metabo 602028850 AS 18 L PC Compact Cordless Vacuum Cleaner Instruction Manual

June 6, 2024
metabo

metabo 602028850 AS 18 L PC Compact Cordless Vacuum Cleaner

| AS 18 L PC Compact
1) Serial Number: 02028…| AS 18 HEPA PC Compact
1) Serial Number: 02029…
---|---|---
K| –| L|
L x B x H| cm| 33,0 X 2 1 X 39,3| 33,0 X 21 X 39,3
u| v oe| 18| 18
S0| mm (in)| 32 (1,25)| 32 (1,25)
SL| m (in)| 0.5-2,5(20-98)| 0.5-2,5(20-98)
Pu1/ Pu2| m b a r ( h P a)| 110 / 1 2 0| 110 / 1 2 0
A| c m 2| 3000| 3000
V1/min1  IVl/ min2| I/min| 1380 / 2100| 1380 / 2100
D max1I  D   ma x2| m3/h| 83 / 126| 83 /126
V| I| 6| 6
LpA / KpA| dB ( A )| 69.3I2.0| 69.3I2.0
LwA / KwA| dB ( A)| 80.9I2.0| 80.9I2.0
IP|  | X4| X4

Original operating instructions

Declaration of Conformity

We, being solely responsible, hereby declare that these extraction devices, identified by type and serial number 1), meet all relevant requirements of directives 2) and standards 3). Technical documents for 4) – see page 3.

For UK only:
We as manufacturer and authorized person to compile the technical file, see 4) on page 3, hereby declare under sole responsibility that these extraction devices, identified by type and serial number 1) on page 3, fulfill all relevant provisions of following UK Regulations S.I. 2016/1091, S.I. 2008/ 1597, S.I. 2012/3032 and Designated Standards EN 60335-1:2012+A11:2014+A13:2017, EN 60335-2-69:2012, EN IEC 63000:2018.

Specified Conditions of Use

The vacuum cleaner is suitable for the vacuuming of dust, solid materials (broken glass, nails etc.), with the exception of material that is hotter than 60 °C. The vacuum cleaner is suited for vacuuming of liquids.
This device is not designed for use by persons (including children) with physical, sensory or mental disabilities, or with insufficient experience and/or knowledge, unless they are supervised by a person responsible for their safety, or have received instructions on how to use the device by this person.
Pay attention to the country-specific regulations, as well as the specifications of the material producer. This product is designed for commercial use, for example in hotels, schools, hospitals, factories, shops, offices and rental companies.
Dust containing asbestos must not be vacuumed.
Inflammable dust must not be vacuumed.
No inflammable or explosive solvents, material saturated with solvent, dust that represents an explosion hazard, liquids of any kind, thinner or material that is hotter than 60 °C are allowed to be vacuumed. This would cause an explosion and fire hazard! You are not allowed to use the device in the vicinity of inflammable gases or substances.
The user bears sole responsibility for any damage caused by inappropriate use.
Generally accepted accident prevention regulations and the enclosed safety information must be observed.

The vacuum cleaner is suited for the separation of dry, non-flammable dust, wood dust and slightly dangerous dust with workplace limit values > 1 mg/m³.

(The vacuum cleaner is suited for the separation of dry, non-flammable dust and wood dust. The particulate collective efficiency of the HEPA filter is 99.95%.

General Safety Information

Before using the device, carefully read through and familiarise yourself with all the enclosed safety information and the Operating Instructions. Keep all enclosed documentation for future reference, and ensure that you only pass on your vacuum clean together with this documentation.

Before using the device, the user must receive information, instructions and training material on using the device and the materials for which it is to be used (including details on safe disposal of the extracted material).

Special Safety Instructions

For your own protection and for the protection of your vacuum cleaner, pay attention to all parts of the text that are marked with this symbol!
Never allow children to use the device.
Children should be supervised to ensure that they do not play with the tool.
Caution! Only use accessories that are included with the device or specified operating Instructions.
The use of other accessories may impair safety.
You must not perform any work other than that described here.
In the event of misuse, improper operation or unprofessional repair work no liability shall be assumed by us for any damage incurred.
Before fitting the battery pack, make sure that the machine is switched off.
Remove the battery pack from the machine before making any adjustments, changing tools, maintaining or cleaning.
Protect battery packs from water and moisture!
Do not expose battery packs to fire!
Do not use faulty or deformed battery packs!
Do not open battery packs!
Do not touch or short circuit battery pack contacts!

A slightly acidic, flammable fluid may leak from defective Li-ion battery packs!
If battery fluid leaks out and comes into contact with your skin, rinse immediately with plenty of water. If battery fluid leaks out and comes into contact with your eyes, wash them with clean water and seek medical attention immediately!
If the machine is defective, remove the battery pack from the machine.
Do not operate devices or accessories under the following conditions:
– If the device has recognisable damage (cracks/breaks),
– Battery pack is defective,
– If there is a suspected non-visible defect (after a fall).

