SANELA Untitled Austere Sensor Tap Installation Guide
- June 1, 2024
- SANELA
Table of Contents
- SANELA Untitled Austere Sensor Tap
- Product Information
- Product Usage Instructions
- Installation & maintenance instructions.
- Operating Instructions and Parts Manual
- Specifications
- Planning
- Components
- Standard Functions
- Faucet Installation
- Maintenance
- Troubleshooting
- Supreme Comprehensive Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SANELA Untitled Austere Sensor Tap
Product Information
Specifications
-
Finish: Tempered Water
-
Water Temperature: Cold and pre-mixed water
-
Power Supply: 4 X AA batteries
-
Control: Sensor activated tapware
-
Operating Voltage: Not specified
-
Active Range: Hands within active range, water flows; hands
removed from active range, water stops -
Recommended Pressure: Operating pressure range
-
Rate of Flow: Not specified
-
Water Inlet Dimensions: Not specified
-
Warranty: Not specified
Product Usage Instructions
Components
- O-ring & gasket
- Mounting plate
- Hex nut
- Mounting screws to solenoid valve to battery housing
- Faucet components
- Angle valve
- Connection hose
- Filter
- Solenoid valve
- Battery housing
Faucet Installation
- Install 1/2 angle valve.
- Flush lines thoroughly.
- Fit mounting screws, o-ring, and rubber gasket.
- Pass mounting screws, hose, and electrical connections through the vanity.
- Fit mounting plate and hex nuts.
- Fit filter into angle valve.
- Fit remaining connection hose and solenoid. Note arrow on solenoid valve for water flow direction.
- Connect faucet to solenoid valve.
- Turn angle valve on and check all connections.
- Remove lid of battery housing.
- Insert 4 x AA batteries into housing ensuring correct polarity.
- Place batteries back in housing and close lid securely.
FAQ (Frequently Asked Questions)
- Troubleshooting
- Symptom: No water flow, LED on sensor flashing red when hands are within active range?
- Possible Causes: a. Water supply b. Water connections c. Filter is clogged d. Faucet to solenoid power connection e. Batteries are flat f. Faulty solenoid
- Corrective Action: a. Ensure water at source b. Ensure connections c. Clean filter (angle valve and solenoid) d. Reconnect plugs from…
AUSTERE – BATTERY POWERED
Installation & maintenance instructions.
General Information
- Designed for indoor use only. Do not expose to elements of nature.
- All plumbing and electrical connections must be made in accordance with AUS / NZ standards.
Warnings
- Read all instructions before attempting to install this system. It is recommended a qualified & registered plumber completes the install.
- Ensure pipe work is thoroughly flushed before installing the solenoid assembly. Solenoid components are susceptible to debris and require additional flushing compared to a standard plumbing fixture.
- Consideration should be given to any regulations relating to an air gap, an air break or double check valve to protect against back flow.
Operating Instructions and Parts Manual
- Please read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference.
- Sanela Austere Sensor Tap
- Sensor activated tapware for cold and pre-mixed water. High quality electronics combined with elegant aesthetics.
Specifications
Planning
- Ensure an appropriate piping design (sizing etc). This will eliminate issues arising from flow, pressure and water hammering.
- Where appropriate install necessary filters, water hammering arrestors and water pressure reducing valves (recommended pressure 1 to 6 bar). This will minimise future maintenance.
- Install the angle valve to enable ease of future maintenance.
Tempered Water
An appropriate thermostatic mixing valve (TMV3) should be installed to ensure a safe regulated water temperature. These are available from SPL – SST THERMO VALVE
Components
1 | Faucet components |
---|---|
2 | 4 X AA batteries |
3 | Angle valve |
4 | Connection hose |
5 | Filter |
6 | Solenoid valve |
7 | Battery housing |
Standard Functions
- Hands within active range, water flows
- Hands removed from active range, water stops
- Operating pressure range
- After 5 mins of use water will stop
Faucet Installation
-
Install 1/2” angle valve
-
Flush lines thoroughly
-
Fit mounting screws, o-ring and rubber gasket
-
Pass mounting screws, hose and electrical connections through vanity.
-
Fit mounting plate and hex nuts
-
Fit filter into angle valve
-
Fit remaining connection hose and solenoid. Note arrow on solenoid valve for water flow direction
-
Connect faucet to solenoid valve
-
Turn angle valve on and check all connections
-
Remove lid of battery housing
-
Insert 4 x AA batteries into housing ensuring correct polarity
-
Place batteries back in housing and close lid securely
-
Connect battery to faucet by aligning guide lines on respective cables
-
Secure battery housing to the wall using the adhe-sive strips provided.
