COL50 Bluetooth Control Box

BL1 end plate kit with cable through: Top plate dimensions:

Motor cable

Bottom plate dimensions:

Hand control cable

Hand control cable
Please notice the thickness of the bottom plate is 12 mm . The thickness of the bottom plate without connections is 10 mm . Bottom plate dimensions:
Motor cable
Drawing no .: 0801263-A
BL1 Mounting guidelines: · BL1 is for use in push applications, and can be mounted in both directions (smallest profile down, or up) .
Note: The cable outlet can be positioned at the top (smallest profile) . If the option with integrated cable is chosen, the cable outlet can also be positioned at the bottom (biggest profile) . · It is very simple to mount the BL1 in the application using the 4 mounting holes in both endplates . · Use 4 self-tapping screws, in each end, for mounting to the application . Use EJOT PT type DG Ø8, screw depth must be min . 30 mm in aluminium profile . Screw torque: 15 – 17 Nm . · If the column has been loosened from the application, it is very important that the self-tapping screws are mounted in the same thread, to ensure the same strength in the thread . Therefore we recommend that the screws are loosened no more than 1 or 2 times .
Page 81 of 264

0.8

Mounting holes 0.6
Mounting holes Mounting of BL1 with cable through:
Mounting holes

Mounting holes Drain hole

Drain hole

Mounting holes

Drawing no .: 0807000-1

Mounting holes Drain hole

Mounting holes

Drain hole

Mounting holes Page 82 of 264

Drawing no .: 0807001-1

Recommendations
· The mounting plate in the application must cover the entire top plate of the BL1 and be strong enough to carry the load . · Remember to secure the cable mounted in the top of the column to the application, so that it cannot be pulled out of the column .
We recommend to use LINAK Cable: – Lock kit for BL1 with motor cable: 0808040 – Lock kit for BL1 with hand control cable through: 0808046 Use only the screws included in the kit . · For motor cable mounted at the top, use the long screw with the coarse thread . Screw torque 1 .7 Nm . · For motor cable mounted at the bottom and for cable through, use the short screw with the fine thread . Screw torque 2 .7 Nm . · Electro Static Discharges! There is no electrical connection through the length of the BL1 column . Therefore, to avoid ESD issues, consider external potential alignment between the top and bottom of the bed frame . To connect for further earth wiring in the application, use an appropriate ø8 mm cable shoe under one of the 8 mm screws at both the top plate and the bottom plate . · Remember to mount the blind plugs in the top plate if the motor cable is connected from the bottom plate to ensure the IPX6 protection .

When mounting more than one BL1 you need to consider the fixation: Fixed pivot point

Moveable pivot point

Example 1 .

Example 2 .

Fixed pivot point

Fixed pivot point

The reason why it is important only to fix one column, is that the columns will not move exactly in parallel ­ even if you have positioning such as hall . If more than one column is fixed it can lead to dangerous situations .

If you have a trend/anti-trend function in your application, you need to mount one or more BL1s with a slider . Having sliders prevents the column from bending as illustrated below .

Page 83 of 264

2. LC3 (MEDLINE® CARELINE® )

The LC3 2-stage and 3-stage set the standard for vertical lifting columns to high-end medical applications . This compact lifting column fulfils the market requirements for a solid and stable lifting column .

Usage:

· Duty cycle: 10%, 2 minutes continuous use followed by 18 minutes not in use

· Operation temperature:

+5 °C to + 40 °C

· Storage temperature:

-40 °C to + 70 °C

· Compatibility:

Compatible with LINAK control boxes .

Please contact LINAK .

· Relative humidity:

20% to 80% – non-condensing

· Atmospheric pressure:

700 to 1060 hPa

· Meters above sea level:

Max . 3000 meters

· Approvals:

IEC 60601-1

IEC 60601-1-6

ANSI/AAMI ES60601-1

CAN/CSA-C22 .2 No . 60601-1

LC3 mounting guidelines LC3 is for use in push or pull applications and can be mounted in both directions ­ largest profile down or largest profile up . LC3 must be specified for specific mounting direction .
Mounting direction according to item number nomenclature .

Observe no drain holes

Top plate up IPX4

Top plate down

Observe no drain holes
IPX4
IPX6

Observe drain holes

Observe no drain holes

IPX6 is only available when LC3 is mounted with the largest profile up . IPX6 is only applicable when the LC3 column is fully retracted . Note: The cable outlet for motor connection can be positioned at the top (smallest profile) or from the side of the column .

Page 84 of 264

LC3 mounting guidelines
If you want to use the column with a high off-center load, we recommend that you install the weight in one of the 3 ways illustrated by the green symbols . It is not recommended to install the weight on the opposite side of the mechanical endstop as illustrated with the red symbol . This installation can create an uneven movement when the lifting column reaches the endstop position .