Only use the device with the battery cover closed. Keep the battery cover closed, even when the battery pack is not inserted.
After closing the battery pack cover, check to ensure the locking mechanism on the cover has engaged.
Do not point the nozzle, hose or tube at people or animals.
Never sit or stand on the device.
Always set up the hose so there is no danger of tripping.
Do not leave the device unattended.
The vacuum cleaner should not be used or stored outside.
IMPORTANT – This machine must only be used or stored indoors.
Acids, acetone and solvents can corrode the device components.
Prior to any servicing work, cleaning of the and after each use, switch off the device and pull out the battery pack.
Steam cleaners and high-pressure cleaners must not be used to clean the vacuum cleaner.
Mould contamination can result if the appliance is not cleaned for an extended period, especially if used in areas where foodstuffs are processed: Always clean and disinfect the vacuum cleaner immediately after use.
Never open the device outdoors during rain or storms.
Do not use the device in low (<- 20°C) or very high (>40°C) temperatures.

The device must not be operated in areas with an explosion hazard. Ensure that the vacuum cleaner is steady.
If the extracted air is discharged into the room, ensure there is an adequate air change rate (L) in the room. Observe the regulations that apply in your country.
Caution! This device contains dust that is harmful to health.

Discharge and maintenance operations (including disposal of the dust collection containers) must only be carried out by qualified specialists wearing appropriate protective clothing and equipment.

Warning – general danger!

Caution! Do not use the device until you have read the operating Instructions.

WARNING – Operating staff must be provided with appropriate instruction on how to use this vacuum cleaner.

WARNING – If foam or liquid escapes from the machine, switch off immediately.

CAUTION! Clean the water level limiting device/electrodes (25) regularly and examine it for signs of damage.

While the device is suitable for extracting substances that pose a slight threat to health, it is not appropriate for reducing wood dust in inhaled air.

Dust from material such as paint containing lead, some wood species, minerals and metal may be harmful. Contact with or inhalation of the dust may cause allergic reactions and/or respiratory diseases to the operator or bystanders.
Certain kinds of dust are classified as carcinogenic such as oak and beech dust especially in conjunction with additives for wood conditioning (chromate, wood preservative).
Notice sign for machines with dust class L:

Notice sign for machines with a filter installed from HEPA filter:

Transport of li-ion battery packs:
The shipping of Li-ion battery pack is subject to laws related to the carriage of hazardous goods (UN 3480 and UN 3481). Inform yourself of the currently valid specifications when shipping li-ion battery packs. If necessary, consult your freight forwarder. Certified packaging is available from Metabo.

Only send the battery pack if the housing is intact and no fluid is leaking. Remove the battery pack from the machine for shipping.
Prevent the contacts from shortcircuiting (e.g. by protecting them with adhesive tape).

Overview

  1. Container
  2. Snap locks
  3. Suction hose
  4. Battery cover
  5. Battery cover unlocking mechanism
  6. Toggle switch
  7. Handle
  8. Intermediate sleeve
  9. Button for filter cleaning “PressClean“ (PC)
  10. Carry strap
  11. Battery pack capacity indicator
  12. Battery pack capacity indicator button
  13. Battery pack *
  14. Battery pack release button
  15. Eyelet to attach a carry strap
  16. Suction opening
  17. Suction nozzle
  18. Upper part
  19. Suction tubes
  20. Bracket for suction tubes
  21. Fleece filter bag
  22. Fluted filter
  23. Fluted filter bracket
  24. Fluted filter screw
  25. Electrodes of stainless steel
  • not included in the scope of delivery

Initial Operation

Prior to use, check that you are using a battery pack suitable for the device.

Attaching the bracket for suction tubes

– The bracket (20) and two Philip’s head screws are in the container.
– Attach the bracket to the vacuum housing using the screws, as shown in fig. C.

Removing all accessories from the container
Use a fleece filter bag (21) (see page 2 fig. D)

Switch off the device and open the snap locks (2). Remove the upper part (18) of the device from the container (1).
Insert a fleece filter bag (21) in the container (1) as shown in fig. D, page 2. Put the upper part (18) back on and close the snap locks (2) .

Battery pack

Charge the battery pack (13) before use.
Recharge the battery pack if performance diminishes.
The ideal storage temperature is between 10°C and 30°C.
Capacity and signal indicator (11):
– Press the button (12); the LEDs indicate the charge level.
– The battery pack is almost flat and must be recharged if one LED is flashing.

Removing and inserting the battery pack

Remove: Press the battery pack release button (14) and remove the battery pack (13) .
To insert: Slide the battery pack (13) in until it engages.