-
Once the battery housing is connected, faucet will automatically adjust sensing range during first 10 seconds. The LED on sensor will continually flash, do not come in active range during this time.
-
Do not come within active range
Important
- Pipework is required to be flushed thoroughly prior to faucet and solenoid installation. Foreign debris may reduce level of flow and in some cases damage the solenoid valve.
- The sensor of the faucet must not be obstructed.
- Avoid positioning reflective objects or surfaces in front of the faucet sensor. This can cause false activation i.e. mirrors opposite faucet. With wall mounted faucets pay particular attention to the distance between the bottom of the basin and the faucet (minimum of 300mm) and the location and material of the basin waste (avoid mounting directly over the waste and/or choose non reflective options).
- All plumbing and electrical installation must be carried out by a qualified person and in accordance with applicable codes and regulations.
Note: If you require to modify any of the factory settings please request the Sanela remote SLD03.
- Activation Range
- Time Delay
- Hygienic Flush
Maintenance
- It is recommended that the solenoid valve and all filters be inspected for foreign debris and cleaned annually (more frequently if necessary)
- Clean faucet regularly using soapy water and a soft cloth or wet sponge
- DO NOT clean faucet with any abrasive material or chlorine/acid based cleaning product. This may damage the filter of the infrared sensor and/or the finishing of the faucet.
- Check batteries periodically. Flashing lights will indicate when the battery voltage is below 10% capacity
Troubleshooting
Symptom | Possible Cause | Corrective Action |
---|
No water flow – is LED on sensor flashing red when hands are within active range?|
- Water supply
- Water connections
- Filter is clogged
- Faucet to solenoid power connection
- Batteries are flat
- Faulty solenoid
|
- Ensure water at source
- Ensure connections
- Clean filter (angle valve and solenoid)
- Reconnect plugs from faucet to solenoid valve
- Replace batteries
- Replace solenoid
No water flow – LED on sensor NOT flashing when hands are within active range.|
- Power supply
- IR sensor damaged
- Faulty IR sensor
|
- Check battery housing connection & batteries
- Replace IR sensor filter
- Replace IR sensor
Water doesn’t stop flowing|
- Dirty IR sensor
- Obstruction in detection zone
- Water drop on sensor eye
- Ghost sensing due to reflection
- Debris in solenoid
|
- Clean IR sensor
- Remove obstruction
- Wipe sensor
- Remove reflective surface or reposition
- Clean and/or replace solenoid
Reduced flow rate|
- Filter clogged
- Aerator clogged
- Water supply
|
- Clean filter
- Clean aerator
- Check pressure / flow at source
Supreme Comprehensive Warranty
- Your Supreme sensor tap is fully guaranteed against defective materials and faulty workmanship commencing from the date of sale (according to SPL’s records), subject to it being installed and maintained in accordance with the manufacturer’s instructions.
- SPL (2021) Limited warrants that should any part of the sensor tap fail within the given warranty period (24 months), it will be remedied by SPL. The tap should be returned to SPL (2021) Limited for all warranty claims. The cost of cartage will be payable by the customer.
This warranty excludes:
- Incorrect installation, or installation that does not specifically follow the installation guidelines supplied
- Failure to follow manufacturer’s maintenance instructions
- Damage/Failure resulting from:
- the use of non-authorised parts
- authorised parts not installed in accordance with the manufacturer’s instructions
- accidental damage, negligent use, misuse, vandalism, neglect
- damage caused either directly or indirectly by external sources (incorrect power supply, natural disaster, or insect infestation)
- Water ingress caused by property maintenance or flooding
- Negligent cleaning practices (water ingress, harmful chemical etc)
The above includes consequential damage to any other goods, furnishings, or property.
- Normal wear and tear and consumable parts (batteries etc)
- This warranty does not displace any statutory warranty in relation to the dispenser but any liability of SPL (2021) Limited under any statutory warranty will be limited to a replacement or repair of the dispenser or payment of the cost of such replacement or repair at the sole discretion of SPL (2021) Limited
Note:
- Warranty only extends to products purchased and installed in New Zealand.
- Contamination or poor water quality is not covered by product warranty.
- Damage to solenoid caused by inadequate flushing or excess water pressure is not covered by the product warranty.
- SPL Limited
- PO Box 437, Cambridge 3450 New Zealand
- p. +64 7 823 5790
- office@splwashrooms.co.nz
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>