LINAK TD5 TWINDRIVE Standard Comfort Beds User Manual
- June 11, 2024
- LINAK
Table of Contents
- Preface
- Important information
- Safety instruction
- **Misc. on the TWINDRIVE® TD5 Standard system
- Description of the TWINDRIVE® TD5 Standard system
- Mounting the TD5 Standard
- Start-up (How to pair a Bluetooth® connection)
- TD5 Twist Bracket
- Functional description
- Main groups of disposal
- Disposal of batteries
- DRAWING APPENDIX
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TD5 TWINDRIVE Standard Comfort Beds
User Manual
Preface
Dear User,
We are delighted that you have chosen a product from LINAK®.
LINAK systems are high-tech products based on many years of experience in the
manufacture and development of actuators, electric control boxes, controls and
chargers.
This User Manual does not address the end-user. It is intended as a source of
information for the manufacturer of the equipment or system only, and it will
tell you how to install, use and maintain your LINAK electronics. It is the
responsibility of the manufacturer of the end-use product to provide a User
Manual where relevant safety information from this manual is passed on to the
end-user.
We are sure that your LINAK product/system will give you many years of
problem-free operation.
Before our products leave the factory they undergo full function and quality
testing. Should you nevertheless experience problems with your LINAK
product/system, you are always welcome to contact your local dealer.
LINAK subsidiaries and some distributors situated all over the world have
authorised service centres, which are always ready to help you.
LINAK provides a limited warranty on its products. This warranty is, however,
subject to correct use in accordance with the specifications, maintenance
being done correctly, and any repairs being carried out at a service centre,
which is authorised to repair LINAK products. You can review the full terms of
the LINAK warranty on the LINAK website
www.linak.com/warranty.
Changes in installation and use of LINAK products/systems can affect their
operation and durability. The products are not to be opened by unauthorised
personnel.
The User Manual has been written based on our present technical knowledge. We
are constantly working on updating the information and we therefore reserve
the right to carry out technical modifications.
LINAK A/S
Important information
Important information on LINAK® products can be found under the following
headings:
Warning!
Failure to comply with these instructions may result in accidents involving
serious personal injury.
Failing to follow these instructions can result in the product being damaged
or being destroyed.
Safety instruction
General
Safe use of the system is possible only when the operating instructions are
read completely and the instructions contained are strictly observed.
Failure to comply with instructions marked with the ”NOTE” symbol may result
in serious damage to the system or one of its components.
It is important for everyone who is to connect, install, or use the
systems to have the necessary information and access to this User Manual.
Follow the instructions for mounting – risk of injury if these instructions
are not followed.
The appliance is not intended for use by young children or infirm
persons without supervision.
If there is visible damage on the product it must not be installed.
Note that during construction of applications, in which the actuator is
to be fitted, there must be no possibility of personal injury, for example
squeezing of fingers or arms.
Assure free space for movement of the application in both directions to
avoid blockade.
Assure free space for movement of application in both directions to
avoid blockade.
** The appliance is only to be used with the power supply unit provided
with the appliance.
Safety issues
** The builder of the equipment shall ensure that the use of the component
complies with relevant standards – like the Machine Directive. Care must be
taken to avoid squeezing of cables as it can cause movement of the system!
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation
-
Statement – for all intentional and unintentional radiators:
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. -
Statement for digital devices for Class B:
NOTE: This equipment has been tested and found to comply with the limits for a Class B diwgital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and the receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/ TV technician for help.
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s).
Operation is subject to the following two conditions:
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
Labeling Requirements:
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du
Canada.
Before installation, de-installation or troubleshooting:
- Stop the TD5 Standard.
- Disconnect the power.
- Relieve the TD5 of any loads, which may be released during the work.
Before start-up:
-
Make sure that the system has been installed as instructed in this User Manual.
-
Make sure that the voltage is correct before the system is connected to the mains.
(See TD5 label in the appendix). -
System connection. The individual parts must be connected before connecting to the mains.
During operation:
- If the control box makes unusual noise or smells, switch off the mains voltage immediately.
- Take care that the cables are not damaged.
- Unplug the mains cable on mobile equipment before it is moved.
