ELATION PROFESSIONAL KL FRESNEL 6 FC RGBMA LED Fresnel Light User Manual
- June 12, 2024
- ELATION PROFESSIONAL
Table of Contents
- ELATION PROFESSIONAL KL FRESNEL 6 FC RGBMA LED Fresnel Light
- Product Information
- Product Usage Instructions
- GENER AL INFORMATION
- BOX CONTENTS
- LIMITED WARRANTY
- SAFETY GUIDELINES
- MAINTENANCE GUIDELINES
- OVERVIEW
- INSTALLATION INSTRUCTIONS
- ACCESSORY INSTALLATION
- SYSTEM MENU
- DMX TRAITS
- COLOR TEMPERATURE TABLE
- VIRTUAL COLORS
- SPECIFICATIONS
- DIMENSIONAL DR AWINGS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ELATION PROFESSIONAL KL FRESNEL 6 FC RGBMA LED Fresnel Light
Product Information
The KL FRESNEL 6 FC is a professional lighting fixture manufactured by Elation Professional. It is designed for use by professionals and is not suitable for private use. The fixture comes with a power cable, gel filter, and barndoor included in the box.
Customer Support
If you have any product-related service or support needs, you can contact ELATION Service. For questions, comments, or suggestions, you can also visit the ELATION forums.
ELATION SERVICE USA:
- Monday – Friday: 8:00am to 4:30pm PST
- Phone : 323-582-3322
- Fax : 323-832-9142
- Email : support@elationlighting.com
ELATION SERVICE EUROPE:
- Monday – Friday : 08:30 to 17:00 CET
- Phone: +31 45 546 85 63
- Fax: +31 45 546 85 96
- Email: support@elationlighting.eu
Replacement Parts
If you need replacement parts for the fixture, you can visit parts.elationlighting.com.
Important Safety Information
It is important to read and understand the instructions in the manual before
operating the device. The manual contains important safety and use
information. Please note that there are no user-serviceable parts inside the
unit, and any attempts to repair the unit yourself will void the
manufacturer’s warranty. Damages resulting from modifications to the fixture
or disregard of safety instructions in the manual are not covered by the
warranty.
To maximize the operational lifespan of the fixture, it is strongly
recommended to power it down completely when not in use. This reduces wear on
the fixture caused by sustained or extended operational periods.
Product Usage Instructions
Before using the KL FRESNEL 6 FC, please ensure that you have read and understood the safety guidelines provided in the user manual.
Installation
Follow the installation instructions provided in the manual to properly set up the fixture. Ensure that the power cable is securely connected.
Accessory Installation
If you want to install additional accessories such as a gel filter or barndoor, refer to the accessory installation section of the manual for step- by-step instructions.
Remote Device Management (RDM)
The fixture supports Remote Device Management (RDM). Refer to the RDM section of the manual for information on how to use this feature.
System Menu | Software Update
The system menu allows you to perform software updates on the fixture. Follow the instructions in the manual to update the software when necessary.
Encoder Knobs
The fixture is equipped with encoder knobs. Refer to the manual for information on how to use and adjust these knobs.
DMX Traits
The DMX channel mode of the fixture can be adjusted. Refer to the DMX traits section of the manual for details on different channel modes and how to set them.
Color Temperature Table
The manual provides a color temperature table for reference. Use this table to select the desired color temperature for your lighting needs.
Virtual Colors
The fixture offers virtual colors. Refer to the manual for information on how to access and use these virtual colors.
Specifications
For detailed specifications of the KL FRESNEL 6 FC, refer to the specifications section of the manual.
Dimensional Drawings
The manual includes dimensional drawings of the fixture. Consult these drawings for information on the physical dimensions of the fixture.
