SANELA SPARTAN PIEZO Sensor Tap Installation Guide

May 15, 2024
SANELA

SANELA-logo

SANELA SPARTAN PIEZO Sensor Tap

Specifications

  • Finish: Tempered Water
  • Water Temperature: Cold and pre-mixed water
  • Power Supply: 230V input, 24V output
  • Control: Soft touch piezo button
  • Operating Voltage: 24V
  • Active Range: 10 seconds
  • Recommended Pressure: Operating pressure range
  • Rate of Flow: 10L
  • Water Inlet: G 1/2 size
  • Dimensions: Refer to manual for detailed dimensions

Product Usage Instructions

External Power Supply Installation

  1. Ensure mains power supply is off.
  2. Mark mounting point(s) on the surface.

Faucet Installation

  1. Install 1/2 angle valve.
  2. Flush lines thoroughly with 10L.

FAQ

  • Symptom: No water flow when Piezo activated?
  • Possible Cause: Check external power supply connection and water inlet.
  • Corrective Action: Ensure proper installation of external power supply and check water flow.

Installation & maintenance instructions.

General Information

  • Designed for indoor use only. Do not expose to elements of nature.
  • All plumbing and electrical connection must be made in accordance with AUS / NZ standards.

Warnings

  • Read all instructions before attempting to install this system. It is recommended a qualified & registered plumber completes the install.
  • Ensure pipe work is thoroughly flushed before installing the faucet (internal solenoid). Solenoid components are susceptible to debris and require additional flushing compared to a standard plumbing fixture.
  • Consideration should be given to any regulations relating to an air gap, an air break or double check valve to protect against back flow.

Operating Instructions and Parts Manual

Please read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference.
Sanela Spartan Piezo Sensor Tap
Sensor activated tapware for cold and pre-mixed water. High quality electronics combined with elegant aesthetics.

specifications

SANELA-SPARTAN-PIEZO-Sensor-Tap- \(15\)

Planning

  • Ensure an appropriate piping design (sizing etc). This will eliminate issues arising from flow, pressure and water hammering.
  • Where appropriate install necessary filters, water hammering arrestors and water pressure reducing valves (recommended pressure 1 to 6 bar). This will minimise future maintenance.
  • Install the angle valve to enable ease of future maintenance.

Tempered Water

An appropriate thermostatic mixing valve (TMV3) should be installed to ensure a safe regulated water temperature. These are available from SPL – SST THERMO VALVE

Components

SANELA-SPARTAN-PIEZO-Sensor-Tap- \(1\)

1 Hex nut
2 Internal solenoid valve
3 Filter
5 Connection hose
6 Gasket (top)
7 Mounting plate (top S/S)
8 Mounting plate (bottom)
9 Mounting screw
10 Gasket (bottom)

Standard Functions

SANELA-SPARTAN-PIEZO-Sensor-Tap- \(2\) SANELA-
SPARTAN-PIEZO-Sensor-Tap- \(3\)

External Power Supply Installation

Input 230V / 50 Hz
Output 24 V DC
IP rating IP 55
Operating temperature 5°C – 40°C
Rated power 10W

SANELA-SPARTAN-PIEZO-Sensor-Tap- \(4\)

Important
To be installed in accordance with all NZ electrical regulations. It must be carried out
by a qualified professional.
Positioning of the mounting box should be 500mm from the floor and consider:

  1. Moisture ingress due to plumbing fault
  2. Ongoing maintenance and accessibility

The mounting box can be surface mounted or within the service or ceiling cavity.

SANELA-SPARTAN-PIEZO-Sensor-Tap- \(5\)

  1. Ensure mains power supply is off
  2. Mark mounting point(s) on surface
  3. Drill and insert appropriate wall anchors if required
  4. Remove cover from mounting boxSANELA-SPARTAN-PIEZO-Sensor-Tap- \(6\)
  5. Fix mounting box to wall
  6. Pass mains (230V) power supply into mounting box via grommet and terminate accordinglySANELA-SPARTAN-PIEZO-Sensor-Tap- \(7\)
  7. Reinstall cover of mounting box and ensure sealed. Tighten grommet to ensure snug around cables
    Note: Power supply should be secured via current breaker before the external supply (not included)