Misc:
The actuator system has a sound level below 55 dB(A) in typical applications.
Updated manuals and declarations can always be found here:
www.linak.com/HOMELINE
Electromagnetic fields (EMF):
This LINAK appliance complies will all standards regarding electromagnetic
fields (EMF). If handled properly and according to instructions in this user
manual, the appliance is safe to use based on scientific evidence available
today.
Only for EU markets
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
Only for Non EU markets
Persons who do not have the necessary experience or knowledge of the
product/products must not use the product/products. Besides, persons with
reduced physical, sensory or mental abilities must not use the product/
products, unless they are under surveillance or they have been thoroughly
instructed in the use of the apparatus by a person who is responsible for the
safety of these persons.
Moreover, children must be under surveillance to ensure that they do not
play with the product.
Misuse
Do not overload the actuators – this can cause danger of personal injury
and damage to the system.
Do not use the actuator system for lifting persons. Do not sit or stand
on a table while operating – risk of personal injury.
** Do not use the system in environments other than the intended indoor
use.
Repairs
Repairs In order to avoid the risk of malfunction, all HOMELINE® repairs must
only be carried out by authorised LINAK service centres or repairers, as
special tools must be used and special gaskets must be fitted. Products under
warranty must also be returned to authorised LINAK service centres.
Further information on LINAK HOMELINE warranty can be found on the LINAK
website www.linak.com/warranty.
DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY
LINAK A/S**
Smedevwnget 8
DK – 6430 Nordborg
Name and address of the person authorized to compile the relevant technical
documentation:
John Kling. Group Headquarters, Guderup, DK-6430 Nordborg, email
jkl@linak.com
Herewith declares that LINAK Actuators and Actuator Systems comply with the
following parts of the Machinery Directive 2006/42/EC. ANNEX I, Essential
health and safety requirements relating to the design and construction of
machinery.
1.5.1 Electricity supply: Directive 2006/95/EC on the harmonization of the
laws of Member States relating to electrical equipment designed for use within
certain voltage limits.
1.5.10 Radiation, 1.5.11 External radiation: Directive 2004/108/EC on the
approximation of the laws of the Member States relating to electromagnetic
compatibility.
The relevant technical documentation is compiled in accordance with part B of
Annex VII and that this documentation or part hereof will be transmitted by
post or electronically to a reasoned request by the national authorities.
This partly completed machinery must not be put into service until the final
machinery into which it is to be incorporated has been declared in conformity
with the provisions of this Directive, where appropriate.
Date: 2010-01-01
Signature: Jhon Kling
Certification and Regulatory Affairs
**Misc. on the TWINDRIVE® TD5 Standard system
**
This system is a TWINDRIVE system developed for leisure beds and for indoor
use in private homes.
Warranty
This HOMELINE product is subject to warranty pursuant to the terms of LINAK
HOMELINE Warranty Paper, available on the LINAK website
www.linak.com/warranty.
Maintenance
Clean dust and dirt on the outside of the system at appropriate intervals and
inspect them for damage and breaks.
Inspect the connections, cables and plugs and check for correct functioning as
well as fixing points.
The cleaners and disinfectants must not be highly alkaline or acidic (pH value
6-8).
It is not allowed to use solvents for cleaning up.
Max. load running back and leg end motors at the same time in upward direction
is 7000 N on back motor, and 7000 N on leg end motor.
For customers in the US/Canada:
The mains cable for this product has a polarised plug (one blade is wider than
the other). It will only fit in a polarised outlet one way. If it does not fit
fully in the outlet, reverse the plug. If it still does not fit, contact a
qualified electrician to install a proper outlet. Do not change the plug in
any way.
Description of the TWINDRIVE® TD5 Standard system
Each TWINDRIVE® TD5 Standard unit consists of 2 internal motors and a built-in
control box, which makes it a very compact unit. The mains cable is
exchangeable. Only the handset must be paired.
Application of the TWINDRIVE® TD5 Standard system:
Irrespective of the load the Duty cycle: 10 % ~ max. 1 minute at continous use
followed by 9 minutes not in use.
Do not turn on the system if it is not mounted in a bed.
