SANELA SST91AC Spartan Sensor Tap Instruction Manual

June 1, 2024
SANELA

SANELA SST91AC Spartan Sensor Tap Instruction Manual

General Information

  • Designed for indoor use only. Do not expose to elements of nature.
  • All plumbing and electrical connection must be made in accordance with AUS / NZ standards.

Warnings

  • Read all instructions before attempting to install this system. It is recommended a qualified & registered plumber completes the install.
  • Ensure pipe work is thoroughly flushed before installing the faucet (internal solenoid). Solenoid components are susceptible to debris and require additional flushing compared to a standard plumbing fixture.
  • Consideration should be given to any regulations relating to an air gap, an air break or double check valve to protect against back flow.

Operating Instructions and Parts Manual

Please read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/ or property damage. Retain instructions for future reference.

Sanela Spartan Sensor Tap

Sensor activated tapware for cold and pre-mixed water. High quality electronics combined with elegant aesthetics.

Specifications

Finish : Stainless Steel construction
Water Temperature: For cold or premixed water (thermostatic mixing valve available)
Power Supply: 24V DC (230V AC into power supply)
Control : Infra-red sensor
Operating Voltage : 24V DC, 3W
Active Range: Standard 0.13 – 0.19 m, START/STOP program 0.05 – 0.15 m
Recommended Pressure: 0.1 – 0.6 Mpa (1-6 Bar)
Rate of Flow : 3.8 l/min (6 l/min or 1.9L/m avaiable on request)
Water Inlet: Male thread G 1/2”
Dimensions: Height 141mm, Depth 140mm, Tap diameter Ø 50, Hole Ø 35mm, Nosing 105mm, Discharge height 98mm
Warranty: 24 Months

Planning

  • Ensure an appropriate piping design (sizing etc). This will eliminate issues arising from flow, pressure and water hammering.
  • Where appropriate install necessary filters, water hammering arrestors and water pressure reducing valves (recommended pressure 1 to 6 bar). This will minimise future maintenance.
  • Install the angel valve to enable ease of future maintenance.

Tempered Water

  • An appropriate thermostatic mixing valve (TMV3) should be installed to ensure a safe regulated water temperature. These are available from SPL – SST THERMO VALVE

Components

Components

1 Hex nut
2 Internal solenoid valve
3 Filter
5 Connection hose
6 Gasket (top)
7 Mounting plate (top)
8 Mounting plate (bottom)
9 Mounting screw
10 Gasket (bottom)

Standard Functions

START/STOP

1
| 2
| 3

  1. Hands within active range, water flows

  2. Hands removed from active range, water stops

  3. Operating pressure range

  4. After 5 mins of use  water will stop
    Standard Functions

External Power Supply Installation

External Power Supply Installation

Input 230V / 50 Hz
Output 24 V DC
IP rating IP 55
Operating temperature 5°C – 40°C
Rated power 10W

Important
To be installed in accordance with all NZ electrical regulations. It must be carried out by a qualified professional.

Positioning of the mounting box should be 500mm from the floor and consider:

  1. Moisture ingress due to plumbing fault
  2. Ongoing maintenance and accessibility

The mounting box can be surface mounted or within the service or ceiling cavity.

  1. Ensure mains power supply is off
    External Power Supply Installation

  2. Mark mounting point(s) on surface
    External Power Supply Installation

  3. Drill and insert appropriate wall anchors if required
    External Power Supply Installation

  4. Remove cover from mounting box
    External Power Supply Installation

  5. Fix mounting box to wall
    External Power Supply Installation

  6. Pass mains (230V) power supply into mounting box via grommet and terminate accordingly
    External Power Supply Installation

  7. Reinstall cover of mouting box and ensure sealed.
    Tighten grommet to ensure snug around cables
    External Power Supply Installation

Note: Power supply should be secured via current breaker before the external supply (not included)

Faucet Installation

  1. Install 1/2” angel valve
    Faucet Installation

  2. Flush lines thoroughly
    Faucet Installation

  3. Fit mounting screw into base of faucet
    Faucet Installation

  4. Fit connection hose to base of faucet
    Faucet Installation

  5. Fit stainless mounting plate (top) and gasket (top) between basin and facet. Pass mounting screw, hose and electrical connections through vanity
    Faucet Installation

  6. Fit gasket (bottom), mounting plate and hex nut
    Faucet Installation

  7. Fit filter into angel valve and connect hoses
    Faucet Installation

  8. Connect external power (24V outlet) supply to wago connectors on faucet (Note polarity: brown to brown, white to white).
    Faucet Installation

  9. Turn angel valve on and check all connections
    Faucet Installation

  10. Do not come within active range

  11. Turn power supply on.
    It is necessary, for the proper function, to keep the unit under constant voltage (don´t connect the power supply unit behind the switch into the light circuit)

  12. Once power turned on, faucet will automatically adjust sensing range during first 10 seconds. The LED on sensor will continually flash, do not come in active range during this time.
    Faucet Installation

Important

  • Pipework is required to be flushed thoroughly prior to faucet and solenoid installation.
    Foreign debris may reduce level of flow and in some cases damage the solenoid valve.