©2022 ELATION PROFESSIONAL all rights reserved. Information, specifications,
diagrams, images, and instructions herein are subject to change without
notice. ELATION PROFESSIONAL logo and identifying product names and numbers
herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed
includes all forms and matters of copyrightable materials and information now
allowed by statutory or judicial law or hereinafter granted. Product names
used in this document may be trademarks or registered trademarks of their
respective companies and are hereby acknowledged. All non-ELATION brands and
product names are trademarks or registered trademarks of their respective
companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages,
injuries to any persons, and direct or indirect economic loss associated with
the use or reliance of any information contained within this document, and/or
as a result of the improper, unsafe, insufficient and negligent assembly,
installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 |
323-832-9142 fax |
www.elationlighting.com |
info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The
Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax |
www.elationlighting.eu |
info@elationlighting.eu
Elation Professional Mexico
AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000
+52 728-282-7070
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of this document may be available online. Please scan the QR Code with your mobile device or visit www.elationlighting.eu for the latest revision/update of this manual, before installation and/or programming.
Date| Document Version| Software Version| DMX Channel
Mode| Notes
---|---|---|---|---
04/04/22| 1.0| 1.0.1A| 1 / 6 / 11 / 18 / 9 / 14 ch.| Initial Release
09/21/22| 1.1| N/C| N/C| Update Dim. Drawings.
11/09/22| 1.2| N/C| N/C| Updated specifications
04/18/23| 1.3| 1.0.4A| N/C| Update Software/RDM
functionality
| | | |
| | | |
GENER AL INFORMATION
INTRODUCTION
Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this device. These instructions contain important safety and use information. This device is intended for use by professionals only, and is not suitable for private use.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton is damaged, carefully inspect the device for damage, and be sure all accessories necessary to install and operate the device have arrived intact. In the event that damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this device to your dealer without first contacting customer support. Please do not discard the shipping carton in the trash. Please recycle whenever possible.
BOX CONTENTS
- Power Cable (x1)
- Gel Filter (x1)
- Barndoor (x1)
- IP RATING
An IP rated lighting fixture has been designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as dust and/or water. The Ingress Protection (IP) rating system is commonly expressed as “IP” followed by two numbers (i.e. IP20), where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture and the second digit (Water Protection) indicates the extent of protection against water entering the fixture. An IP20 rated lighting fixture, such as this one, has been designed and tested to protect against the ingress of solids as small as the size of an adult finger (approximately 12.5mm), but is NOT protected against liquid intrusion of any kind.
CUSTOMER SUPPORT – Contact ELATION Service for any product related
service and support needs. Also visit forums.elationlighting.com with
questions, comments, or suggestions.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax
323-832-9142 |
support@elationlighting.com ELATION
SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
+31 45 546 85 63 | Fax +31 45 546 85 96 |
support@elationlighting.eu REPLACEMENT
PARTS please visit
parts.elationlighting.com
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES
RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY
INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY
AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
It is strongly recommended to power the fixture down completely when not in
use. Doing so will reduce wear on the fixture due to sustained or extended
operational periods, thereby maximizing its operational lifespan.
LIMITED WARRANTY
- A. Elation Professional hereby warrants, to the original purchaser, Elation Professional prod-ucts to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
- B. For warranty service, send the product only to the Elation Professional factory. All ship-ping charges must be pre-paid. If the requested repairs or service (including parts replace-ment) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof.
- C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional concludes, after inspec-tion, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by Elation Professional; if the product is damaged because not prop-erly maintained as set forth in the product instructions, guidelines and/or user manual.
- D. This is not a service contract, and this warranty does not include any maintenance, clean-ing or periodic check-up. During the periods as specified above, Elation Professional will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect.
- E. Elation Professional reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
- F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including war-ranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
- G. This warranty is the only written warranty applicable to Elation Professional products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
WARRANTY RETURNS
All returned service items whether under warranty or not, must be freight pre- paid and accompanied by a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem, as well as the R.A. number, must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without an R.A. number clearly marked on the outside of the package will be refused and returned at customer’s expense. You may obtain an R.A. number by contacting customer support.
SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufacturer’s warranty and increase the risk of damage and/or personal injury.
- PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED.
- THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS DEVICE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
- DO NOT PLUG THIS UNIT INTO A DIMMER PACK!
- NEVER OPERATE THIS UNIT WITH THE CASING REMOVED!
- DISCONNECT POWER BEFORE PERFORMING MAINTENANCE!
- NEVER TOUCH DURING OPERATION, AS FIXTURE SURFACES MAY BE HOT!KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
- NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
- RETINA INJURY RISK – MAY INDUCE BLINDNESS!
- SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
- FOR USE IN INDOOR OR DRY LOCATIONS ONLY!
- DO NOT EXPOSE TO RAIN AND/OR MOISTURE!
- THIS FIXTURE IS IP20 RATED, AND HAS BEEN DESIGNED AND TESTED TO PROTECT AGAINST THE INGRESS OF SOLIDS AS SMALL AS THE SIZE OF AN ADULT FINGER (APPROXIMATELY 12.5MM), BUT IS NOT PROTECTED AGAINST LIQUID INTRUSION OF ANY KIND.
- MINIMUM DISTANCE TO OBJECTS/SURFACES IS 1.0 FOOT (0.3 METER) MINIMUM DISTANCE TO FLAMMABLE MATERIALS IS 1.6 FEET (0.5 METER) MAXIMUM AMBIENT OPERATING TEMPERATURE IS 113° F (45° C)
SAFETY GUIDELINES
- DO NOT TOUCH the fixture housing during operation.
- DO NOT shake fixture, and avoid brute force when installing and/or operating fixture.
- DO NOT operate fixture if the power cord is frayed, crimped, damaged and/or if any of the power cord connectors are damaged or do not fit into the fixture securely with ease.
- NEVER force a power cord connector into the fixture. If the power cord or any of its connectors are damaged, replace it immediately with a new one of the same power rating.
- DO NOT block any air ventilation slots. All fan and air inlets must remain clean and never blocked. Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling.
- TURN OFF the power and allow approximately 15 minutes for the fixture to cool down before servicing.
- ALWAYS disconnect fixture from power before performing any service and/or cleaning procedure.
- ONLY handle power cord by the plug end. Never pull plug out by tugging the wire portion of the cord.
- During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the LED and will decrease gradually over time.
- Consistent operational breaks will ensure fixture will function properly for many years.
- ONLY use the original packaging and materials to transport the fixture for service.
MAINTENANCE GUIDELINES
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
CLEANING
Frequent cleaning is recommended to ensure proper function, optimized light
output, and an extended life. The frequency of cleaning depends on the
environment in which the fixture operates: damp, smoky, or particularly dirty
environments can cause greater accumulation of dirt on the fixture’s optics.
Clean periodically with a soft cloth to avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to ensure proper function and extended life. There are no user serviceable parts inside this fixture. Please refer all service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from an authorized Elation dealer.
Please refer to the following points during routine inspections:
- A detailed electrical check by an approved electrical engineer every three months, to make sure the circuit contacts are in good condition and prevent overheating.
- Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out during normal operation, resulting in damage or injury as larger parts could fall.
- Check for any deformations on the housing, color lenses, rigging hardware, and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s).
- Electric power supply cables must not show any damage, material fatigue, or sediments.
NEVER remove the ground prong from the power cable.
OVERVIEW
INSTALLATION INSTRUCTIONS
- FLAMMABLE MATERIAL WARNING
- Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics.
- ELECTRICAL CONNECTIONS
- A qualified electrician should be used for all electrical connections and/or installations.
- MINIMUM DISTANCE TO OBJECTS/SURFACES IS 1 FOOT (0.3 METERS) MINIMUM DISTANCE TO FLAMMABLE MATERIALS IS 1.6 FEET (0.5 METERS) MAXIMUM AMBIENT OPERATING TEMPERATURE IS 113° F (45° C)
- INDOOR USE ONLY! THIS DEVICE IS NOT INTENDED FOR OUTDOOR USAGE, OR EXPOSURE TO RAIN OR MOISTURE! USE OF THIS DEVICE OUTDOORS VOIDS YOUR MANUFACTURER’S WARRANTY!
- DO NOT PERFORM THE INSTALLATION YOURSELF IF YOU ARE NOT QUALIFIED TO DO SO!
- Fixture MUST be installed following all local, national, and country commercial electrical and construction codes and regulations.
- Before rigging/mounting a single fixture or multiple fixtures to any metal truss/structure or placing the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture(s), clamps, cables, and accessories.
- Maximum fixture ambient operating temperature is 113°F (45°C). Do not operate this fixture when ambient temperature exceeds this rating.