TD5 is a Bluetooth® based system, which means you can use hand controls based
on Bluetooth®.
LINAK® offers a range of compatible hand controls: HC05BL, HC10BL and HC40BL.
Alternatively, the Bed Control App can be downloaded to use a smartphone as
handset.
You can pair eight hand controls to one TD5. You can also pair both hand
controls and app controls to the same TD5 Standard, but only eight controls in
total. If you pair more hand controls than the TD5 Standard can manage, the
first paired hand control will be deleted.
This user manual will give you a detailed description on how to pair your hand
controls with your TD5 Standard.
Mounting the TD5 Standard
Mounting is made by pushing the TD5 unit into the bed bracket and thereafter
slide the closing devices on.
It is IMPORTANT to be completely sure that the closing devices are in place
before using the TD5.
Recommendations
- Mains cable and controls must be ordered separately
- The shaft diameter must be Ø25.2 (+0.3/-0.2) mm
- Always use the cable relief for the mains cable on the TD5 to avoid pulling out the mains cable plug from the TD5 resulting in a malfunction.
- Do not look directly into the light under the bed.
- The default timeout for the Under Bed Light is 30 minutes.
- Do not drive the TD5 system without the closing devices mounted
- The bed brackets must have a smooth surface without burs and welding blops in the area where the TD5 is mounted.
- It is important to turn the key in the direction indicated on the housing. Turning the key in the wrong direction can wreck the inner hex and make mechanical emergency lowering impossible.
- Do not use an electric screwdriver for lowering, use the enclosed hex key on the TD5.
- The TD5 must be in fully retracted position when starting to lifetime simulator.
- Push TD5 unit into bed bracket.
- Slide each closing device on and press it into correct position. IMPORTANT:
Ensure that the closing devices are in place before using the TD5.
Do not drive the TD5 system without the closing devices mounted.
The bed brackets must have a smooth surface without burs and welding blops in
the area where the TD5 is mounted.
Cable strain relief
It is important to use the cable relief on the TD5. By using the relief you
avoid that the mains cable plug is pulled out of the TD5 resulting in a
malfunction.
Depending on the thickness of the cable, you can choose to lead the cable
through all 3 or just around the middle relief.
Start-up (How to pair a Bluetooth® connection)
Getting started
It is possible to pair multiple controls to the TD5 via Bluetooth®.
If only one TD5 is to be paired with the control, ensure that only this TD5 is
in pairing mode.
Pairing your control
- Connect TD5 to mains via mains cable.
- TD5 is in pairing mode for three minutes and Under Bed Light flashes to indicate this.
- Press the two top buttons on LINAK® hand control at the same time.
The Under Bed Light gives one long flash to indicate that the hand control and
the TD5 are paired up.
The TD5 stays in pairing mode and it is possible to connect more controls
using the same procedure.
Note:
Wait 5 seconds after pairing control 1 before you can pair control 2.
To get the system out of pairing mode – simply press any button on an already
paired control.
Allow for the hand control to go to power-saving mode (backlight turns off)
before disconnecting the actuator system from the mains supply.
Otherwise the pairing will not be saved in the hand control.
Pairing your smartphone or tablet
- Enable Bluetooth® on smartphone/tablet.
- Open Bed Control App.
- Connect TD5 to mains via mains cable.
- TD5 is in pairing mode for three minutes and Under Bed Light flashes to indicate this.
- Bed Control App will automatically pair to the closest TD5 in pairing mode. Wait a few seconds to see app confirm completed pairing.
- Smartphone/tablet and TD5 are now paired up. App will display operation page and bed can now be adjusted through app.
Note:
The Bluetooth® pairing mode will stop as soon as the phone is connected. Thus,
we recommend to start pairing the hand control and thereafter the phone to
avoid having to disconnect the power.
Pairing another device later
It is possible to connect another control or a smartphone/tablet to the TD5
later.
- Disconnect TD5 from mains.
- Wait 1 minute.
- Reconnect TD5 to mains to get it in pairing mode again.
- Follow instrutions above to pair other devices.
Previously paired devices will not be deleted until a maximum of 8 devices are paired. Pairing a ninth device will delete the first device paired.
