower Systems does not sell products for life support or medical applications. DO NOT use in any circumstance that would affect operation and safety of life support equipment, any medical applications or patient care.

DO NOT USE WITH OR NEAR AQUARIUMS!
To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation from the aquarium can cause the unit to short out.

DO NOT USE THE UPS ON ANY TRANSPORTATION!
To reduce the risk of fire or electric shock, do not use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.

INSTALLING YOUR UPS SYSTEM UNPACKING

Inspect the UPS upon receipt.
The box should contain the following:
(a) UPS unit
(b) User’s manual
(c) USB A+B Type cable
(d) Function Setup Guide
PowerPanel® Personal software is available on our website. Please visit www.cyberpowersystems.com and go to the Software Section for a free download.

SUPPORTS Active PFC POWER SUPPLIES
This CyberPower UPS system supports High-Efficiency power supplies with Active Power Factor Correction (Active PFC). Active PFC is used to improve the efficiency of power delivery. The current US Energy Star® Program Requirements for Computers mandates Active PFC for all power supplies over 100 watts. Additionally, programs such as 80 Plus® are often used to identify high- efficiency power supplies with Active PFC.

OVERVIEW
The CP850PFCLCD/CP1000PFCLCD provides complete power protection from utility power that is not always consistent. The CP850PFCLCD/CP1000PFCLCD features 1,150 Joules of surge protection. Both units provide long-lasting battery backup during power outages with maintenance-free batteries. The CP850PFCLCD/CP1000PFCLCD ensures consistent power to your computer system and includes software that will automatically save your open files and shut down your computer system during a utility power loss.

AUTOMATIC VOLTAGE REGULATOR

The CP850PFCLCD/CP1000PFCLCD stabilizes inconsistent utility power voltage to nominal levels that are safe for equipment. Inconsistent incoming utility power may be damaging to important data files and hardware, but with Automatic Voltage Regulation (AVR), damaging voltage levels are corrected to safe levels.
AVR automatically increases low utility power to a consistent and safe output voltage.

DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

  1. Ensure that the equipment plugged into the outlet does not exceed the UPS unit’s rated capacity (850VA/510W for CP850PFCLCD, 1000VA/600W for CP1000PFCLCD). If the rated capacities of the unit are exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
  2. There are many factors that can affect the amount of power that your computer system will require. It is suggested that the load placed on the battery outlets not exceed 80% of the unit’s capacity.

HARDWARE INSTALLATION GUIDE

  1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure the battery’s maximum charge capacity, it is recommended that you charge the battery for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically charge whether the UPS is turned on or turned off.CyberPower CP850PFCLCD PFC Sinewave UPS System-3
    Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment. The first time you turn the UPS on, you will need to have it connected to AC power or it will not power up.

  2. With the UPS unit turned off and unplugged, connect your computer, monitor, and any other peripherals requiring battery backup into the battery power supplied outlets. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump or other large electrical devices into the “Battery and Surge Protected Outlets”. The power demands of these devices will overload and damage the unit.

  3. Plug the UPS into a 2-pole, 3-wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc.). The warranty prohibits the use of extension cords, outlet strips, and surge strips in conjunction with the UPS unit.

  4. Press the power switch to turn the unit on. The Power On indicator light will illuminate and the unit will “beep”. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.

  5. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.

  6. To store the UPS for an extended period of time, cover it and store with the battery fully charged. While in storage, recharge the battery every three months to ensure optimal battery life.

  7. Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility.

CYBERPOWER GREENPOWER UPS™ TECHNOLOGY

Advanced Energy-Saving Patented Bypass Technology
CyberPower’s patented GreenPower UPS™ with Bypass Technology reduces UPS energy costs by up to 75% compared to conventional UPS models. Even when utility power is normal, conventional UPS models constantly pass power through a transformer. By contrast, under normal conditions, the advanced circuitry of a GreenPower UPS™ bypasses the transformer. As a result, the power efficiency is significantly increased while decreasing waste heat, using less energy, and reducing energy costs. When an abnormal power condition occurs, the GreenPower UPS™ automatically runs power through its transformer to regulate voltage and provide “safe” power. Since utility power is normal over 88% of the time, the GreenPower UPS™ operates primarily in its efficient bypass mode. The GreenPower UPS™ is also manufactured in accordance with the Restriction on Hazardous Substances (RoHS) directive making it one of the most environmentally friendly on the market today.

SYSTEM FUNCTION BLOCK DIAGRAM

CyberPower CP850PFCLCD PFC Sinewave UPS System-4

BASIC OPERATION

  1. Power Switch
    Used as the master on/off switch for equipment connected to the battery power supplied outlets.

  2. Power-On Indicator
    This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.

  3. LCD Module Display
    High resolution and the intelligent LCD display show all the UPS information using icons and messages. For more information please review the “Definitions for Illuminated LCD Indicators” section below.