Carrying strap

If required, hook the Metabo carry strap into both eyelets (15) left and right of the device. Set the carry strap to the desired length.

Carrying:
The tool must be carried only with the Metabo carry strap.
The machine must NOT be carried with the carrying strap around your neck.

The device

Switching on/off

Use the toggle switch (6) to turn the device On/Off.
Level II: High suction power
– working with a drill vacuum cleaner adapter (DDE 14, 6.30829), recommended for profiled surface such as carpets.
Level I: Medium suction power
– recommended for smooth surfaces, cordless tools with low dust generation (cordless grinders, cordless mitre saws, cordless jigsaws, etc.),.
Level 0: Off

PressClean

To clean the fluted filter (22) using a strong air flow: Put the toggel switch (6) in position II, cover Intermediate sleeve (8) or suction opening (16) with the hand and press the button (9) several times (at least 3 times).

Use

This machine is suitable for dry and wet applications

The device must not be switched on without fluted filter in place (22).

Wet vacuuming
– Remove the fleece filter bag for wet vacuuming.
– The machine switches off automatically once the maximum water level has been reached.
NOTE: if water is suctioned quickly, then you will not be able to suction as much as if water is suctioned slowly.
NOTE: the filter will get wet when suctioning water. Ensure that it has sufficient time to dry and that all components are completely dry before using the device for dry vacuuming.
The device is not switched off when the container is full for non-conductive liquids (such as emulsion drilling fluids, oils and greases).

The fill level must be monitored continuously and the container must be emptied promptly.
NOTE: if the water switch-off does not work and fluid is suctioned into the motor so that water comes out of the device, stop the device. Allow the device to dry sufficiently.
After wet vacuuming: clean the fluted filter (22) after drying it completely with the filter cleaning element.
Clean the electrodes of stainless steel with steel brush if any contaminations on them. Clean the container (1) with a moist cloth and dry it off.

Dry Vacuuming
Vacuum only with dry fluted filter (16), device and accessories. If the cartridge is damp, dust may stick and form a crust.
For dry vacuuming fleece filter bags are recommended to use.

Transport

Store the suction hose (3) on the housing as shown in Fig. A on page 2.
The upper part (18) must be securely sealed to the container (1) – check that the snap locks (2) are closed.
Set the toggle switch (6) to position “0”.

Using accessories

When using the suction nozzles and/or tube, we recommend mounting the intermediate sleeve (8) between the suction hose (3) and the suction nozzles/suction tube in use.

Cleaning

General Cleaning Instructions

Turn off the power switch and remove the battery before cleaning the device.
Clean the container (1) and accessories with water. Wipe the upper part (18) with a damp cloth.
Caution! This device contains dust that is harmful to health. Discharge and maintenance operations (including disposal of the dust collection containers) must only be carried out by qualified specialists wearing appropriate protective clothing and equipment.

Emptying the Container
For dust class only permitted for dusts with occupational exposure limits > 1mg/m3.
– Set the toggle switch (6) to position “0”
– Remove battery pack (13).
– Open the snap locks (2). Remove the upper part (18) of the device from the container (1).
– Tip out the container.

Disposing of the Fleece Filter Bag
– Set the toggle switch (6) to position “0”
– Remove battery pack (13).
– Open the snap locks (2). Remove the upper part (18) of the device from the container (1).
– Carefully remove the fleece filter bag (21) .
– Be careful with dust during disposal!
– Dispose of the vacuumed material in accordance with legal regulations.

Clean the fluted filter via PressClean
– Clean the fluted filter according to chapter 7.2

Clean the fluted filter manually
– Remove the fluted filter according to chapter 10.2
– Occasionally tap the fluted filter to remove (22) any dust that has gathered on it. If the filter is very dirty, you can clean it with water and a soft brush. Allow to filter to dry properly afterwards.

Maintenance

General instructions

Before performing any maintenance, always switch off the device and remove the battery.
Clean the device (see chapter 9.).
For maintenance by the user, the vacuum cleaner must be taken apart, cleaned and maintained, to the extent possible, without endangering maintenance staff or other people.

Preventive measures
Appropriate preventive measures include: cleaning the device before disassembly; providing local filtered forced ventilation where the vacuum cleaner is disassembled; cleaning of the maintenance area and providing suitable personal protective clothing and equipment.

When carrying out maintenance or repairs, it is essential to dispose of any contaminated objects that cannot be adequately cleaned. These objects must be disposed of using impermeable bags and in accordance with the applicable regulations for removing such waste.