Forced pairing mode
You can also pair a new device by using the forced pairing mode.
- Turn on Under Bed Light.
- Disconnect from mains.
- Wait until Under Bed Light turns off.
- Reconnect TD5 to mains to get it in pairing mode again.
- Press two top buttons on your hand control at the same time.
- Light gives a long flash to indicate that control and TD5 are paired up.
How to unpair one TD5
- Put the TD5 you want to keep paired into pairing mode and pair the hand control.
- Send a command from the hand control and the pairing mode stops.
- The connection between the other TD5 and the hand control is now deleted.
Mechanical emergency lowering
Emergency lowering is meant for lowering the bed if a power failure occurs and
the bed needs to be driven down into horizontal position.
- Disconnect TD5 from mains.
- Take hex key on side of TD5.Underneath the TD5 are two gaps for mechanical lowering.
- Place hex key in gap, one end at a time, and turn hex key in direction indicated by arrow.
It is important to turn the key in the direction indicated on the housing.
Turning the key in the wrong direction can wreck the inner hex and make
mechanical emergency lowering impossible.
Do not use an electric screwdriver for lowering, use the hex key enclosed on
the TD5.
TD5 Twist Bracket
Mounting instructions and parallel tolerance
When bed is horizontal (starting position):
The diameter of the shaft must be Ø25.2 + 0.3 – 0.2 mm
TD5 Twist Bracket – Welding instructions: No bracket or welding outside this area 52” from vertical
axis.The dimension of the bracket including
welding may not exceed 38 mm.
To maintain the correct rotation angle of the head-rest and the foot-rest it
is important that the Twist bracket is mounted and welded according to the
above instructions. Non compliance with the instructions could lead to a
smaller angle of rotation or in a worst case damage the TD5.
If the twist brackets are mounted correctly, 1-2 seconds after activating a
hand control the bed should be adjusted. It gives the optimized mounting of
the TD5 during mounting and the correct angle of the bed.
Functional description
Hand Control HB10 Wireless| | Up – down back motor
Up – down leg motor
Common operation up/down (option)
Light Button
---|---|---
Hand Control HC05 Wireless| | Up – down back motor
Up – down leg motor
Common operation up/down (option)
Light Button
Hand Control HC10 Wireless| | Up – down back motor
Up – down leg motor
Common operation up/down (option)
Light Button
Hand Control HC40BL| | Up – down back motor
Up – down leg motor
Common operation up/down (option)
Light Button
Label for TD5 Standard
Label for HC05BL | Label for HB10BL | Label for HC10BL |
---|---|---|
Label for HC40 FRAME™ StandardLabel for HC40
TWIST™ Standard
Disposal of LINAK products
As LINAK customers often ask us how our products can be disposed of or
scrapped we have prepared this guidance that enables a classification to
different waste fractions for recycling or combustion.
Guidance
We recommend to disassemble our product into as many fractions as possible
at the disposal and try to make it recycable. As examples of main groups
within waste fractions we can mention:
Metal, plastic, cable shoe, combustible waste and collection for recovery.
Some of these main groups can be subdivided, e.g. metal can be divided into
iron, stainless steel and aluminium and alloy steel. Plastic can e.g. be
divided into ABS, PA, PE and PP.
As an example of sorting, please find below a list stating in which recycling
groups the different components of LINAK products ought to be placed:
Product | Components | Recycling group |
---|---|---|
Actuator: | Spindle and motor Plastic housing | |
Cable | Scrap |
Plastic recycling or combustion Cable scrap or combustion
Massage motor:| Plastic housing Cable| Plastic recycling or combustion Cable
scrap or combustion
TWINDRIVE:| PCB
Plastic housing
Cable
Transformer Scrap Batteries
Spindle and motor| Electronics scrap
Plastic recycling or combustion Cable scrap
Recovery Scrap
Handset/Control:| Plasic housing PCB
Batteries| Plastic recycling or combustion Electronics scrap
Recovery
By now almost all our casted plastic parts are supplied with an interior code for plastic type and fibre contents, if any.
