Product Specifications

  • Model: LA14IO

  • ATEX-approved O-ring color: Brown

  • IP Degree: IP66

  • Operating Voltage Options: 12 V DC, 24 V DC, 12 V DC Fast, 24 V
    DC Fast, Other

  • Feedback options: Potentiometer, Single Hall, Hall potentiometer, PWM

  • Endstop Options: No endstop reached signal, Endstop reached signal

  • Bus Options: LIN bus, CAN bus (J1939), CANopen

Product Usage Instructions
Replacing an ATEX Cable

  1. Loosen the screw to disassemble the cable relief.
  2. Remove the cable relief by pulling it in the same direction as the screw.
  3. Remove the plugged cable.
  4. Insert the cable (0147006-xxxx) with an ATEX-approved Brown O-ring.

Correct Mounting of Cable
The brown O-ring should not be visible after mounting to ensure a tight application.

Incorrect Mounting of Cable
If the brown O-ring is visible after mounting, and the application is NOT tight, it is incorrectly mounted.

Frequently Asked Questions (FAQ)

Q: Who should repair LINAK actuator systems?
A: Only authorized LINAK service centers should repair LINAK actuator systems. Systems under warranty must be sent to an authorized service center to avoid malfunction risks.

Replacing an ATEX cable

  • Loosen the screw to disassemble the cable relief.
  • Remove the cable relief by pulling it in the same direction as the screw.
  • Remove the plugged cable.
  • Insert the cable (0147006-xxxx) with an ATEX-approved O-ring.
  • The colour of the O-ring must be Brown.

LINAK-LA14IO-Tough-Electric-IC-Actuator- \(2\)

Correct mounting of cable
The brown O-ring is not visible.

Incorrect mounting of cable

  • The brown O-ring is visible and the application is NOT tight.
  • Place the cable relief on the actuator housing, then
  • place and tighten the screw.
  • Fasten it to 3 Nm ± 0.5 Nm

LINAK-LA14IO-Tough-Electric-IC-Actuator- \(3\)

Key to Symbols

The following symbols are used on the LA14IO labels:

LINAK-LA14IO-Tough-Electric-IC-Actuator- \(1\)

Ordering Example

14 020 040| 00 00 0 A 0 6 = 1| 1| 0| 0| 245| 0 C S 0 0 0
---|---|---|---|---|---|---


Type

| ****

14

| ****

=

| ****

LA14IO

|  |  |
Spindle pitch| 020| =| 2 mm|  |  |
 | 040| =| 4 mm|  |  |
Stroke length| XXX| =| mm|  |  |
Safety nut| 00| =| None|  |  |
Feedback| 00

0P

0K

0A

0F

| =

=

=

=

=

| None Potentiometer Single Hall

Hall potentiometer PWM

|  |  |
Platform| 0| =| None| B| =| I/O Basic
 | 3| =| IC| C| =| I/O Customised
 | 6| =| LIN bus| F| =| I/O Full
 | 7| =| CAN bus (J1939)| X| =| Special
 | 8| =| CANopen|  |  |
Motor type| A| =| 12 V DC|  |  |
 | B| =| 24 V DC|  |  |
 | C| =| 12 V DC Fast|  |  |
 | D| =| 24 V DC Fast|  |  |
 | X| =| Other|  |  |
Endstop| 0| =| Power switch|  |  |
 | 1| =| Signal switch|  |  |
 | 2| =| Zero Point|  |  |
IP degree| 6

T

| =

=

| IP66

ATEX

| 9| =| Harsh environment

+ IP66/IP69K

Colour| =| =| Dark Olive Grey (NCS S7000-N)|  |  |
Back fixture| 1| =| | A| =| 0° with POM
 | 2| =| 90°| B| =| 90° with POM
Piston rod eye| 1| =| Ø10.2 Zinc-coated steel| A| =| Ø10 2 AISI 304
 | 2| =| Ø12 3 Zinc-coated steel| C| =| Ø8 1 AISI 304 + bush
 | 3| =| Ø12 3 AISI 304| D| =| Ø10 2 AISI 304 + bush
 | 4| =| Ø12 3 AISI 303| E| =| Ø10 2 AISI 303 + bush
 | 5| =| Ø8 1 Zinc-coated steel + bush| F| =| Female adapter M8
 | 6| =| Ø10 2 Zinc-coated steel + bush| K| =| Ball eye Ø10H7
 |  |  |  | L| =| Ball eye Ø12H7
 |  |  |  | M| =| Male adapter M12 AISI 304
 |  |  |  | X| =| Special
Position| 0| =| No endstop reached signal|  |  |
 | 1| =| Endstop reached signal|  |  |
14 020| 040| 00 00 0 A 0 6 = 1 1 0 0 245 0 C S 0 0 0
---|---|---