- Overhead rigging requires extensive experience, including calculating working load limits, knowledge of installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.
- Fixture(s) should be installed in areas outside walking paths, seating areas, or areas where unauthorized personnel might reach the fixture by hand.
- NEVER stand directly below the fixture(s) when rigging, removing, or servicing.
- Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable.
- Allow approximately 15 minutes for the fixture to cool down before serving.
RIGGING
Overhead rigging requires extensive experience, including calculating working
load limits, knowledge of installation material being used, and periodic
safety inspection of all installation material and the fixture, among other
things. If you lack these qualifications, do not attempt the installation
yourself. Improper installation can result in bodily injury.
CLAMP INSTALLATION
The included yoke bracket features a built-in attachment point for a mounting
clamp. The fixture itself also features a safety cable loop, located near the
top of the rear panel, as shown in the illustration below. Please note that
the designated safety cable loop is the only safe location to attach a safety
cable! Never attach a safety cable to the mounting clamp bracket!
ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THAT THE FIXTURE WILL NOT FALL IF THE CLAMP FAILS.
STAND MOUNTING
This unit can also be installed atop a tripod stand. Simply insert the
threaded bolt on the top of the tripod stand through the hole in the top of
the mounting yoke. Tighten the nut onto the threaded bolt to secure the
mounted device in place.
CAUTION!
- MAKE SURE THAT THE TRIPOD LEGS AND ALL TELESCOPING ELEMENTS OF THE TRIPOD STAND ARE LOCKED IN PLACE BEFORE INSTALLING THE DEVICE ATOP THE STAND!
- POSITION THE TRIPOD STAND AND MOUNTED DEVICE ONLY ON FLAT, STABLE SURFACES! DEPLOY TRIPOD LEGS FULLY IN ORDER TO MAXIMIZE STABILITY!
POTENTIAL INTERNAL FIXTURE DAMAGE FROM EXTERNAL SOURCES OF LIGHT BEAMS
- External sources of light beams from direct sunlight, moving head lighting fixtures, and lasers which are focused directly towards the exterior housing and/or penetrate the front lens opening of Elation lighting fixtures can cause severe internal damage, including burning of optics, dichroic color filters, glass and metal gobos, prisms, animation wheels, frost filters, irises, shutters, motors, belts, wiring, discharge lamps, and LEDs.
- This issue is not unique to Elation lighting fixtures, but rather it is a common issue with lighting fixtures from all manufacturers. Although there is no true way to completely prevent this issue from occurring, the guidelines below can reduce the risk of any potential damage if followed. Contact Elation Service for more details.
- DO NOT EXPOSE THE FIXTURE AND/OR FRONT LENS OPENING TO LIGHT BEAMS FROM DIRECT SUNLIGHT, OTHER LIGHTING OR MOVING HEAD FIXTURES, AND LASERS DURING UNPACKING, INSTALLATION, USE, AND EXTENDED IDLE TIMES OUTDOORS. DO NOT FOCUS A LIGHT BEAM FROM ONE LIGHTING FIXTURE DIRECTLY TOWARDS ANOTHER.
ACCESSORY INSTALLATION
GEL FILTER
This unit includes a gel filter accessory that can be installed or removed. To install, find the lens frame latch positioned at the top of the lens, press the locking mechanism to unlock the latch, and swing the latch upwards (below left). Then simply slide the gel frame into the lens frame (below right), making sure to use the frame slot that is closest to the lens. Flip the lens frame latch back down to secure the gel frame in place.
ACCESSORY INSTALATION
This unit includes a barndoor accessory that can be installed or removed. To
install, first find the lens frame latch located at the top of the lens frame.
Press the locking mechanism to unlock the latch, then swing the latch upwards
(below left). Slide the barndoor into an open lens frame slot (below middle).
Flip the lens frame latch back down to secure the barndoor in place, then open
the barndoor by pulling outward on the panels (below right).
REMOTE DEVICE MANAGEMENT (RDM)
NOTE : In order for RDM to work properly, RDM enabled equipment must be used throughout the entire system, including DMX data splitters and wireless systems.
