SANELA AUSTERE Sensor Tap Installation Guide

May 15, 2024
SANELA

SANELA-AUSTERE-Sensor-Tap-FIG-18 SANELA AUSTERE Sensor Tap

Specifications

  • Finish: Tempered Water
  • B Cold and pre-mixed water
  • Power Supply: 230V input
  • Control Operating Voltage : 24V output (to faucet)
  • Active Range : Hands within active range, water flows; Hands removed from active range, water stops
  • Recommended Pressure: Operating pressure range
  • Rate of Flow: After 5 mins of use water will stop
  • Water Inlet Dimensions: Standard faucet components

General Information

  • Designed for indoor use only. Do not be exposed to elements of nature.
  • All plumbing and electrical connections must be made under AUS / NZ standards.

Warnings

  • Read all instructions before attempting to install this system. It is recommended a qualified & registered plumber completes the installation.
  • Ensure pipe work is thoroughly flushed before installing the solenoid assembly. Solenoid components are susceptible to debris and require additional flushing compared to a standard plumbing fixture.
  • Consideration should be given to any regulations relating to an air gap, an air break, or a double-check valve to protect against backflow.

Operating Instructions and Parts Manual
Please read carefully before attempting to assemble, install, operate, or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference.

Sanela Austere Sensor Tap
Sensor-activated tapware for cold and pre-mixed water. High-quality electronics combined with elegant aesthetics.

Specifications

SANELA-AUSTERE-Sensor-Tap-FIG-19

Planning

  • Ensure an appropriate piping design (sizing etc). This will eliminate issues arising from flow, pressure, and water hammering.
  • Where appropriate install necessary filters, water hammering arrestors, and water pressure-reducing valves (recommended pressure 1 to 6 bar). This will minimize future maintenance.
  • Install the angel valve to enable ease of future maintenance.

Tempered Water

  • An appropriate thermostatic mixing valve (TMV3) should be installed to ensure a safe regulated water temperature. These are available from SPL – SST THERMO VALVE

Components

SANELA-AUSTERE-Sensor-Tap-FIG-1

Standard Functions

SANELA-AUSTERE-Sensor-Tap-FIG-2

External Power Supply Installation

SANELA-AUSTERE-Sensor-Tap-FIG-3

Important

  • To be installed by all NZ electrical regulations. It must be carried out by a qualified professional.

Positioning of the mounting box should be 500mm from the floor and consider:

  1. Moisture ingress due to plumbing fault
  2. Ongoing maintenance and accessibility

The mounting box can be surface mounted or within the service or ceiling cavity.

  1. Ensure the mains power supply is off
  2. Mark mounting point(s) on the surface.SANELA-AUSTERE-Sensor-Tap-FIG-4
  3. Drill and insert appropriate wall anchors if required
  4. Remove the cover from the mounting boxSANELA-AUSTERE-Sensor-Tap-FIG-5
  5. Fix the mounting box to the wall
  6. Pass mains (230V) power supply into the mounting box via grommet and terminate accordinglySANELA-AUSTERE-Sensor-Tap-FIG-6
  7. Reinstall the cover of the mounting box and ensure sealed. Tighten the grommet to ensure snug around the cables Note: The power supply should be secured via the current breaker before the external supply (not included)

Faucet Installation

SANELA-AUSTERE-Sensor-Tap-FIG-8

  • Install 1/2” angel valveSANELA-AUSTERE-Sensor-Tap-FIG-9

  • Flush lines thoroughly

  • Fit mounting screw, o-ring, and rubber gasket SANELA-AUSTERE-Sensor-Tap-FIG-10

  • Pass mounting screw, hose, and electrical connections through the vanity.

  • Fit mounting plate and hex nuts
    SANELA-AUSTERE-Sensor-Tap-FIG-11

  • Fit filter into angel valve

  • Note the arrow on the solenoid valve SANELA-AUSTERE-Sensor-Tap-FIG-12

  • Fit connection hose and solenoid. Note 8

  • Connect the faucet to the solenoid valve SANELA-AUSTERE-Sensor-Tap-FIG-13

  • Connect external power (24V outlet) supply to Wago connectors on the faucet. (Note polarity: brown to brown, white to white)

  • Turn the angel valve on and check all connections SANELA-AUSTERE-Sensor-Tap-FIG-14

  • Do not come within the active range

  • Turn the power supply on
    It is necessary, for the proper function, to keep the unit under constant voltage (don´t connect the power supply unit behind the switch into the light circuit)SANELA-AUSTERE-Sensor-Tap-FIG-14

  • Once power is turned on, the faucet will automatically adjust the sensing range during the first 10 seconds.
    The LED on the sensor will continually flash and do not come in active range during this time.

Important

  • Pipework is required to be flushed thoroughly before faucet and solenoid installation. Foreign debris may reduce the level of flow and in some cases damage the solenoid valve.
  • The senor of the faucet must not be obstructed.
  • Avoid positioning reflective objects or surfaces in front of the faucet sensor. This can cause false activation i.e. mirrors opposite faucet. With wall-mounted faucets pay particular attention to the distance between the bottom of the basin and the faucet (minimum of 300mm) and the location and material of the basin waste(avoid mounting directly over the waste and/or choose nonreflective options).
  • All plumbing and electrical installation must be carried out by a qualified person and under applicable codes and regulations.

Note : If you require to modify any of the factory settings please request the Sanela remote SLD03.

SANELA-AUSTERE-Sensor-Tap-FIG-16

Maintenance

  • It is recommended that the solenoid valve and all filters be inspected for foreign debris and cleaned annually (more frequently if necessary)
  • Clean the faucet regularly using soapy water and a soft cloth or wet sponge
  • DO NOT clean the faucet with any abrasive material or chlorine/acid-based cleaning product. This may damage the filter of the infrared sensor and/or the finishing of the faucet.

Troubleshooting

SANELA-AUSTERE-Sensor-Tap-FIG-17

Warranty

Supreme Comprehensive Warranty
Your Supreme sensor tap is fully guaranteed against defective materials and faulty workmanship commencing from the date of sale (according to SPL’s records), subject to it being installed and maintained by the manufacturer’s instructions.

SPL (2021) Limited warrants that should any part of the sensor tap fail within the given warranty period (24 months), it will be remedied by SPL. The tap should be returned to SPL (2021) Limited for all warranty claims. The cost of cartage will be payable by the customer.

This warranty excludes

  • Incorrect installation, or installation that does not specifically follow the installation guidelines supplied
  • Failure to follow the manufacturer’s maintenance instructions
  • Damage/Failure resulting from:
    • the use of non-authorised parts
    • authorized parts not installed under the manufacturer’s instructions
    • accidental damage, negligent use, misuse, vandalism, neglect
    • damage caused either directly or indirectly by external sources (incorrect power supply, natural disaster, or insect infestation)
  • Water ingress caused by property maintenance or flooding
  • Negligent cleaning practices (water ingress, harmful chemical,s etc)

The above includes consequential damage to any other goods, furnishings, or property.

  • Normal wear and tear and consumable parts (batteries etc)
  • This warranty does not displace any statutory warranty concerning the dispenser but any liability of SPL (2021) Limited under any statutory warranty will be limited to a replacement or repair of the dispenser or payment of
    the cost of such replacement or repair at the sole discretion of SPL (2021) Limited

SPL Limited
PO Box 437, Cambridge 3450 New Zealand
p. +64 7 823 5790
[email protected]
splwashrooms.co.nz