  4. Down/Display Button
    The button can be used to select the LCD display contents including Input Voltage, Output Voltage, and Estimated Run Time. Short press the button to scroll down the function menu. Pressing the button for 2 seconds will keep the LCD display always on or turn the LCD display off while in AC/Utility power mode. For more information about the Down/Display Button, please refer to the Function Setup Guide.

  5. Up/Mute Button
    Short press the button to scroll up the function menu. Holding the button for more than 2 seconds will silence the alarm. For more information about the Up/Mute Button, please refer to the Function Setup Guide.

  6. Enter/Setup Button
    Press the button for 2 seconds to enter the setup menu and then select the functions for configuration. For more information about the Enter/Setup Button, please refer to the Function Setup Guide.

  7. USB charging ports (Except for CP850PFCLCD)
    The USB Power ports (Type A and Type C) provide DC 5V 3.1A power output.

  8. Battery and Surge Protected Outlets
    The unit has 5 battery-powered and surge-protected outlets to ensure temporary uninterrupted operation of your equipment during a power failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large electrical devices into the“Battery and Surge Protected Outlets.” The power demands of these devices will overload and possibly damage the unit.)

  9. Full-Time Surge Protected Outlets
    The unit has five surge suppression outlets.

  10. Circuit Breaker
    Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection.

  11. USB Port to PC
    The USB communication port allows communication between the USB port on the computer and the UPS unit.
    DB9 Port This port is used for connecting between the UPS and equipment designed to operate with dry contact closure.

  12. Wiring Fault Indicator (red)
    This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring. If this is illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The unit will not provide surge protection without being plugged into a grounded and properly wired wall outlet.

  13. Communication Protection Ports (RJ45) Communication  protection ports, bi-directional, will protect a 10/100/1000 Ethernet connection. (RJ45).

REPLACING THE BATTERY

Replacement of batteries located in an OPERATOR ACCESS AREA

  1. When replacing batteries, replace with the same number of the following battery: CyberPower / RB1290 for the CP850PFCLCD / CP100PFCLCD.
  2. CAUTION! Risk of Energy Hazard, 12 V, maximum 9 Ampere-hour battery. Before replacing batteries, remove conductive jewelry such as chains, wristwatches, and rings. High energy conducted through these materials could cause severe burns.
  3. CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
  4. CAUTION! Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic.

CAUTION – RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS

BATTERY REPLACEMENT PROCEDURE: CP850PFCLCD/CP1000PFCLCD

CyberPower CP850PFCLCD PFC Sinewave UPS System-5

  1. Turn off and unplug all connected equipment.
  2. Turn the UPS off and unplug it from the AC power source.
  3. Turn the UPS on its side.
  4. Remove the retaining screw located on the bottom of the UPS.
  5. Slide the battery compartment cover completely off of the unit.
  6. Remove the batteries from the compartment.
  7. Disconnect the battery wires from the batteries.
  8. Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same color connectors from the battery pack.
  9. Put the batteries back into the compartment.
  10. Slide back the battery compartment cover and tighten the retaining screw.
  11. Recharge the UPS for 8-16 hours to fully charge the battery.

REMINDER: Batteries are considered HAZARDOUS WASTE and must be disposed of properly. Most retailers that sell lead-acid batteries collect used batteries for recycling, as required by local regulations.

DEFINITIONS FOR ILLUMINATED LCD INDICATORS

  1. ONLINE
    The UPS is supplying utility power to connected equipment.

  2. ENERGY-SAVING
    The UPS in energy-saving bypass mode. See the “CyberPower GreenPower UPS™ Technology” section for more information.

  3. AVR (Automatic Voltage Regulation): This icon appears whenever your UPS is automatically correcting low AC line voltage without using battery power. This is a normal, automatic operation of your UPS, and no action is required on your part.

  4. ON BATTERY
    During a severe planned power suppression or power outage, this icon appears and an alarm sounds (two short beeps followed by a pause) to indicate the UPS is operating from its internal batteries. During a pro-longed planned power suppression or power outage, the alarm will beep rapidly every 1/2 second (and the BATT.CAPACITY meter shows one 20% capacity segment shaded. The capacity depends on how much load added and the runtime left.) to indicate the UPS’s batteries are nearly out of power. You should save files and turn off your equipment immediately or allow the software to shut the system down.

  5. BATTERY CAPACITY
    This meter displays the approximate charge level (in 20% increments) of the UPS’s internal battery. During a power outage or severe planned power suppression, the UPS switches to battery power, the BATTERY icon appears, and the charge level decreases.

  6. FAULT
    This icon appears if there is a problem with the UPS. Press the POWER button to turn off the UPS.
    E01: Charger Fault – Overcharge
    (Contact CyberPower Systems for support.) E02: Charger Fault – No Charge
    (Contact CyberPower Systems for support.) E11: Battery Overvoltage
    (Contact CyberPower Systems for support.) E21: Output Short (Turn on the UPS again.) E22: Overload (Unplug at least one piece of equipment from battery outlets and turn the UPS on again.)CyberPower CP850PFCLCD PFC Sinewave UPS
System-6

  7. OVERLOAD
    This icon appears and an alarm sounds
    to indicate the battery-supplied outlets are overloaded. To clear the overload, unplug one piece of equipment from the battery-supplied outlets at a time until the icon turns off and the alarm stops.

