ibiza PLUTON10-LZR 12w LED ‘Spot’ Moving Head User Manual

June 6, 2024
ibiza

ibiza PLUTON10-LZR 12w LED ‘Spot’ Moving Head

ibiza LZR150G Laser Show System FIG 1

BEFORE YOU BEGIN

Contents of the carton:

  •  1 x LED moving head
  •  1x Mains lead
  •  1x User Manual

Unpacking Instructions

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present and have been received in good condition. Notify the freight company immediately and retain packing material for inspection if any parts appear to be damaged from shipping or the carton itself shows signs of mishandling. Keep the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.

Safety Instructions

Please read these instructions carefully, they include important information about the installation, usage and maintenance of this product.

  •  Please keep this User Guide for future reference. If you sell the unit to another user, be sure that he also receives this instruction booklet.
  •  Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture.
  •  This product is intended for indoor use only!
  •  It is essential that the device is earthed. A qualified person must carry out the electric connection.
  •  To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable materials close to the unit while operating.
  •  The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked.
  •  Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse size and type.
  •  Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carrying handles.
  •  Maximum ambient temperature (Ta) is 104° F (40°C). Do not operate the fixture at temperatures higher than this.
  •  In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type of spare parts.
  •  Don’t connect the device to a dimmer pack.
  • Make sure the power cord is never crimped or damaged.
  • Never disconnect the power cord by pulling or tugging on the cord.
  •  Avoid direct eye exposure to the light source while it is on.
    DISCONNECT DEVICE: Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.

Features

  •  11/13 DMX channels
  •  Color wheel : 7 colors + white
  •  7 fixed gobos + spot
  • Green laser with 4 gobos
  • Gobo Shake & Gobo Scroll effects
  • Strobe effect
  •  Manual focus
  • Modes : DMX, sound activated, master-slave or 4 built-in programs
  • 5 dimmer curves (standard, stage, TV, architecture & theater)
  •  Pan/Tilt inversion
  •  Fan cooled

Specifications

  • Power supply…………………………………………………………………………. 100-240Vac 50/60Hz
  • Consumption…………………………………………………………………………………………………  45W
  • Fuse ……………………………………………………………………………………………………………….. 2A
  • Light sources …………………………………………………………………………….1x WHITE 12W LED …………………………………………………………………………………..Green laser 30mW (532nm)
  • Light output……………………………………………. 5120 lux @ 2m; 1189 lux @4m (13° beam)
  • Beam angle…………………………………………………………………………………………………….. 13°
  • Pan/Tilt……………………………………………………………………………………. 540°/230° (16  bits)
  • Dimensions……………………………………………………………………………… 159 x 147 x 265mm
  • Weight………………………………………………………………………………………………………… 3.4kg

Installation

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times the weight of the unit when installing the fixture.
The equipment must be fixed by professionals at a place where is out of the reach of people and where nobody can pass by or under it.

Fuse Replacement

WARNING:

  • Disconnect the power cord before replacing a fuse and always replace with the same type fuse.
  • With a flat head screwdriver wedge the fuse holder out of its housing.
  • Remove the damaged fuse from its holder and replace with exactly the same type of fuse.
  • Insert the fuse holder back in its place and reconnect power.

CONTROL PANEL

To access the main menu press the MENU button. Press the UP or DOWN buttons until you reach function you wish to change. When you reach the function you wish to change, press the ENTER button. When a function is selected, use the UP or DOWN buttons to change the function settings. Once your changes are made, press the ENTER button, and then press and hold the MENU button for at least three seconds to confirm and lock the change into the system memory. To exit without making any adjustments, press the MENU BUTTON. The display will lock after 30 seconds.

Press the MENU button for 3 seconds to unlock.