  • The senor of the faucet must not be obstructed.

  • Avoid positioning reflective objects or surfaces in front of the faucet sensor. This can cause false activation i.e. mirrors opposite faucet. With wall mounted faucets pay particular attention to the distance between the bottom of the basin and the faucet (minimum of 300mm) and the location and material of the basin waste (avoid mounting directly over the waste and/or choose non reflective options).

  • All plumbing and electrical installation must be carried out by a qualified person and in accordance with applicable codes and regulations.

Note: If you require to modify any of the factory settings please request the Sanela remote SLD03.

Activation Range Time Delay Hygienic Flush

AUTOMATIC
| FACTORY SETTINGS 0,25 s.
Time Delay| HYGIENIC FLUSH INTERVAL FACTORY SETTING OFF
| HYGIENIC FLUSH DURATION
FACTORY SETTINGS 5s
SLD 03: 0,1 – 0,3 m| SLD 03: 0,25 – 7,75 s.| SLD 03: ON/OFF| SLD 03:6-168 h

Maintenance

  • It is recommended that the solenoid valve and all filters be inspected for foreign debris and cleaned annually (more frequently if necessary)
  • Clean faucet regularly using soapy water and a soft cloth or wet sponge
  • DO NOT clean faucet with any abrasive material or chlorine/acid based cleaning product. This may damage the filter of the infrared sensor and/or the finishing of the faucet.

Troubleshooting

Symptom Possible Cause Corrective Action

No water flow – is LED on sensorflashing red when hands are within active range?| a.    Water supply
b.    Water connections
c.    Filter is clogged
d.    Faulty solenoid| a.    Ensure water at source
b.    Ensure connections
c.    Clean filter (angel valve and solenoid)
d.    Replace solenoid
No water flow – LED on sensor NOT flashing when hands are within active range.| a.    Power supply
b.    Power connections to faucet (wago connectors)
c.    IR sensor damaged
d.    Faulty IR sensor| a.    Ensure power at source
b.    Check all connections and polarity
c.    Replace IR sensor filter
d.    Replace IR sensor
Water doesn’tstop flowing| a.    Dirty IR sensor
b.    Obstruction in detection zone
c.    Water drop on sensor eye
d.    Ghost sensing due to reflection
e.    Debris in solenoid| a.    Clean IR sensor
b.    Remove obstruction
c.    Wipe sensor
d.    Remove reflective surface or reposition
e.    Clean and/or replace solenoid
Reduced flow rate| a.    Filter clogged
b.    Aerator clogged
c.    Water supply| a.    Clean filter
b.    Clean aerator
c.    Check pressure / flow at source

Supreme Comprehensive Warranty

Your Supreme sensor tap is fully guaranteed against defective materials and faulty workmanship commencing from the date of sale (according to SPL’s records), subject to it being installed and maintained in accordance with the manufacturer’s instructions.
SPL (2021) Limited warrants that should any part of the sensor tap fail within the given warranty period (24 months), it will be remedied by SPL. The tap should be returned to SPL (2021) Limited for all warranty claims. The cost of cartage will be payable by the customer.

This warranty excludes:

  • Incorrect installation, or installation that does not specifically follow the installation guidelines supplied

  • Failure to follow manufacturer’s maintenance instructions

  • Damage/Failure resulting from:

    • the use of non-authorised parts
    • authorised parts not installed in accordance with the manufacturer’s instructions
    • accidental damage, negligent use, misuse, vandalism, neglect
    • damage caused either directly or indirectly by external sources (incorrect power supply, natural disaster, or insect infestation)
  • Water ingress caused by property maintenance or flooding

  • Negligent cleaning practices (water ingress, harmful chemical etc)
    The above includes consequential damage to any other goods, furnishings, or property.

  • Normal wear and tear and consumable parts (batteries etc)

  • This warranty does not displace any statutory warranty in relation to the dispenser but any liability of SPL (2021) Limited under any statutory warranty will be limited to a replacement or repair of the dispenser or payment of the cost of such replacement or repair at the sole discretion of SPL (2021) Limited

Note:

  • Warranty only extends to products purchased and installed in New Zealand.
  • Contamination or poor water quality is not covered by product warranty.
  • Damage to solenoid caused by inadequate flushing or excess water pressure is not covered by the product warranty.

SPL Limited PO Box 437, Cambridge 3450 New Zealand

p. +64 7 823 5790
e. office@splwashrooms.co.nz
Company logo