Faucet Installation

  1. Install 1/2” angle valve

  2. Flush lines thoroughlySANELA-SPARTAN-PIEZO-Sensor-Tap- \(9\)

  3. Fit mounting screw into base of faucet

  4. Fit connection hose to base of faucetSANELA-SPARTAN-PIEZO-Sensor-Tap- \(10\)

  5. Fit stainless mounting plate (top) and gasket (top) between basin and faucet. Pass mounting screw, hose and electrical connections through vanity

  6. Fit gasket (bottom), mounting plate (bottom) and hex nutSANELA-SPARTAN-PIEZO-Sensor-Tap- \(11\)

  7. Fit filter into angle valve and connect hoses

  8. Connect external power (24V outlet) supply to wago connectors on faucet
    (Note   polarity: brown to brown, white to white).SANELA-SPARTAN-
PIEZO-Sensor-Tap- \(12\)

  9. Turn angle valve on and check all connections

  10. Turn power supply on. It is necessary, for the proper function, to keep the unit under constant voltage (don´t connect the power supply unit behind the switch into the light circuit)

SANELA-SPARTAN-PIEZO-Sensor-Tap- \(13\)

Important

  • Pipework is required to be flushed thoroughly prior to faucet and solenoid installation. Foreign debris may reduce level of flow and in some cases damage the solenoid valve.
  • All plumbing and electrical installation must be carried out by a qualified person and in accordance with applicable codes and regulations.
    Note: If you require to modify factory settings please request the Sanela remote SLD04.

Time Delay

Maintenance

  • It is recommended that the solenoid valve and all filters be inspected for foreign debris and cleaned annually (more frequently if necessary)
  • Clean faucet regularly using soapy water and a soft cloth or wet sponge
  • DO NOT clean faucet with any abrasive material or chlorine/acid based cleaning product. This may damage the finishing of the faucet.

Troubleshooting

Symptom Possible Cause Corrective Action
No water flow when Piezo activated?
  • Water supply
  • Water connections
  • Filter is clogged
  • Power supply
  • Power connectors to faucet (wago connectors)
  • Faulty solenoid
  • Faulty Piezo

|

  • Ensure water at source
  • Ensure connections
  • Clean filter (angle valve and solenoid)
  • Ensure power at source
  • Check all connections and polarity
  • Replace solenoid
  • Replace Piezo

Water doesn’t stop flowing| Debris in solenoid|  Clean and/or replace solenoid
Reduced flow rate|

  • Filter clogged
  • Aerator clogged
  • Water supply

|

  • Clean filter
  • Clean aerator
  • Check pressure / flow at source

Supreme Comprehensive Warranty

Your Supreme sensor tap is fully guaranteed against defective materials and faulty workmanship commencing from the date of sale (according to SPL’s records), subject to it being installed and maintained in accordance with the manufacturer’s instructions.
SPL (2021) Limited warrants that should any part of the sensor tap fail within the given warranty period (24 months), it will be remedied by SPL. The tap should be returned to SPL (2021) Limited for all warranty claims. The cost of cartage will be payable by the customer.

This warranty excludes:

  • Incorrect installation, or installation that does not specifically follow the installation guidelines supplied
  • Failure to follow manufacturer’s maintenance instructions
  • Damage/Failure resulting from:
    • the use of non-authorised parts
    • authorised parts not installed in accordance with the manufacturer’s instructions
    • accidental damage, negligent use, misuse, vandalism, neglect
    • damage caused either directly or indirectly by external sources (incorrect power supply, natural disaster, or insect infestation)
  • Water ingress caused by property maintenance or flooding
  • Negligent cleaning practices (water ingress, harmful chemical etc)

The above includes consequential damage to any other goods, furnishings, or property.

  • Normal wear and tear and consumable parts (batteries etc)
  •  This warranty does not displace any statutory warranty in relation to the dispenser but any liability of SPL (2021) Limited under any statutory warranty will be limited to a replacement or repair of the dispenser or payment of the cost of such replacement or repair at the sole discretion of SPL (2021) Limited

Note:

  • Warranty only extends to products purchased and installed in New Zealand.
  • Contamination or poor water quality is not covered by product warranty.
  • Damage to solenoid caused by inadequate flushing or excess water pressure is not covered by the product warranty.

SPL Limited PO Box 437, Cambridge 3450 New Zealand