  8. CURRENT LOAD
    This meter displays the approximate output load level (in 20% increments) of the UPS battery outlets.

  9. SCHEDULE
    Users can set up the schedule to turn on and shut down the computer and UPS through PowerPanel® Personal software. The LCD display will show how much time is left be-fore the UPS will turn back on or shut down.

  10. MUTE
    This icon appears whenever the UPS is
    in silent mode. However, when there is a problem with the UPS, the alarm will still beep even in silent mode.

  11. INPUT meter
    This meter measures the AC voltage that the UPS system is receiving from the utility wall outlet. The INPUT voltage meter can be used as a diagnostic tool to identify poor-quality input power.

  12. OUTPUT meter
    This meter measures, in real-time, the AC voltage that the UPS system is providing to the computer, such as normal AC line mode, AVR mode, and battery backup mode. (Note: The OUTPUT meter shows the status of the battery back up outlets in terms of load, frequency, and voltage.)

  13. EVENT
    This meter records the number of power outages.

  14. ESTIMATED RUNTIME
    This displays the runtime estimate of the UPS with current battery capacity and load.

  15. SENSITIVITY SETUP
    This meter is also used to set up the UPS sensitivity when you are in the programming mode. If the connected equipment can tolerate more power events (example: unstable power often associated with stormy weather), select Low Sensitivity and the UPS will go to Battery Mode less often. If the connected equipment is more sensitive to power events, select High Sensitivity and the UPS will go to Battery Mode more often.

For more information about functions setup, please refer to the Function Setup Guide.

TROUBLESHOOTING

Problem Possible Cause Solution
Circuit breaker button is projecting from the back of the unit. Circuit
breaker has been tripped due to an overload. Turn the UPS off and unplug at

least one piece of equipment. Wait 10 seconds, reset the circuit breaker by depressing the button, and then turn the UPS on.
The UPS does not perform expected runtime.| Battery not fully charged.| Recharge the battery by leaving the UPS plugged in.
Battery is worn out.| Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support.
The UPS will not turn on.| The on/off switch is designed to prevent damage from rapidly turning it off and on.| Turn the UPS off. Wait 10 seconds and then turn the UPS on.
The unit is not connected to an AC outlet.| The unit must be connected to a 110/120V 60Hz outlet.
The battery is worn out.| Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support.
Mechanical problem.| Contact CyberPower Systems at: cyberpowersystems.com/support.
PowerPanel® is inactive (all icons are gray).| The USB cable is not connected.| Connect the USB / serial cable to the UPS unit and an open USB/ serial port on the back of the computer. You must use the cable that came with the unit.
The USB cable is connected to the wrong USB port.| Check the back of the computer for an additional USB / serial port. Move the cable to this port.
Problem| Possible Cause| Solution
---|---|---
PowerPanel® is inactive (all icons are gray).| The unit is not providing battery power.| Shut down your computer and turn the UPS off. Wait 10 seconds and turn the UPS back on. This should reset the unit.
The serial cable is not the cable that came with the unit.| Please use the serial cable that came with the unit for the software.
The USB power ports are not providing power to the connected devices.| The USB power port has Over Current Protection design. When the total current of connected devices is over 3 .1A, the USB power ports will stop providing power to the connected devices.| Turn  the UPS off and unplug at least one piece of device connected to the USB power port and then turn the UPS on.

Additional troubleshooting information can be found at “Support” at www.CyberPowerSystems.com

TECHNICAL SPECIFICATIONS

Problem Possible Cause Solution
PowerPanel® is inactive (all icons are gray). The unit is not providing
battery power. Shut down your computer and turn the UPS off. Wait 10 seconds

and turn the UPS back on. This should reset the unit.
The serial cable is not the cable that came with the unit.| Please use the serial cable that came with the unit for the software.
The USB power ports are not providing power to the connected devices.| The USB power port has Over Current Protection design. When the total current of connected devices is over 3 .1A, the USB power ports will stop providing power to the connected devices.| Turn  the UPS off and unplug at least one piece of device connected to the USB power port and then turn the UPS on.

FCC COMPLIANCE STATEMENT

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
    Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Canadian Compliance Statement
CAN ICES-3 (B)/NMB-3(B)

LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE

Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected Equipment Guarantee.
Where Can I Get More Information?
The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty.
For further information please feel free to contact CyberPower at:
Cyber Power Systems (USA), Inc. 4241 12th Ave E., STE 400, Shakopee, MN 55379;call us at 877-297-6937; or submit a web ticket online at cyberpowersystems.com/support.
Cyber Power Systems (USA), Inc. encourages environmentally sound methods for disposal and recycling of its UPS products. Please dispose and/or recycle your UPS and batteries in accordance to the local regulations of your state.

WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.
© 2021 CyberPower Systems (USA), Inc. PowerPanel® Personal is a trademark of Cyber Power Systems(USA) Inc.
All rights reserved. All other trademarks are the property of their respective owners.