SANELA SUI02AC Urinal Flush Control Installation Guide
- June 10, 2024
- SANELA
Table of Contents
Installation & maintenance instructions.
General Information
- Designed for indoor use only. Do not expose to elements of nature.
- All plumbing and electrical connection must be made in accordance with AS/NZ3500 and installation with AS/NZ3500.2.
Warnings
- Read all instructions before attempting to install this system. It is recommended a qualified & registered plumber completes the install.
- Ensure pipe work is thoroughly flushed before installing the flush control (internal solenoid). Solenoid components are susceptible to debris and require additional flushing compared to a standard plumbing fixture.
- Consideration should be given to any regulations relating to an air gap, an air break or double check valve to protect against back flow.
Operating Instructions and Parts Manual
Please read carefully before attempting to assemble, install, operate or
maintain the product described. Protect yourself and others by observing all
safety information. Failure to comply with instructions could result in
personal injury and/ or property damage. Retain instructions for future
reference.
Sanela Urinal Flush Control
Sensor operated flush control for single urinal. Non touch infrared system
reacts to user attendance within active range and flushes once the user has
left. High quality electronics combined with elegant aesthetics.
Specifications
Power Supply | Mains 230V AC, 50Hz (input) 24V (output) |
---|---|
Location | Wall mounted above the urinal |
Control | Infra-red sensor |
Stainless Steel Cover | 170 x 170 x 10mm |
Mounting Box | 140 x 140 x 75mm |
Operating Voltage | Mains 24V D, 7W |
Active Range | 0.6 – 0.75 m – system reacts to user infront of urinal at max |
distance of 0.7m & min stay time of 7.5secs
Flush Cycles| Adjustable 0.5 secs – 15.5secs Hygiene Flush: 24hrs after last
use
Recommended Pressure| 0.1 – 0.6 Mpa (1-6 Bar)
Rate of Flow| 18 L/min (inf. Data) – Possible to regulate flow via ball valve
Water Inlet| Male thread G 3/4”
Water Outlet| Male thread G 3/4”
Warranty| 24 months
Product Code| SUI02AC
Planning
- Ensure an appropriate piping design (sizing etc). This will eliminate issues arising from flow, pressure and water hammering.
- Where appropriate install necessary filters, water hammering arrestors and water pressure reducing valves (recommended pressure 1 to 6 bar). This will minimise future maintenance.
Components
1 | Stainless steel cover |
---|---|
2 | Mounting box with intergrated power supply |
3 | Screw x 4 |
4 | Allen key |
Standard Functions
Person stays within active range for minimum stay of 7.5secs| Water flows after person leaves active range
Hygiene flush activates automatically 24 hourly| Operating pressure range
Installation
Important
To be installed in accordance with all NZ electrical regulations. It must be
carried out by a qualified professional.
Ensure mains power supply is off.| Ensure piping arrangement aligns with water
inlet/ outlet.
Make certain a power supply connection has been allowed for.
Note: please ensure pipework has been flushed thoroughly.| Pass mains (230V)
power supply into mounting box via grommet. Connect pipework securely.
Reinstate the mounting surface if applicable.
Mounting box should be flush with finished wall surface.| Remove cardboard
cover from mounting box.
Remove safety cover to access intergrated power
supply.| Connect external mains power supply to wago connectors – note
polarity.
Securely replace safety cover and ensure it is sealed shut. Remember to pass
the outlet supply wires through to main area of mounting box.| Using the allen
key, remove 2 x security screws from the bottom of stainless steel cover and
seperate cover from plate.
Fix plate to mounting box (4 x screws)| Connect electronics to solenoid valve.
Connect mains power supply to electronics via wago
connector. Note polarity.| Refit stainless steel cover by carefully inserting
top mounting points first, followed by tightening of 2 x security screws at
the bottom – use allen key.
Turn power supply on. It is necessary, for the proper function, to keep the
unit under constant voltage (don´t connect the power supply unit behind the
switch into the light circuit.) Once power on, do not come within active range
for 90 seconds to allow sensor to calibrate.
Important
Pipework is required to be flushed thoroughly prior to installation.
Foreign debris may reduce level of flow and in some cases damage the solenoid
valve.
- The sensor of the unit must not be obstructed.
- Avoid positioning reflective objects or surfaces in front of the sensor. This can cause false activation i.e. mirrors.
- All plumbing and electrical installation must be carried out by a qualified person and in accordance with applicable codes and regulations.
Note:
If you require to modify any of the factory settings please request the Sanela
remote SLD03.
Maintenance
- It is recommended that the solenoid valve and all filters be inspected for foreign debris and cleaned annually (more frequently if necessary)
- Clean cover regularly using soapy water and a soft cloth or wet sponge
- DO NOT clean cover with any abrasive material or chlorine/acid based cleaning product. This may damage the filter of the infrared sensor and/or the finish.
Troubleshooting
Symptom | Possible Cause | Corrective Action |
---|---|---|
No water flow – sensor LED blinked when within active range | a. Water supply |
b. Water connections
c. Filter is clogged
d. Faulty solenoid| a. Ensure water at source
b. Ensure connections
c. Clean filter (any valves and solenoid)
d. Replace solenoid
No water flow – Sensor LED did not blink when within active range| a. Power
supply
b. Power connections to wago connectors
c. IR sensor damaged or faulty| a. Ensure power at source
b. Check all connections and polarity
c. Replace IR sensor filter
Water doesn’t stop flowing| a. Dirty IR sensor
b. Obstruction in detection zone
c. Water drop on sensor eye
d. Ghost sensing due to reflection
e. Debris in solenoid| a. Clean IR sensor
b. Remove obstruction
c. Wipe sensor
d. Remove reflective surface or reposition
e. Clean and/or replace solenoid
Reduced flow rate| a. Filter clogged
b. Water supply| a. Clean filter
b. Check pressure / flow at source
Supreme Comprehensive Warranty
Your Sanela Urinal Flush is fully guaranteed against defective materials and
faulty workmanship commencing from the date of sale (according to SPL’s
records), subject to it being installed and maintained in accordance with the
manufacturer’s instructions.
SPL (2021) Limited warrants that should any part of the fush control fail
within the given warranty period (24 months), it will be remedied by SPL. The
flush control should be returned to SPL (2021) Limited for all warranty
claims. The cost of cartage will be payable by the customer.
This warranty excludes:
-
Incorrect installation, or installation that does not specifically follow the installation guidelines supplied
-
Failure to follow manufacturer’s maintenance instructions
-
Damage/Failure resulting from:
– the use of non-authorised parts
– authorised parts not installed in accordance with the manufacturer’s instructions
– accidental damage, negligent use, misuse, vandalism, neglect
– damage caused either directly or indirectly by external sources (incorrect power supply, natural disaster, or insect infestation) -
Water ingress caused by property maintenance or flooding
-
Negligent cleaning practices (water ingress, harmful chemical etc)
The above includes consequential damage to any other goods, furnishings, or property. -
Normal wear and tear and consumable parts (batteries etc)
-
This warranty does not displace any statutory warranty in relation to the unit but any liability of SPL (2021) Limited under any statutory warranty will be limited to a replacement or repair of the unit or payment of the cost of such replacement or repair at the sole discretion of SPL (2021) Limited
Note:
- Warranty only extends to products purchased and installed in New Zealand.
- Contamination or poor water quality is not covered by product warranty.
- Damage to solenoid caused by inadequate flushing or excess water pressure is not covered by the product warranty.
SPL Limited
PO Box 437, Cambridge 3450
New Zealand
p. +64 7 823 5790
e. office@splwashrooms.co.nz