Main groups of disposal
Product main groups| Scrap| Cable scrap| Electronics
scrap| 1 Plastic recycling or combustin| Comments
---|---|---|---|---|---
TD5| X| X| X| |
HCO5BL| | | X| X|
HB1OBL| | | X| X|
HC1OBL| | | X| X|
HC4OBL| | | X| X|
Disposal of batteries
Details regarding safe disposal of used and leaking batteries:
Batteries should be disposed in accordance with appropriate federal, state and
local regulations. LINAK recommends that used or leaking batteries are
disposed through the local recycling system. Please do not throw used or
leaking batteries in normal household waste or in nature. This will cause
damage to the enviroment.
How to deal with leaking batteries
Leaking batteries should be disposed as described above.
If leaking batteries are discovered in the product the batteries must be
removed at once to minimise damage to the product. If leaking batteries are
left in the product, it may become defective.
It is recommended to use plastic gloves when handling leaking batteries. The
contents of leaking batteries can cause chemical burns and respiratory
irritation.
If exposed to the contents of a leaking battery, please wash with soap and
water. If irritation persists, please seek medical attention. In case of eye
contact, please flush eyes thoroughly with water for 15 minutes and seek
medical attention.
DRAWING APPENDIX
TWINDRIVE® TD5 Standard system![LINAK TD5 TWINDRIVE Standard Comfort Beds
- Standard system](https://manuals.plus/wp-content/uploads/2023/05/LINAK-TD5
-TWINDRIVE-Standard-Comfort-Beds-Standard-system.png) Hand Control
HC05BLHand Control HC10BLHand Control HB10BLHC40 FRAME™
StandardHC40 TWIST™ Standard LINAK APPLICATION POLICY
The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware, software, technical advice, etc. related to an existing or a new customer application.
LINAK products as defined above are applicable for a wide range of applications within the Medical, Furniture, Desk, and Industry areas. Yet, LINAK cannot know all the conditions under which LINAK products will be installed, used, and operated, as each individual application is unique.
The suitability and functionality of the LINAK product and its performance under varying conditions (application, vibration, load, humidity, temperature, frequency, etc.) can only be verified by testing, and shall ultimately be the responsibility of the LINAK customer using any LINAK product.
LINAK shall be responsible solely that the LINAK products comply with the specifications set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specific LINAK product can be used for the application in question.
FACTORIES
• Denmark
LINAK A/S
Group Headquarters
Tel: +45 73 15 15 15
Fax: +45 74 45 80 48
Fax (Sales): +45 73 15 16 13
www.linak.com| • Denmark
LINAK Profiles
Tel: +45 73 70 95 30
www.linak-profiles.com| • China
LINAK (Shenzhen) Actuator Systems, Ltd.
Tel: +86 755 8610 6656
Fax: +86 755 8610 6990
www.linak.cn
---|---|---
• Slovakia
LINAK Slovakia s.r.o.
Tel: +421 51 7563 444
Fax: +421 517563 410
www.linak.sk| • Thailand
LINAK APAC Ltd.
Tel: +66 33 265 400
www.linak.com| • USA
LINAK U.S. Inc.
Americas Headquarters
Tel: +1 502 253 5595
Fax: +1 502 253 5596
www.linak-us.com
SUBSIDIARIES
• Australia
LINAK Australia Pty. Ltd
Tel: +61 3 8796 9777
Fax: +61 3 8796 9778
www.linak.com.au| • Austria
LINAK Repräsentanz
Österreich (Wien)
Tel: +43 (1) 890 7446
Fax: +43 (1) 890 744615
www.linak.at – www.linak.hu|
• Belgium
LINAK Benelux
(Belgium & Luxembourg)
Tel: +32 (0)9 230 01 09
www.linak.be –
www.fr.linak.be
---|---|---
• Brazil
LINAK Do Brasil Comércio De Atuadores Ltda.
Tel: +55 (11) 2832 7070
Fax: +55 (11) 2832 7060
www.linak.com.br| • Canada
LINAK Canada Inc.
Tel: +1 502 253 5595
Fax: +1 416 255 7720
www.linak-us.com| • China
LINAK (Shenzhen) Actuator Systems, Ltd.