Brake

| ****

0

| ****

=

| ****

None

BID| 245

XXX

| =

=

| mm (min length) mm
Fire category| 0| =| None
Plug type| 0| =| None
 | C| =| Flying leads
 | I| =| Deutsch (DT4) Moulded
 | J| =| Deutsch (DT4)
 | K| =| AMP Superseal
 | L| =| AMP Superseal Moulded
 | X| =| Special
Cable| 0| =| None
 | S| =| Straight 0.75 m (8-core or 2-core when no feedback is needed)
 | T| =| Straight 15 m (8-core or 2-core when no feedback is needed)
 | R| =| Straight 5 m (8-core or 2-core when no feedback is needed)
 | V| =| Straight 10 m (8-core or 2-core when no feedback is needed)
 | Y| =| Straight 15 m (11-core)
 | Z| =| Straight 5 m (11-core)
 | X| =| Special
Safety factor| 0| =| 2.0
Feedback level|  |  |
None

0          = None

| IC Basi

8

| c

=

| ****

None

| IC Advanced and I/O IC Parallel (Not I/O

0          =   None Z          = Parallel

A| = 0-10 V|  |  |  | G| =| 0-10 V
B| =   05-45 V|  |  |  | H| =| 05-4 5 V
C| = 4-20 mA|  |  |  | J| =| 4-20 mA
D| = PWM 10-90%| K| =| PWM 10-90%
E| = PWM 20-80%|  |  | (Only IC Advanced)
F| = Special| L| =| PWM 20-80%
CAN / CANopen / LIN bus

0          = None

| ****

X

| ****

=

| (Only IC Advanced)

Special

Parallel mode| 0| =| Non-Critical Parallel (Not for I/O)
 | 2-8| =| Critical Parallel (Count of actuators)

Maintenance

  • The actuator must be cleaned at regular intervals to remove dust and dirt, and it must be inspected for mechanical damages or wear
  • Inspect attachment points, wires, piston rod, cabinet, and plugAlso check whether the actuator functions correctly
  • To ensure that the pre-greased inner tube remains lubricated, the actuator must only be washed down when the piston rod is fully retracted
  • The actuator is a closed unit and therefore requires no internal maintenance
  • In order to maintain a proper performance of the spherical eyes and to increase the resistance against environmental wear, we strongly recommend that the spherical eyes (ball bearings) mounted on actuators from LINAK® are greased with anticorrosive grease or similar

Repair
Only an authorised LINAK service centre should repair LINAK actuator systems Systems to be repaired under warranty must be sent to an authorised LINAK service centre
In order to avoid the risk of malfunction, all actuator repairs must only be carried out by an authorized LINAK Service shop or repairer, as special tools and parts must be used
If a system is opened by unauthorised personel, there is a risk that it may malfunction at a later date

Main Groups of Disposal
LINAK’s products may be disposed of, possibly by dividing them into different waste groups for recycling or combustion
We recommend that our product is disassembled as much as possible at the disposal and recycled when possible

Product| Metal scrap| Cable scrap| Electronic scrap| Plastic recycling or combustion
---|---|---|---|---
LA14IO| X| X| X| X

Warranty

There is an 18 month warranty on TECHLINE™ products against manufacturing faults calculated from the production date of the individual products (see label)  The LINAK® warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tampered with  Furthermore, the actuator must not be exposed to violent treatment  In the event of this, the warranty will be ineffective/invalid For further details, please see standard terms of sale and delivery for LINAK A/S

Note:

  • Only an authorized LINAK® service centre should repair LINAK actuator systems  Systems to be repaired under warranty must be sent to an authorized LINAK service center
  • In order to avoid the risk of malfunction, all actuator repairs must only be carried out by an authorized LINAK Service shop or repairer, as special tools and parts must be used
  • If a system is opened by unauthorized personnel there is a risk that it may malfunction at a later date
  • The actuator is not to be opened by unauthorised personnel  In case the actuator is opened, the warranty will be invalid

FCC Statement – LA14IO with Bluetooth®

Note:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules  These limits are designed to provide reasonable protection against harmful interference in a residential installation  This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications
However, there is no guarantee that interference will not occur in a particular installation? If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
  • Consult the dealer or an experienced radio/TV technician for help  Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment

This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation

This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s) Operation is subject to the following two conditions

  1.  This device may not cause interference
  2. This device must accept any interference, including interference that may cause undesired operation of the device

Contacts

USA
LINAK U.S. Inc.
Americas Headquarters
Phone: +1 502 253 5595
Fax: +1 502 253 5596
Web: www.linak-us.com
www.linak-latinamerica.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LINAK User Manuals

Related Manuals