- Remote Device Management (RDM) is a protocol that sits on top of the DMX512 data standard for lighting, allowing the DMX systems of the fixtures to be modified and monitored remotely. This protocol is ideal for instances in which a unit is installed in a location that is not easily accessible.
- With RDM, the DMX512 system becomes bi-directional, allowing a compatible RDM enabled controller to send out a signal to devices on the wire, as well as allowing the fixture to respond (known as a GET command). The controller can then use its SET command to modify settings that would typically have to be changed or viewed directly via the unit’s display screen, including the DMX Address, DMX Channel Mode, and Temperature Sensors.
- Please be aware that not all RDM devices support all RDM features, and therefore it is important to check beforehand to ensure that the equipment that you are considering includes all of the features that you require.
The following parameters are accessible in RDM on this device:
Sensor Definition
Sensor Value
Device Model Description
Manufacturer Label
Device Label
DMX Personality
DMX Personality Description
Device Hours
Display Invert
Factory Default
SYSTEM MENU
ENCODER MODE
| Disabled|
---|---|---
Dimmer|
Int CCT Grn|
Int Color Sat|
Manual Control|
DMX SETTINGS
| DMX Address| 001 – 512|
DMX Mode
| 1ch Dimmer|
6ch Dimmer Color|
11ch Standard|
18ch Extended|
9ch CMY|
14ch CMY Extended|
No DMX
Status
| Hold Last| Defines reaction to loss or
interruption
of DMX signal
Fade to Black
Standalone
STANDALONE
| Dimmer| 0% – 100%|
CCT| 2400K – 8500K| Default =
6000K
Green Shift| -100% – 100%| Default = 0%
Virtual Color
|
Color01 – Color53
| Built in color program, see Virtual Colors section of this
manual
PERSONALITY
| Primary| On / Off|
Secondary| On / Off|
Dim Mode| Standard , Stage, TV, Architectural, Theatre,
Stage 2
|
Dim Speed| 0.0s – 10s| Default = 0.1s
Dim Curves| Linear , Square, Square Inverse, S-Curve|
LED Refresh Rate| 900-1500Hz, 1200Hz, 2500Hz, 4000Hz,
5000Hz, 6000Hz, 10KHz, 15KHz, 20KHz,
25KHz
|
LED Power
Limit
| 50%, 60%, 70%, 80%, 90%, 100%|
Fan Mode| Auto , Silent, High|
Display
|
Screen Delay
|
10s – 5min
| Screen returns to home page after a period of inactivity; default =
1min
Screen Lock| Off, 10s – 5min|
Rotate Display
| Yes|
No|
Auto
| Screen automatically rotates to keep display oriented
upright
PERSONALITY
|
Service
|
Passcode = 050
|
Calibration
| Red 50-255|
---|---|---|---|---|---
Green 50-255|
Blue 50-255|
…|
Update
Software
| Yes / No|
Factory
Restore
| Yes / No|
Edit RDM UID| xxxxxx|
INFORMATION
| Life Time| xxxxxx h| Total run hours. Not
resettable
Last Run Time| xxxxxx h| Run hours since last
reset
Time Reset| Passcode = 038| Reset run
hours
Temperature
| Current| Current temp
reading
Max Resettable| Max temp since last
reset
Reset| Passcode = 038| Reset max
temp
DMX Values
| R: xxx|
G: xxx|
B: xxx|
…|
Product IDs| RDM UID| xxxxxx|
Error Logs| Fixture Errors (display one by one)|
Reset Error
Log
| No / Yes| Passcode =
050
|
Software
Version
| Vx.x.x|
The fixture includes an easy to navigate system menu. The control panel display located on the side of the fixture (illustrated below) provides access to the main system menu where all necessary system adjustments are made to the fixture.
- During normal operation, pressing the MODE button once will access the fixture’s main menu.
- Once in the main menu you can navigate through the different functions and access the sub-menus with the DOWN and UP buttons.
- Once you reach a field that requires adjusting, press the ENTER button to activate that field and use the DOWN and UP buttons to adjust the field.
- Pressing the ENTER button once more will confirm the setting.
- Exit the main menu at any time without making any adjustments by pressing the MODE button.