Replacing the fluted filter (22)

– Clean the fluted filter again before replacement (“PressClean” see chapter 7.2)
– Set the toggle switch (6) to position “0”
– Remove battery pack (13).
– Open the snap locks (2). Remove the upper part (18) of the device from the container (1).
– Unscrew the screws (24) on the bottom of the upper part (see fig. E, page 2) so that the fluted filter (22) and filter bracket (23) can be removed.
– Seal the removed fluted filter (22) immediately in a dust-tight plastic bag and dispose of it in accordance with regulations.
– Insert a new fluted filter (22) into the fluted filter bracket (23) and use the screw (24) to attach it in the vacuum once again. Ensure proper and secure position.

Technical inspection

At least once a year, the manufacturer or a suitably qualified and trained person must carry out a dust test, e.g. to check for damage to the filter, verify that the device is air-tight.

Troubleshooting

Reduction in suction power:
See the instructions in the chapter on 9. Cleaning.

  • Is the fluted filter (22) dirty? – clean.
  • Fleece filter bag (21) full? – replace.
  • Container (1) full? – empty.
  • Nozzle, tubes or hose blocked?- clean.
  • Is the battery pack (13) weak? – Charge/replace battery pack (13)

Device will not start:

  • Is the battery pack (13) empty? – Charge/replace battery pack (13).
  • Water level detection active – empty container (1), set toggle switch (6) to “0” and restart the vacuum at level “I” or “II”.

Particles are discharged at the outlet:

  • Is the fluted filter defective? – Check the fluted filter and replace if required (see chapter 10.2).

The machine has shut down by itself:
Causes and remedies:

  • Battery pack almost flat: (the electronics prevent the battery pack form discharging totally and avoid damage). If the capacity indicator (11) flashes after pressing the battery button to display the battery capacity, then the battery pack is almost empty and must be recharged.
  • Battery pack is not inserted properly: Check and correct.
  • Long continuous overloading of the machine will activate the temperature cut-out. Leave the machine or battery pack to cool. Note: if the battery pack feels very warm, the pack will cool more quickly in an “AIR COOLED” charger.
  • Water level detection active – empty container (1), set toggle switch (6) to “0” and restart the vacuum at level “I” or “II”.
    Do not interfere with the device. Contact an authorized workshop or Metabo’s aftersales service department (see chapter 13. on Repairs).

Accessories

Only use original Metabo battery packs and Metabo accessories.
Use only accessories that fulfil the requirements and specifications listed in these operating instructions.
If you need any accessories, check with your dealer.

A. Battery packs with different capacities. Buy battery packs only with voltage suitable for your power tool.
Order no.: 625367000 18 V 4.0 Ah (LiHD)
Order no.: 625369000 18 V 8.0 Ah (LiHD)
Order no.: 625369000 18 V 5.2 Ah (Li-Ion) etc.
B. Chargers: 627378000 ASC 145, 627044000 ASC 55 etc.
C. Fluted filter for AS 18 HEPA PC Compact (630213000)
D. Fluted filter for AS18 LPC Compact (630212000)
E. 3 suction tubes and sleeve for AS 18 LPC (630168000)
F. 5 Fleece bags 6 l, AS 18 L PC Compact (630164000)
G. Stretch suction hose Ø-32mm, L 0.7-3.5m (630176000)
H. Suction nozzle 120 mm (630320000)
I. Crevice tool 200 mm (630323000)

See www.metabo.com or the catalogue for a complete range of accessories

Repairs

Repairs to devices must be carried out by qualified electricians only!
Use only original Metabo spare parts.
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. See www.metabo.com for addresses.
You can download a list of spare parts from www.metabo.com.

Environmental Protection

Do not allow battery packs to come into contact with water!
Protect the environment, and do not dispose of power tools and battery packs with household waste. Observe national regulations on separated collection and recycling of disused machines, packaging and accessories.
Discharge the battery pack in the power tool before disposal. Prevent the contacts from short-circuiting (e.g. by protecting them with adhesive tape).

Technical Specifications

Explanatory notes on the specifications on page 2.
Changes due to technological progress reserved.
K = dust class. As per EN 60335-2-69.
Lxwxh=External dimensions
U = Mains voltage
SØ = Suction hose diameter
SL = Suction hose length
pU1 = max. vacuum (at the hose)
pU2 = max. vacuum (at the blower)
A = Filter area
Vl/min1 = Air flow rate (at the hose)
Vl/min2 = Air flow rate (at the blower)
Dmax1 = max. flow rate (at the hose)
Dmax2 = max. flow rate (at the blower)
V = max. container volume
Typical A-effective perceived sound levels:
LpA = Sound pressure level
LWA = Acoustic power level
Kpa, KWA= Uncertainty
IP = protection class

During operation the noise level can exceed 80 dB(A).

Wear ear protectors!
Measured values determined in conformity with EN 60704.
=== Direct current
The technical specifications quoted are subject to tolerances (in compliance with the relevant valid standards).

Metabowerke GmbH
Metabo-Allee 1 72622 Nuertingen Germany
www.metabo.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

metabo User Manuals

Related Manuals