FUNCTION MENU

ADDR 001 – 512, DMX Address setting
CHND 11 ch

13 ch, select the channel mode

SHND| SHOW 0 – SHOW 4, Select the show mode


SLND

| Mast SL 1

SL 2 ( MASTER, SLAVE OPTION)




dINd

| Dimmer Mode Stda(Standard) StGE(Stage) tv(TV)

ArAL(Architectural) tHAL(Theatrical)

AUTO| OFF (sound controlled mode) ON (Auto Mode)
SENS| 000 – 100  Sound sensitivity control  (0 close, 100 The most sensitive)
PINT| Yes – No  (PAN Reverse)
TINT| Yes – No  (TIL Reverse)
LED| On – Off (Background LIGHT ON/OFF)
DISP| Disp

Dsip (Reverse Display)

TEST| Test
RSET| Reset

Settings

DMX Address Setting

  1.  Press the MENU, UP or DOWN button until “ADDR” is displayed, press ENTER.
  2. The current address will now be displayed and flashing. Press the UP or DOWN buttons to find your desired address.
  3. Press ENTER to confirm.

DMX channel mode

  1.  Press the MENU button until “CHND” is displayed, press ENTER. Either “11CH”, “13CH” will be displayed
  2. Press the UP or DOWN buttons to find your desired DMX channel mode and press ENTER to confirm and exit.

Show modes 0-4 (Factory programs).
Show mode can run with or without sound active mode active.

  1. Press the MENU button until “SHND” is displayed, press ENTER.
  2. “Sh X” will now be displayed, “X” representing a number between 0-4. Programs 1-4 are factory programs, while “Sh 0” is random mode. Press the UP or DOWN buttons to find your desired show.
  3.  When you have found your desired show press ENTER.

dINd
This option is for setting dimmer curves. Press MENU to select dINd, Then press Enter to start setting, UP or DOWN to select the dimmer curves, there are five dimmer curves Stda, StGE, tv, ArAL and tHAL for your choice, then press Enter again to confirm your selection.

Stda Standard

  • StGE Stage
  • Tv TV
  • ArAL Architectural
  • tHAL Theatrical

SLnd
This option is for setting the unit’s Master-slave mode. Press MENU to select SLnd Then press Enter to start setting. You will find MAST, SL1, SL2. Press UP or DOWN to choose Master or slave, then press Enter again to confirm your selection.

  • MAST: Choose the device as master
  • SL1: Choose the device as slave
  • SL2: Assistant Mode

AUTO program (sound active mode)

  1. Press the MENU button until “AUTO” is displayed, press ENTER.
  2. The Display will show either “ON” or “OFF”. Press the UP or DOWN buttons to select “ON” or “OFF”.
  3. If you choose “OFF”, the unit will be in sound controlled mode and you can set the sound sensitivity.

Sound sensitivity

  1. Press the MENU button until “SENS” is displayed, press ENTER.
  2.  A number between 0-100 will be displayed. Press the UP or DOWN buttons to adjust the sound sensitivity. 0 being the least sensitive and 100 being the most sensitive. When you have found your desired setting press ENTER to confirm.

Pan Inversion

  1. Press the MENU button until “ PINT ” is displayed, press ENTER. Either “YES” or “NO” will be displayed
  2. To activate the Pan inversion press the UP or DOWN buttons until YES is displayed, press ENTER to confirm. To deactivate Tilt inversion, select NO and press

Tilt Inversion

  1. Press the MENU button until “ TILT ” is displayed, press ENTER. Either “YES” or “NO” will be displayed
  2. To activate the Tilt inversion press the UP or DOWN buttons until YES is displayed, press ENTER to To deactivate Tilt inversion, select NO and press Enter.

Display back light

  1. Press the MENU button until “ LED ” is displayed, press enter
  2. The display will show either “ ON” or “OFF ”. Press the UP or DOWN buttons to select “ ON ” to keep the LED display on at all times, or “ OFF ” to switch to have the LED display switch off after 10  seconds
  3. Press ENTER and then press and hold the MENU button for at least three seconds to confirm

Display Reverse 180°

  1. Press the either the MENU button until “ DISP ” is displayed, press ENTER
  2. Press the UP button to select “ DSIP ” to reverse the display, or “ DISP ” to change the display back
  3. Press ENTER to CONFIRM

Self test program

  1. Press the MENU button until “ TEST ” is displayed, press ENTER
  2. The fixture will now run a self test. Press MENU to exit.