SCREEN LOCK
The screen will lock after a certain period of inactivity. The length of this
time period is configurable in the System Menu, under Personality > Display >
Display Screen Lock. To unlock the screen, press and hold the MODE button for
3 seconds.
WHITE BALANCE
The white balance menu can be accessed by pressing and holding the MODE, DOWN,
and UP buttons simultaneously for 3 seconds. Please note that in this mode,
the Color menu will be disabled, and the ColorTemp menu adjusts the color
temperature white balance.
CONTROL KNOB
This device features an encoder knob located to the right of the display
screen, which is labeled “CTRL.” This encoder knob can be used to manually
adjust dimming, CCT green shift, color saturation, or manual control. Twisting
the knob will scroll through modes and sub-modes, or adjust the value of the
select sub-mode, while pressing the button confirms the selection. Please see
the Encoder Knobs section of this manual for detailed information.
- A USB FLASH DRIVE CAN BE USED TO UPDATE THE FIXTURE TO THE LATEST SOFTWARE. Using a USB Flash Drive loaded with the latest software, insert it into the USB Service Port, then navigate to PERSONALITY/SERVICE, enter the passcode (050), and select UPDATE SOFTWARE. A copy of the latest software can be obtained by contacting Elation Support.
- AN ELATION C-LOADER II CAN ALSO BE USED TO UPDATE THE FIXTURE TO THE LATEST SOFTWARE. To order this device, please contact Elation Support for further details..
- ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST 323-582-3322 | Fax 323-832-9142 | support@elationlighting.com
- ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET +31 45 546 85 63 | Fax +31 45 546 85 96 | support@elationlighting.eu
ENCODER KNOBS
This device features two encoder knobs that enable quick, convenient
adjustment of various parameters. Please note that any DMX signal will
override the encoder knob inputs. The loca-tions of the two encoder knobs are
illustrated below:
- ZOOM KNOB : Manually adjust the zoom of the fixture in and out.
- CONTROL KNOB: Manually adjust dimming, CCT green, color saturation, or manual control as described in the table below.
MODE| PARAMETER| DISPLAY| RESOLUTION/ STEPS| DEFAULT
---|---|---|---|---
Dimmer| Intensity| Intensity 0-100%| 1%| 0%
Int CCT Grn
| Intensity| Intensity 0-100%| 1%| 0%
Color
Temperature
| CCT 2400-8500K| 100K| 6000K
Green Shift| GRN -100% to +100%| 1%| Neutral
Int Color Sat
| Intensity| Intensity 0-100%| 1%| 0%
Color| Virtual Color 1-53| Single Color| –
Saturation| Sat 0-100%| 1%| 100%
Manual Control
|
Select Parameter
|
[Parameter Name] 0 – 100| Intensity|
Strobe
Strobe
Red
Green
Blue
Amber
Mint
Dimmer| 0-100%| 1%| 0%
DMX TRAITS
CHANNEL|
DMX VALUES
|
FUNCTION
---|---|---
1ch Dim.| 6ch Dim. Color| 11ch St.| 18ch Ext.|
9ch CMY| 14ch CMY
Ext.
1| 1| 1| 1| 1| 1| 000 – 255| Dimmer, 0% to 100%
| 2| 2| 2| 2| 0| 000 – 255| Dimmer Fine
|
3
|
3
|
3
|
3
|
3
| | Shutter, strobe
000 – 031| Shutter closed
032 – 063| No function (shutter open)
064 – 095| Strobe effect, slow to fast
096 – 127| No function (shutter open)
128 – 159| Pulse effect in sequences
160 – 191| No function (shutter open)
192 – 223| Random strobe effect, slow to fast
224 – 255| No function (shutter open)
| | | | 4| 4| 000 – 255| Cyan, 0% to 100%
| | | | | 5| 000 – 255| Cyan Fine
| | | | 5| 6| 000 – 255| Magenta, 0% to 100%
| | | | | 7| 000 – 255| Magenta Fine
| | | | 6| 8| 000 – 255| Yellow, 0% to 100%
| | | | | 9| 000 – 255| Yellow Fine
| | 4| 4| | | 000 – 255| Red, 0% to 100%
| | | 5| | | 000 – 255| Red Fine
| | 5| 6| | | 000 – 255| Green, 0% to 100%
| | | 7| | | 000 – 255| Green Fine
| | 6| 8| | | 000 – 255| Blue, 0% to 100%
| | | 9| | | 000 – 255| Blue Fine
| | 7| 10| | | 000 – 255| Mint, 0% to 100%
| | | 11| | | 000 – 255| Mint Fine
| | 8| 12| | | 000 – 255| Amber, 0% to 100%
| | | 13| | | 000 – 255| Amber Fine
|
4
|
9
|
14
|
7
|
10
| | CTO
000 – 023| Open
024 – 085| CTO, 2400K – 8500K (see Color Temperature section
of this manual)
086 – 255| 8500K
CHANNEL|
DMX VALUES
|
FUNCTION
---|---|---
1ch Dim.| 6ch Dim. Color| 11ch St.| 18ch Ext.|
9ch CMY| 14ch CMY
Ext.