Tel: +86 755 8610 6656
Fax: +86 755 8610 6990
www.linak.cn
• Czech Republic
LINAK C&S s.r.o.
Tel: +42 058 174 1814
Fax: +42 058 170 2452
www.linak.cz – www.linak.sk|
• Denmark – Headquarters
LINAK A/S – Group Headquarters
Tel: +45 73 15 15 15
Fax: +45 74 45 80 48
Fax (Sales): +45 73 15 16 13
www.linak.com| • Denmark – International
LINAK International
Tel: +45 73 15 15 15
www.linak.com
• Denmark – Sales
LINAK DANMARK A/S
Tel: +45 86 80 36 11
Fax: +45 86 82 90 51
www.linak.dk| • Finland
LINAK OY
Tel: +358 10 841 8700
www.linak.fi| • France
LINAK FRANCE E.U.R.L
Tel: +33 (0) 2 41 36 34 34
Fax: +33 (0) 2 41 36 35 00
www.linak.fr
• Germany
LINAK GmbH
Tel: +49 6043 9655 0
Fax: +49 6043 9655 60
www.linak.de| • India
LINAK A/S India Liaison Office
Tel: +91 120 4531797
Fax: +91 120 4786428
www.linak.in| • Ireland
LINAK UK Limited (Ireland)
Tel: +44 (0)121 544 2211
Fax: +44 (0)121 544 2552
+44 (0)796 855 1606 (UK Mobile)
+35 387 634 6554 (Republic of Ireland
Mobile)
www.linak.co.uk
• Italy
LINAK ITALIA S.r.l.
Tel: +39 02 48 46 33 66
Fax: +39 02 48 46 82 52
www.linak.it| • Japan
LINAK K.K.
Tel: 81-45-533-0802
Fax: 81-45-533-0803
www.linak.jp| • Malaysia
LINAK Actuators Sdn. Bhd.
Tel: +60 4 210 6500
Fax: +60 4 226 8901
www.linak.my
• Netherlands
LINAK Benelux
Tel: +31 76 5 42 44 40
www.linak.nl| • New Zealand
LINAK New Zealand Ltd
Tel: +64 9580 2071
Fax: +64 9580 2072
www.linak.no| • Norway
LINAK Norge AS
Tel: +47 32 82 90 90
www.linak.no
• Poland
LINAK Polska
LINAK Danmark A/S (Spólka Akcyjna)
Tel: +48 22 295 09 70/22 295 09 71
www.linak.pl| • Republic of Korea
LINAK Korea Ltd.
Tel: +82 2 6231 1515
Fax: +82 2 6231 1516
www.linak.kr| • Russia
LINAK LLC
Tel: +7 495 780 3161
Fax: +7 495 687 1426
www.linak.ru
• Slovakia
LINAK Slovakia s.r.o.
Tel: +421 51 7563 444
www.linak.sk| • Spain
LINAK Actuadores, S.L.u
Tel: +34 93 588 27 77
Fax: +34 93 588 27 85
www.linak.es| • Sweden
LINAK Scandinavia AB
Tel: +46 8 732 20 00
Fax: +46 8 732 20 50
www.linak.se
• Switzerland
LINAK AG
Tel: +41 43 388 31 88
Fax: +41 43 388 31 87
www.linak.ch –
www.fr.linak.ch
www.it.linak.ch| • Taiwan
LINAK (Shenzhen) Actuator systems Ltd.
Taiwan Representative office
Tel: +886 2 27290068
Fax: +886 2 27290096
www.linak.tw| • Thailand
LINAK APAC Ltd.
Tel: +66 33 265 400
• Turkey
LINAK İth. İhr. San. ve Tic. A.Ş.
Tel: + 90 312 4726338
Fax: + 90 312 4726635
www.linak.com.tr| • United Kingdom
LINAK UK Limited
Tel: +44 (0)121 544 2211
Fax: +44 (0)121 544 2552
www.linak.co.uk| • USA
LINAK U.S. Inc.