Reset

  1.  Press the MENU button until “Reset” is displayed. Press the ENTER button and the unit will reset itself.

DMX CHANNELS

Mode 1

(11)

| Channel| | Mode 2

(13)

| Channel
---|---|---|---|---
1| Pan| | 1| Pan
2| Tilt| | 2| Pan Fine
3| Color| | 3| Tilt
4| Gobo| | 4| Tilt Fine
5| Laser Motor (4 gobos)| | 5| Color
6| Strobe| | 6| Gobo
7| Dimmer| | 7| Laser Motor (4 gobos)
8| Laser Strobe| | 8| Strobe
9| Pan/Tilt speed| | 9| Dimmer
10| Function| | 10| Laser Strobe
11| Dimmer Curves| | 11| Pan/Tilt speed
| | | 12| Function
| | | 13| Dimmer Curves


Function

| ****

Value

| ****

Percent / Setting

| Mode 11CH| Mode 13CH
---|---|---|---|---
Pan| 000-255| 0~100%| 1| 1
Pan Fine| 000-255| 0~100%| | 2
Tilt| 000-255| 0~100%| 2| 3
Tilt Fine| 000-255| 0~100%| | 4








Color

| 000-008

009-017

018-026

027-035

036-044

045-053

054-062

063-071

072-080

081-089

090-098

099-107

| Color 1

Color 1 +Color 2

Color 2

Color 2 +Color 3

Color 3

Color 3 +Color 4

Color 4

Color 4 +Color 5

Color 5

Color 5 +Color 6

Color 6

Color 5 +Color 7

| ****







3

| ****







5

| 108-116

117-125

126-127

128-189

190-193

194-255

| Color 7

Color 7 +Color 8

Color 8

Color Scroll from fast to slow Stop

Color Scroll from slow to fast

| |
---|---|---|---|---

Gobo

| 000-007

008-015

016-023

024-031

032-039

040-047

048-055

056-063

064-071

072-079

080-087

088-095

096-103

104-111

112-119

120-127

128-189

190-193

194-255

| Gobo 1

Gobo 2

Gobo 3

Gobo 4

Gobo 5

Gobo 6

Gobo 7

Gobo 8

Gobo 1 shake

Gobo 2 shake

Gobo 3 shake

Gobo 4 shake

Gobo 5 shake

Gobo 6 shake

Gobo 7 shake

Gobo 8 shake

Gobo Scroll, Fast to Slow Stop

Gobo Scroll , Slow to Fast

|

4

|

6

Laser Motor

| 000-007

008-131

132-255

| Stop

Forward rotate Reverse rotate

|

5

|

7

Strobe

| 000-007

008-015

016-131

132-139

140-181

182-189

190-231

232-239

240-247

248-255

| Close Open

Strobe Slow->Fast Open

Fast Close Slow Open Open

Fast Open Slow Close Open

Random Strobe

Open

|

6

|

8

Dimmer| 000-255| 0~100%| 7| 9

Laser Strobe

| 000-007

008-015

| Close Open|

8

|

10

| 016-131

132-240

240-247

248-255

| Strobe Slow->Fast Open

Random Strobe

Open

| |
---|---|---|---|---
Pan/Tilt Speed| 000-255| Fast -> Slow| 9| 11

Function

| 000-069

070-079

080-089

090-099

100-109

110-119

120-199

200-209

210-249

250-255

| Null

Blackout while Pan/Tilt Move Null

Blackout when Color wheel move Null

Blackout when Gobo Wheel move Null

Reset All Null

Sound Active

|

10

|

12

Dimmer Curves

| 000-050

051-100

101-150

151-200

201-250

| Standard Stage

TV

Architectural Theatre

|

11

|

13

Cleaning

Due to fog residue, smoke, and dust cleaning the internal and external lenses should be carried out periodically to optimize light output.

  1.  Use normal glass cleaner and a soft cloth to wipe down the out-side casing.
  2. Clean the external optics with glass cleaner and a soft cloth every 20 days.
  3. Always be sure to dry all parts completely before plugging the unit back in.

IMPORTANT NOTE: Electric products must not be put into household waste. Please bring them to a recycling centre. Ask your local authorities or your dealer about the way to proceed.