|
5
|
10
|
15
|
8
|
11
| | Color Wheel
000| Open
001 – 179| Virtual Swatch Book (see Virtual Colors section of
this manual)
| Color Scroll
180 – 201| Clockwise, fast to slow
202 – 207| Stop
208 – 229| Counter-clockwise, slow to fast
230 – 234| Open
| Random Slots
235 – 239| Fast
240 – 244| Medium
245 – 249| Slow
250 – 255| Open
| | |
16
| |
12
| | Green Shift
000| Idle
001 – 127| Full Minus Green to Neutral
128| Neutral White
129 – 255| Neutral to Full Plus Green
| | |
17
| |
13
| | Dim Modes
000 – 020| Standard
021 – 040| Stage
041 – 060| TV
061 – 080| Architectural
081 – 100| Theatre
101 – 120| Stage 2
| Dimmer Delay Time
121| 0s
122| 0.1s
123| 0.2s
124| 0.3s
125| 0.4s
126| 0.5s
127| 0.6s
128| 0.7s
CHANNEL|
DMX VALUES
|
FUNCTION
---|---|---
1ch Dim.| 6ch Dim. Color| 11ch St.| 18ch Ext.|
9ch CMY| 14ch CMY
Ext.
| | |
17
| |
13
| | Dimmer Delay time (continued)
129| 0.8s
130| 0.9s
131| 1.0s
132| 1.5s
133| 2.0s
134| 3.0s
135| 4.0s
136| 5.0s
137| 6.0s
138| 7.0s
139| 8.0s
140| 9.0s
141| 10s
142 – 255| Idle
|
6
|
11
|
18
|
9
|
14
| | Control
000 – 029| Idle
030 – 039| Fan Mode Auto
040 – 049| Fan Mode Silent
050 – 059| Fan Mode High
060 – 099| Idle
| Refresh Rate
100| 900 Hz
101| 910 Hz
102| 920 Hz
103| 930 Hz
104| 940 Hz
105| 950 Hz
106| 960 Hz
107| 970 Hz
108| 980 Hz
109| 990 Hz
110| 1000 Hz
111| 1010 Hz
CHANNEL|
DMX VALUES
|
FUNCTION
---|---|---
1ch Dim.| 6ch Dim. Color| 11ch St.| 18ch Ext.|
9ch CMY| 14ch CMY
Ext.
|
6
|
11
|
18
|
9
|
14
| | Refresh Rates (continued)
112| 1020 Hz
113| 1030 Hz
114| 1040 Hz
115| 1050 Hz
116| 1060 Hz
117| 1070 Hz
118| 1080 Hz
119| 1090 Hz
120| 1100 Hz
121| 1110 Hz
122| 1120 Hz
123| 1130 Hz
124| 1140 Hz
125| 1150 Hz
126| 1160 Hz
127| 1170 Hz
128| 1180 Hz
129| 1190 Hz
130| 1200 Hz
131| 1210 Hz
132| 1220 Hz
133| 1230 Hz
134| 1240 Hz
135| 1250 Hz
136| 1260 Hz
137| 1270 Hz
138| 1280 Hz
139| 1290 Hz
140| 1300 Hz
141| 1310 Hz
142| 1320 Hz
143| 1330 Hz
144| 1340 Hz
CHANNEL|
DMX VALUES
|
FUNCTION
---|---|---
1ch Dim.| 6ch Dim. Color| 11ch St.| 18ch Ext.|
9ch CMY| 14ch CMY
Ext.