North and South American Headquarters
Tel: +1 502 253 5595
Fax: +1 502 253 5596
www.linak-us.com
www.linak-latinamerica.com
DISTRIBUTORS
• Argentina
NOVOTEC ARGENTINA SRL
Tel: 011-4303-8989/8900
Fax: 011-4032-0184
www.novotecargentina.com| • Colombia
MEM Ltda
Tel: +[57] (1) 334-7666
Fax: +[57] (1) 282-1684
www.mem.net.co| • India
Mechatronics Control Equipments India Pvt Ltd
Tel: +91-44-28558484, 85
www.mechatronicscontrol.com
---|---|---
• Qatar
Mechatronics Industrial Equipments
Tel: +974 44581155
Fax: +974 44689135
www.mechatronicsqatar.com| •
Singapore
Servo Dynamics Pte Ltd
Tel: +65 6844 0288
Fax (Sales): +65 6844 0070| • United Arab Emirates
Mechatronics Industrial Equipments LLC
Tel: +971 4 267 4311
Fax: +971 4 267 4312
www.mechatronics.ae
LINAK ® accepts no responsibility for possible errorsor inaccuracies in
catalogues, brochures, and othermaterial. LINAK reserves the right to change
itsproducts without prior notice. LINAK cannot guarantee product availability
and reserves the right todiscontinue the sale of any product.
The user is responsible for determining the suitability of LINAK products for
a specific application. Allsales are subject to the ‘Standard Terms of Sale
andDelivery’, available on LINAK websites.
LINAK and the LINAK logotype are registered trademarks of LINAK A/S. All
rights reserved.
Copyright© LINAK 2020.12 MA-M9-02-778-DLINAK.COM/HOMELINE
References
- HOMELINE: LINAK segment - actuators for comfort furniture
- Мотор-редукторы Bonfiglioli, промышленная фурнитура Elesa-Ganter и др. комплектующие
- LINAK – la technologie du vérin électrique au service du mouvement
- LINAK – la technologie du vérin linéaire électrique au service du mouvement
- HIMALAYA GROUP | Pusat Peralatan Industri | Mechanical & Electrical
- Industrial Specialised Applications | isaza | South Africa
- LINAK: tecnologia negli attuatori lineari elettrici
- LINAK: sistemas de tecnología de actuador lineal eléctrico para movimiento
- LINAK Profiles - a modern and state-of-the-art steel company
- LINAK - electric linear actuator technology systems for movement
- LINAK – elektrische lineaire actuatortechnologie om beweging te creëren
- LINAK – Elektrische Linearantriebssysteme, die für Bewegung sorgen
- LINAK - 电动直线推杆运动技术系统
- LINAK - electric linear actuator technology systems for movement
- LINAK - electric linear actuator technology systems for movement
- LINAK - electric linear actuator technology systems for movement
- LINAK - Tecnologia de sistemas de atuadores lineares elétricos para movimento
- LINAK: Hareket için elektrikli lineer aktüatör sistemleri
- HOMELINE: LINAK segment - actuators for comfort furniture
- LINAK warranty
- LINAK – systémy s technologií elektrických lineárních pohonů k zajištění pohybu
- LINAK – Elektrische Linearantriebssysteme, die für Bewegung sorgen
- LINAK - elektrisk lineær aktuatorteknologi til systemer med bevægelse
- LINAK: sistemas de tecnología de actuador lineal eléctrico para movimiento
- LINAK – la technologie du vérin électrique au service du mouvement
- LINAK - electric linear actuator technology systems for movement
- LINAK - 動きを生み出す電動アクチュエータ システム
- LINAK - 움직임을 위한 전동 리니어 액추에이터 테크놀로지 시스템
- LINAK - sistem teknologi penggerak linear elektrik untuk pergerakan
- LINAK – elektrische lineaire actuatortechnologie om beweging te creëren
- LINAK – teknologiske systemer for bevegelse ved bruk av elektriske lineære aktuatorer
- LINAK — systemy ruchu oparte na technologii elektrycznych siłowników liniowych
- LINAK - electric linear actuator technology systems for movement
- LINAK – elektriska linjära ställdonssystem för rörelser
- LINAK – systémy s technológiou elektrických lineárnych aktuátorov pre pohyb
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>