Mechanical endstop

Use 4 pcs . M10 8 .8 screws, in each end, for mounting to the application . The screw depth must be min . 20 mm and max . 30 mm in aluminum profile . Screw torque: 35 Nm . LC3 3-Stage

15 mm distance to thread

Screw depth min . 20 mm

3 mm distance to thread

Mounting holes, top

Mounting holes, bottom

Page 85 of 264

Drawing no .: 1002W9005

Use 4 pcs . M10 8 .8 screws, in each end, for mounting to the application . The screw depth must be min . 20 mm and max . 30 mm in aluminum profile . Screw torque: 35 Nm . LC3 2-Stage

15 mm distance to thread

Screw depth min . 20 mm

3 mm distance to thread

Mounting holes, top

Mounting holes, bottom

Drawing no .: 1002W9008
Notice that the cable plug must be mounted correctly . The cable slot must fit into the socket .
Remember to secure the cable mounted in the top of the column to the application, so that it cannot be pulled out of the column . We recommend to use LINAK Cable: · Lock kit for minifit cable: 1002W8136-A . · Lock kit for hand control cable through: 1002W8137-A
Use only the screws included in the kit . Screw torque: 2 Nm
The cables coming out of the side of the column should follow below guidelines . The internal radius should not be more than 3 times the outer dimension ­ OD – of the cable . For instance if the outer cable dimension is Ø7, the internal radius of the maximum cable bending is 21 mm .

· LC3 3-stage – protective grounding cable LC3 has potential equalization between top and bottom plate but the middle profile is not grounded .
· It is recommended to use screws with thread-lock adhesive · Screws of high quality steel 8 .8 or 10 .9 must be used to secure safe mounting of the LC3 to the application .
Page 86 of 264

Cable connections overview 3-stage is used as examples but variants are also applicable for 2-stage . This overview shows all possible cable connections, but please notice that some variants are upon request .

Variant

Top plate
Drawing no .:1002W9005

Side entry
Drawing no .:1002W9005

T000

Connections T001

5: Motor

Connections T100

5: Motor

Including protective grounding cable

Connections T200

5: Motor 6: Minifit through

3: Minifit through

Connections

5: Motor 6: HB through

3: HB through
Page 87 of 264

T030

Connections T040

5: Motor 6: Mains through 1
Female connection top entry, male connection side entry

3: Mains through 1 Female connection top entry, male connection side entry

Connections T101

5: Motor 6: Mains through 2
Male connection top entry, female connection side entry

3: Mains through 2 Male connection top entry, female connection side entry

Connections

5: Motor 6: Minifit through

3: Minifit through
Page 88 of 264

Including protective grounding cable

T201

Connections T031

5: Motor 6: HB through

3: HB through

Including protective grounding cable

Connections T041

5: Motor 6: Mains through 1
Female connection top entry, male connection side entry

3: Mains through 1 Female connection top entry, Including protective grounding cable male connection side entry

Connections

5: Motor 6: Mains through 2
Male connection top entry, female connection side entry

3: Mains through 2 Male connection top entry, Including protective grounding cable
female connection side entry

Page 89 of 264

T110

Connections T120

5: Motor 6: Minifit through (top) 7: Minifit through (top)

3: Minifit through (side) 4: Minifit through (side)

Connections T220

5: Motor 6: HB through 7: Minifit through

3: HB through 4: Minifit through

Connections

5: Motor 6: HB through (top) 7: HB through (top)

3: HB through (side) 4: HB through (side)

Page 90 of 264

T130

Connections T140

5: Motor 6: Mains through 1
Female connection top entry, male connection side entry 7: Minifit through

3: Mains through 1 Female connection top entry, male connection side entry
4: Minifit through

Connections T230

5: Motor 6: Mains through 2
Male connection top entry, female connection side entry 7: Minifit through

3: Mains through 2 Male connection top entry, female connection side entry
4: Minifit through

Connections

5: Motor

6: Mains through 1

3: Mains through 1

Female connection top entry,

Female connection top entry,

male connection side entry

male connection side entry

7: HB through

4: HB through
Page 91 of 264

T240

Connections S300

5: Motor 6: Mains through 2
Male connection top entry, female connection side entry 7: HB through

3: Mains through 2 Male connection top entry, female connection side entry
4: HB through

Connections S400

3: Motor supply

Connections

3: Motor supply
Page 92 of 264

S500

Connections S301
Connections S401
Connections

3: Motor supply

3: Motor supply

Including protective grounding cable

3: Motor supply

Including protective grounding cable

Page 93 of 264

S501
Connections S310

3: Motor supply

Including protective grounding cable

Connections S320

6: Minifit through

3: Motor supply 4: Minifit through

Connections

6: HB through

3: Motor supply 4: HB through

Page 94 of 264

S410

Connections S420

6: Minifit through

3: Motor supply 4: Minifit through

Connections S510

6: HB through

3: Motor supply 4: HB through

Connections

6: Minifit through

3: Motor supply 4: Minifit through

Page 95 of 264

S520

Connections S330

6: HB through

3: Motor supply 4: HB through

Connections S340

6: Mains through 1 Female connection top entry, male connection side entry

3: Motor supply 4: Mains through 1
Female connection top entry, male connection side entry

Connections

6: Mains through 2 Male connection top entry, female connection side entry

3: Motor supply 4: Mains through 2
Male connection top entry, female connection side entry

Page 96 of 264