|
6
|
11
|
18
|
9
|
14
| | Refresh Rates (continued)
145| 1350 Hz
146| 1360 Hz
147| 1370 Hz
148| 1380 Hz
149| 1390 Hz
150| 1400 Hz
151| 1410 Hz
152| 1420 Hz
153| 1430 Hz
154| 1440 Hz
155| 1450 Hz
156| 1460 Hz
157| 1470 Hz
158| 1480 Hz
159| 1490 Hz
160| 1500 Hz
161| 2500 Hz
162| 4000 Hz
163| 5000 Hz
164| 6000 Hz
165| 10,000 Hz
166| 15,000 Hz
167| 20,000 Hz
168| 25,000 Hz
169 – 200| Idle
| Dimmer Curve
201 – 210| Linear
211 – 220| Square
221 – 230| Inverse Square
231 – 240| S-Curve
241 – 255| Idle
COLOR TEMPERATURE TABLE
DMX VALUE| COLOR TEMP (K)| DMX VALUE|
COLOR TEMP (K)
---|---|---|---
024| 2400| 055| 5500
025| 2500| 056| 5600
026| 2600| 057| 5700
027| 2700| 058| 5800
028| 2800| 059| 5900
029| 2900| 060| 6000
030| 3000| 061| 6100
031| 3100| 062| 6200
032| 3200| 063| 6300
033| 3300| 064| 6400
034| 3400| 065| 6500
035| 3500| 066| 6600
036| 3600| 067| 6700
037| 3700| 068| 6800
038| 3800| 069| 6900
039| 3900| 070| 7000
040| 4000| 071| 7100
041| 4100| 072| 7200
042| 4200| 073| 7300
043| 4300| 074| 7400
044| 4400| 075| 7500
045| 4500| 076| 7600
046| 4600| 077| 7700
047| 4700| 078| 7800
048| 4800| 079| 7900
049| 4900| 080| 8000
050| 5000| 081| 8100
051| 5100| 082| 8200
052| 5200| 083| 8300
053| 5300| 084| 8400
054| 5400| 085| 8500
VIRTUAL COLORS
SPECIFICATIONS
SOURCE
- 220W 6500K RGBMA LED Engine
- 50,000 Hour Average LED Life*
- May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control and Dimming.
PHOTOMETRIC DATA
- 8,000 Total Lumen Output
- CRI 92.2
- Zoom Range 10° – 32°
- Beam Angle 9.7° – 32.2°
- Field Angle 18.7° – 49.3°
EFFECTS
- Motorized Zoom
- Electronic Dimmer and Strobe
- Variable 16-bit Dimming Modes and Curves
COLOR
- RGBMA Color Array
- CMY Emulation
- Variable CCT 2,400K – 8,500K
- Green/Magenta Shift
- Virtual Gel Swatch Book
CONTROL / CONNECTIONS
- 6 DMX Channel Modes (1 to 18 channels)
- Manual and DMX Controlled Dimmer, Color and Zoom
- Direct Access Encoder
- 4 Button Control Panel, LED Display
- RDM (Remote Device Management)
- 3/5pin DMX and IP65 Locking Power In/Out Connection
SIZE / WEIGHT
- Length: 13.5” (344mm)
- Width: 10.7” (272mm)
- Vertical Height: 15.6” (398mm)
- Weight: 16.1 lbs. (7.3kg)
ELECTRICAL / THERMAL
- AC 100-240V – 50/60Hz
- 219W Max Power Consumption
- 5°F to 113°F (-15°C to 45°C)
- BTU/hr (+/- 10%) 687.66
INCLUDED ITEMS
- Gel Frame
- Rotating 8-leaf Barn Doors
- Locking Power Cable
- APPROVALS / RATINGS
- (pending) CE | cETLus | IP20
- Specifications and documentation are subject to change without notice.
DIMENSIONAL DR AWINGS
FIXTURE ONLY
FIXTURE WITH BARNDOORS ATTACHED
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>